Jeffrey Zahn

Prof. Jeffrey Zahn

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JSJoseph J. Sherba
Joseph J. Sherba
SHStephen Hogquist
Stephen Hogquist
HLHao Lin
Hao Lin
JSJerry W. Shan
Jerry W. Shan
DSDavid I. Shreiber
David I. Shreiber
JZJeffrey Zahn
Jeffrey Zahn
Electroporation is an electro-physical, non-viral approach to perform DNA, RNA, and protein transfections of cells. Upon application of an electric field, the cell membrane is compromised, allowing the delivery of exogenous materials into cells. Cell viability and electro-transfection efficiency (eTE) are dependent on various experimental factors, including pulse waveform, vector concentration, cell type/density, and electroporation buffer properties. In this work, the effects of buffer composition on cell viability and eTE were systematically explored for plasmid DNA encoding green fluorescent protein following electroporation of 3T3 fibroblasts. A HEPES-based buffer was used in conjunction with various salts and sugars to modulate conductivity and osmolality, respectively. Pulse applications were chosen to maintain constant applied electrical energy (J) or total charge flux (C/m2). The energy of the pulse application primarily dictated cell viability, with Mg2+-based buffers expanding the reversible electroporation range. The enhancement of viability with Mg2+-based buffers led to the hypothesis that this enhancement is due to ATPase activation via re-establishing ionic homeostasis. We show preliminary evidence for this mechanism by demonstrating that the enhanced viability is eliminated by introducing lidocaine, an ATPase inhibitor. However, Mg2+ also hinders eTE compared to K+-based buffers. Collectively, the results demonstrate that the rational selection of pulsing conditions and buffer compositions are critical for the design of electroporation protocols to maximize viability and eTE.

14 August 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
SPSarah H. Park
Sarah H. Park
LLLin Lei
Lin Lei
DDDarrel D’sOuza
Darrel D’sOuza
RZRobert Zipkin
Robert Zipkin
EDEmily T DiMartini
Emily T DiMartini
JSJonathan P Singer
Jonathan P Singer
Electrospray deposition (ESD) is a promising technique for depositing micro-/nano-scale droplets and particles with high quality and repeatability. It is particularly attractive for surface coating of costly and delicate biomaterials and bioactive compounds. While high efficiency of ESD has only been successfully demonstrated for spraying surfaces larger than the spray plume, this work extends its utility to smaller surfaces. It is shown that by architecting the local “charge landscape”, ESD coatings of surfaces smaller than plume size can be achieved. Efficiency approaching 100% is demonstrated with multiple model materials, including biocompatible polymers, proteins, and bioactive small molecules, on both flat and microneedle array targets. UV-visible spectroscopy and high-performance liquid chromatography measurements validate the high efficiency and quality of the sprayed material. Here, we show how this process is an efficient and more competitive alternative to other conformal coating mechanisms, such as dip coating or inkjet printing, for micro-engineered applications.

5 November 2021 in Science Advances
Verified
Journal Article
Open access
ELEmran O. Lallow
Emran O. Lallow
NJNandita C. Jhumur
Nandita C. Jhumur
IAIjaz Ahmed
Ijaz Ahmed
SKSagar B. Kudchodkar
Sagar B. Kudchodkar
CRChristine C. Roberts
Christine C. Roberts
HLHao Lin
Hao Lin
Suction-mediated cutaneous DNA uptake yielded high in vivo efficiency and thus provides an alternative transfection platform.

17 February 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JFJoseph A. Fantuzzo
Joseph A. Fantuzzo
DRDenise A Robles
Denise A Robles
VMVincent R. Mirabella
Vincent R. Mirabella
RHRonald Hart
Ronald Hart
ZPZhiping P. Pang
Zhiping P. Pang
JZJeffrey Zahn
Jeffrey Zahn
Proper brain function relies on the precise arrangement and flow of information between diverse neural subtypes. Developing improved human cell-based models which faithfully mimic biologically relevant connectivity patterns may improve drug screening efforts given the limited success of animal models to predict safety and efficacy of therapeutics in human clinical trials. To address this need, we have developed experimental models of defined neural circuitries through the compartmentalization of neuronal cell subtypes in a 96 well plate-based platform where each microwell is divided into two compartments connected by microchannels allowing high-throughput screening (HTS) of small molecules. We demonstrate that we can generate subtype-specific excitatory and inhibitory induced neuronal cells (iNs) from human stem cell lines and that these neurons form robust functional circuits with defined connectivity. Through the use of the genetically encoded calcium indicator GCaMP6f, we monitor calcium ion transients generated during neuronal firing between and within compartments. We further demonstrate functionality of the circuit by perturbing network activity through the addition of glutamate receptor blockers using automated liquid handling. Lastly, we show that we can stimulate network activity in defined neuronal subtypes through the expression of the designer receptor exclusively activated by designer drugs (DREADD) hM3Dq and application of the ligand clozapine-N-oxide (CNO). Our results demonstrate the formation of functional neural circuits in a high-throughput platform that is compatible with compound screening, representing an important step towards developing new screening platforms for studying and ultimately treating psychiatric brain disorders that arise from disordered neural circuit function.

12 September 2018 in Developmental Dynamics
Verified
Journal Article
Open access
PDF file
JFJoseph A. Fantuzzo
Joseph A. Fantuzzo
RHRonald Hart
Ronald Hart
JZJeffrey Zahn
Jeffrey Zahn
ZPZhiping P. Pang
Zhiping P. Pang
Neuropsychiatric disorders have traditionally been difficult to study due to the complexity of the human brain and limited availability of human tissue. Induced pluripotent stem (iPS) cells provide a promising avenue to further our understanding of human disease mechanisms, but traditional 2D cell cultures can only provide a limited view of the neural circuits. To better model complex brain neurocircuitry, compartmentalized culturing systems and 3D organoids have been developed. Early compartmentalized devices demonstrated how neuronal cell bodies can be isolated both physically and chemically from neurites. Soft lithographic approaches have advanced this approach and offer the tools to construct novel model platforms, enabling circuit‐level studies of disease, which can accelerate mechanistic studies and drug candidate screening. In this review, we describe some of the common technologies used to develop such systems and discuss how these lithographic techniques have been used to advance our understanding of neuropsychiatric disease. Finally, we address other in vitro model platforms such as 3D culture systems and organoids and compare these models with compartmentalized models. We ask important questions regarding how we can further harness iPS cells in these engineered culture systems for the development of improved in vitro models. Developmental Dynamics 248:65–77, 2019.

27 February 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
MLMeng-Chen Lo
Meng-Chen Lo
SWShuwu Wang
Shuwu Wang
SSSagar Singh
Sagar Singh
VDVinod B Damodaran
Vinod B Damodaran
IAIjaz Ahmed
Ijaz Ahmed
JZJeffrey Zahn
Jeffrey Zahn
Objective . Despite the feasibility of short-term neural recordings using implantable microelectrodes, attaining reliable, chronic recordings remains a challenge. Most neural recording devices suffer from a long-term tissue response, including gliosis, at the device–tissue interface. It was hypothesized that smaller, more flexible intracortical probes would limit gliosis by providing a better mechanical match with surrounding tissue. Approach . This paper describes the in vivo evaluation of flexible parylene microprobes designed to improve the interface with the adjacent neural tissue to limit gliosis and thereby allow for improved recording longevity. The probes were coated with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)) polymer that provides temporary mechanical support for device implantation, yet degrades within 2 h post-implantation. A parametric study of probes of varying dimensions and polymer coating thicknesses were implanted in rat brains. The glial tissue response and neuronal loss were assessed from 72 h to 24 weeks post-implantation via immunohistochemistry. Main results . Experimental results suggest that both probe and polymer coating sizes affect the extent of gliosis. When an appropriate sized coating dimension (100 µ m × 100 µ m) and small probe (30 µ m × 5 µ m) was implanted, a minimal post-implantation glial response was observed. No discernible gliosis was detected when compared to tissue where a sham control consisting of a solid degradable polymer shuttle of the same dimensions was inserted. A larger polymer coating (200 µ m × 200 µ m) device induced a more severe glial response at later time points, suggesting that the initial insertion trauma can affect gliosis even when the polymer shuttle degrades rapidly. A larger degree of gliosis was also observed when comparing a larger sized probe (80 µ m × 5 µ m) to a smaller probe (30 µ m × 5 µ m) using the same polymer coating size (100 µ m × 100 µ m). There was no significant neuronal loss around the implantation sites for most device candidates except the group with largest polymer coating and probe sizes. Significance . These results suggest that: (1) the degree of mechanical trauma at device implantation and mechanical mismatches at the probe-tissue interface affect long term gliosis; (2) smaller, more flexible probes may minimize the glial response to provide improved tissue biocompatibility when used for chronic neural signal recording; and (3) some degree of glial scarring did not significantly affect neuronal distribution around the probe.