Yajuan Wang

Dr. Yajuan Wang

Shaanxi Energy Institute, Xianyang, Shaanxi, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2022 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
ZXZhao Xiaolong
Zhao Xiaolong
HDHao Dong
Hao Dong
YWYajuan Wang
Yajuan Wang
BLBo Li
Bo Li
In this paper, an aerostatic bearing model in the form of microorifice annular array is designed to explore the static performance of aerostatic bearing when the orifice diameter and working air film thickness are of the same order of magnitude. Firstly, the simulation model of the new bearing is established, the pressure distribution of the bearing gas film under the influence of the orifice diameter is analyzed by the CFD method, and the performance of the aerostatic bearing is compared with the traditional toroidal throttling method with the orifice diameter of 0.1 mm; at the same time, the effects of air supply pressure, orifice diameter, and orifice number on the static performance of the bearing under different air film thickness are analyzed; finally, a new bearing is developed, and the simulation results are verified by the experimental test. The results show that when the orifice diameter and the air film thickness are of the same order of magnitude, the maximum stiffness of the aerostatic bearing is significantly improved and the microporous throttled aerostatic bearing is more suitable for the field of high stiffness. The greater the air supply pressure, the greater the bearing capacity and stiffness of the bearing. The number of orifices has an effect on improving the bearing capacity of the bearing, but when the number of orifices is large, the effect will become less obvious. This study can provide a new theoretical reference for the design of aerostatic bearing.

24 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
YWYajuan Wang
Yajuan Wang
JZJun'an Zhang
Jun'an Zhang
ZLZhiwei Lu
Zhiwei Lu
JLJiayu Liu
Jiayu Liu
BLBo Liu
Bo Liu
HDHao Dong
Hao Dong
The regenerator plays an extremely important role in the Stirling circulation. A grid regenerator can be used for inverse Stirling machines at room temperature due to its low flow resistance. This paper proposes a hexagonal grid regenerator to theoretically explore heat transfer properties in the inverse Stirling cycle and establishes an approximate analytical model to analyze the effect mechanism of working frequency, thermal diffusivity and wall thickness on the oscillation flow. The results show that the wall thickness is one of the key factors affecting the equivalent heat transfer coefficient. Specifically, too small or too large wall thickness increases the instability of the heat transfer process. The ultimate wall thickness is determined by the equivalent heat transfer coefficient and thermal penetration depth, whose optimal value ensures not only sufficient heat exchange but also the full utilization of materials. With the increase in frequency, heat exchange performance is improved monotonously. Therefore, high–frequency operation can improve the heat exchange performance of the regenerator. In addition, an optimization criterion for the size of regenerator with the specific capacity of heat transfer as the objective parameter is proposed based on the equivalent heat transfer coefficient. The optimal parameters were obtained when relative thickness was set as 0.8 mm and the equivalent heat transfer coefficient was up to 104–105 W/m2·K indicating that the grid regenerator has broad application prospects in the inverse Stirling cycle.

6 January 2025 in Processes
Verified
Journal Article
Open access
PDF file
YWYajuan Wang
Yajuan Wang
JZJun'an Zhang
Jun'an Zhang
Junde GuoJunde Guo
Junde Guo
GZGao Zhang
Gao Zhang
JZJianhua Zhang
Jianhua Zhang
This study seeks to improve the performance of a low-temperature differential free-piston Stirling air conditioner (FPSAC). To achieve this, a novel approach is proposed, which replaces the conventional simple harmonic drive with a multi-harmonic drive. This modification aims to optimize the motion of the driving piston, bringing it closer to the ideal movement pattern. The research involves both thermodynamic and dynamic coupling simulations of the FPSAC, complemented by experimental verification of its key performance parameters. A thermodynamic model for the gas medium, employing a quasi-one-dimensional dynamic approach for compressible fluids, and a nonlinear two-dimensional vibration dynamic model for the solid piston are developed, focusing on the low-temperature differential FPSAC physical model. The finite difference method is employed to numerically simulate the entire system, including the electromagnetic thrust of the multi-harmonic-driven linear oscillating motor, fluid transport equations, and the nonlinear dynamic equations of the power and gas control pistons. Variations in displacement, velocity, and pressure for each control volume at any given time are obtained, along with the indicator and temperature–entropy diagrams after the system stabilizes. The simulation results show that, in cooling mode, assuming no heat loss or mechanical friction, the Stirling cooler operates at a frequency of 80 Hz. Using the COPsin value for the simple harmonic drive as a baseline, performance is improved by altering the driving method. Under the multi-harmonic drive, the COPc5 increased by 10.03% and COPc7 by 14.23%. In heating mode, the COP under the multi-harmonic drive improved by 0.51% for COPh5 and 2.61% for COPh7. Performance experiments were conducted on the low-temperature differential FPSAC, and the key parameter test results showed good agreement with the simulation outcomes. The maximum deviation at the trough was found to be less than 2.45%, while at the peak, the maximum error did not exceed 3.61%. When compared to the simple harmonic drive, the application of the multi-harmonic drive significantly enhances the overall efficiency of the FPSAC, demonstrating its superior performance. The simulation analysis and experimental results indicate a significant improvement in the coefficient of performance of the Stirling cooler under the multi-harmonic drive at the same power level, demonstrating that the multi-harmonic drive is an effective approach for enhancing FPSAC performance. Furthermore, it should be noted that the method proposed in this study is applicable to other types of low-temperature differential free-piston Stirling air conditioners.

5 September 2023 in Energies
Verified
Journal Article
Open access
PDF file
YWYajuan Wang
Yajuan Wang
JZJun'an Zhang
Jun'an Zhang
ZLZhiwei Lu
Zhiwei Lu
BLBo Liu
Bo Liu
HDHao Dong
Hao Dong
The main purpose of this paper is to analyze the heat transfer mechanism of a new type of regenerator with a low temperature difference and low current resistance under oscillatory flow at room temperature. Taking the single tube of the regenerator as the research object, the exact analytical solution of the radial heat transfer characteristics of the regenerator is obtained by studying its analytical model. The factors affecting the heat transfer characteristics are analyzed, and then the regenerator is optimized to improve the performance and efficiency of the regenerator system. In this study, we systematically analyzed the radial heat transfer characteristics of a regenerator under isochoric process conditions. A closed-system physical model of the incompressible isochoric process under oscillating flow was established. Then, the radial analytical solutions of pressure fluctuation, fluid velocity, fluid-solid temperature, and heat were derived in the complex number field. Furthermore, the fluid velocity, fluid-solid coupling wall temperature, heat, and equivalent heat transfer coefficient were assessed. Furthermore, the influences of frequency, inner diameter R1 of the regenerator, and different working medium and materials on the above parameters were discussed. It was found that the analysis and evaluation of fluid velocity, fluid-structure coupling wall temperature, heat, and equivalent heat transfer coefficient are helpful in understanding the dynamic characteristics of radial heat transfer in a regenerator system. Through the study of radial heat transfer under oscillating flow, it was found that the working medium, frequency, inner diameter of the regenerator, and material quality of the regenerator are helpful for the design optimization of the regenerator. Furthermore, our investigations established that the variation law of wall fluid-solid coupling temperature amplitude could be divided into three parts: the unidirectional flow part; the low-frequency part, where the temperature amplitude falls rapidly with increasing frequency; and the high-frequency part, where the temperature amplitude increases with the frequency. In addition, the variation of radial heat transfer of the fluid-solid coupling surface is similar to the changes in the temperature amplitude. We also discovered that the equivalent heat transfer coefficient of the fluid-solid surface is related to thermal conductivity of the material. Specifically, larger thermal conductivity values result in greater equivalent heat transfer coefficients. Based on the research into the radial heat transfer characteristics, the new regenerator has great application potential in the Stirling air conditioning system at room temperature.

20 November 2025 in Modelling
Verified
Journal Article
Open access
PDF file
YWYajuan Wang
Yajuan Wang
Junde GuoJunde Guo
Junde Guo
The excellent thermal performance, quiet operation, and fuel flexibility of free-piston Stirling machines enable their broad application potential in sectors such as aerospace, distributed power generation, and industrial waste heat utilization. The impact of structural parameters on the output characteristics of the free-piston Stirling engine was investigated using a parametric MATLAB model based on an isothermal thermodynamic approach. Parameters such as the dead volume ratios (χH, χK, χR), temperature ratio τ, sweep volume ratio k, piston phase angle adr, and minimum pressure angle θ were evaluated for their effects on the dimensionless power Z. The results indicate that the dead volume ratio in the cold space χK has the most significant influence on system performance, followed by the hot space χH, while the regenerator χR exhibits a comparatively weaker effect. All three parameters demonstrate the existence of optimal design intervals. The dimensionless power Z decreases monotonically with increasing dead volume ratio. Moreover, this decline is intensified at higher temperature ratios τ, indicating that the influence of dead volume becomes more significant under larger τ values. The interaction between these parameters can be described by Z=0.0037τ2−0.0045τ+0.0021. An excessively large sweep volume ratio k tends to degrade the system’s output performance. An empirical correlation between k and the dimensionless power can be established as follows Z=1.53(1−e−3.37k)+0.01. A moderate increase in the piston phase angle adr and a reduction in the minimum pressure angle θ contribute to improved system performance by enlarging the p-v diagram area and enhancing the utilization of gas expansion. The relationship between adr and the dimensionless power Z follows a linear trend, expressed as Z=0.341adr−0.2104. A well-defined functional relationship exists between the minimum pressure angle θ and the dimensionless power output Z, which can be expressed as Z=2.18×10−4θ2−0.0261θ+0.7065. A coupling regulation mechanism and design strategy have been developed to facilitate the coordinated optimization of multiple parameters in free-piston Stirling engines, which delivers theoretical guidance that is expected to support the engineering implementation of next-generation, high-performance Stirling technologies.

20 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
YWYajuan Wang
Yajuan Wang
ZZzhao kang Zhao
zhao kang Zhao
JZJun'an Zhang
Jun'an Zhang
Unlike traditional free-piston Stirling heat engines or heat pumps, the free piston Stirling air conditioning (FPSAC) is specifically designed for electric vehicle air conditioning under ambient room temperature conditions. In the FPSAC system, the displacer and the power piston are coupled through gas forces, emphasizing the importance of investing the thermodynamic–kinetic coupling characteristics. This study analyzed the damping terms within the dynamic equations of the FPSAC model and solved these equations to reveal system dynamics. By linearizing the working chamber’s pressure, the study examined the machine’s dynamic behavior, presenting solutions for amplitude and phase angle. Derived expressions for the displacement and acceleration of both the power piston and the displacer further support this analysis. The research evaluates the influence of driving force on amplitude and phase angle, alongside the impact of damping coefficients, thereby isolating thermodynamic–dynamic coupling characteristics. Control equations integrating dynamics and thermodynamics were developed, and a comprehensive system model was constructed using MATLAB(2020a)/Simulink to simulate acceleration and displacement variation in the pistons. Key findings include: (1) a positive correlation between driving force and displacer, where increased force leads to higher amplitudes; (2) a frequency of 65 Hz reveals a singularity occurs in displacer amplitude, resulting in system instability; (3) phase angle between pistons reduces to below 10° when the driving force exceeds 150 N; and (4) the power piston’s amplitude decreases with an increase in damping C1, while changes in damping C2 primarily affect the displacer’s singularity position around 65 Hz, with higher C2 values shifting the singularity to lower frequencies.