In this paper, a fiber-optic micro-cavity Mach -Zehnder interferometer is proposed and experimentally demonstrated for high-precision salinity sensing, based on the tapered multi-mode- hollow-core-multi-mode fiber structure. The excited evanescent wave field distribution is analyzed, and the quantitative relation is proved between the light intensity and taper ratio. The comprehensive tests are then performed and the experimental results show that the proposed sensor has obvious intensity modulation with the varied RI of liquid. The sensitivity as high as 796 dB/RIU is gained by the structure with the taper ratio of ~0.22, and the corresponding salinity sensitivity reaches 0.154 dB/‰ in the range from 0 to 11 ‰. Besides, owing to low temperature crosstalk and high stability, the real limit of detection of our sensor is constrained within 0.1 ‰.
In this paper, a novel hybrid-dual-microcavity (h-DMC) structure is proposed for the first time in order to achieve simultaneous salinity and temperature measurement with high sensitivity and high discrimination. The h-DMC structure is completed by proper arc-discharged large lateral-offset splicing and full-filling the temperature sensitive polymer. Based on the shared cladding, two parallel micro-cavity Mach-Zehnder interferometers are formed and respectively used to monitor the salinity and temperature variations of solution. The obtained superimposed transmission spectra are easily decoupled and precisely re-constructed due to the obvious spatial frequency difference. The average sensitivities of h-DMC can reach −2.34 nm/‰ and 5.26 nm/°C with high linearity and low measured errors, which correspond to the detection limit of 0.0085 ‰ and 0.0038 °C, respectively. Due to the merits of low cost and high yield, such an integrated fiber-optic dual-parameter sensor is very competitive and promising to high-precision marine environment monitoring.
7 November 2022 in IEEE Transactions on Instrumentation and Measurement
In this paper, a cascaded all-fiber structure is proposed and demonstrated, which includes sensing Mach-Zehnder interferometer (SMZI) based on a joint-assisted open-cavity and referencing Fabry-Perot interferometer (RFPI) based on hollow-core fiber. The temperature sensitivity of SMZI is well guaranteed and greatly improved by the Vernier effect, while the axial-strain crosstalk is obviously compressed by lengthening the open-cavity to ~2600 μm. Experimental results show that, with magnification factor of 19.04, the temperature response reaches 1.525 nm/°C and the cross sensitivity is smaller than 0.02 °C/με. Additionally, rapid time responses of less than 0.8 s are verified in the field-tests of respiratory and gas lighter. The proposed scheme presents the capability to achieve the high-precision temperature-related engineering sensing and monitoring.
26 August 2024 in IEEE Transactions on Instrumentation and Measurement
In this paper, a novel fiber-optic axial-strain sensor is proposed and demonstrated to improve the sensitivity based on the tapered-microfiber-assisted Mach-Zehnder interferometer, which is fabricated by means of the techniques of flame brush, arc-discharged large lateral offset splicing and tapering. The axial-strain response of the tapered microfiber is theoretically studied and experimentally witnessed. The tested results show the wavelength response of axial-strain is strongly related to both the diameter of taper waist and the cavity length. The five-fold enhancement is gained when the diameter is ~24 μm with an optimized cavity length. The maximum sensitivity of axial-strain reaches −31.25 pm/με with the detection limit of ~0.6 με. Our sensor has the merits of compactness, high stability and cost-efficiency, which is very promising and potential to the high precision engineering monitoring and measurements.
In this paper, a novel fiber-optic curvature sensor is proposed and demonstrated based on the taper-assisted micro-cavity (T-MOC) structure. The fabrication parameters are experimentally compared and optimized, and the comprehensive tests are performed in terms of curvature and temperature. The results show that the curvature response is effectively improved through reducing the diameter of taper waist. The maximum sensitivity reaches -7.92 nm/m -1 when the diameter is ~30 μm, with a cross-sensitivity of 0.0137 °C/m -1 . Moreover, encapsulated by polydimethylsiloxane, the T-MOC structure is used as a wearable point of care device to monitor the health status of human body. Owing to the ultralow threshold detection of 0.067m -1 , both large bending change and weak neck pulse can be precisely measured with high signal-to-noise ratio and rapid time response.
6 March 2025 in IEEE Transactions on Instrumentation and Measurement
In the realm of smart healthcare, precise monitoring of wrist arterial blood pressure holds immense clinical significance for the management of hypertension and the preventative diagnostics of cardiovascular diseases. In this article, we report a novel all-fiber wearable sensor for high-precision blood pressure monitoring based on micro-open-cavity Mach -Zehnder interferometer. Due to the assistance of taper waveguide, the sensor enduring over 60,000 tests throughout the ten-month study exhibits exceptional pulse capture and high signal-to-noise ratio, with structural integrity and flexibility. Moreover, we integrated a machine learning-based estimation model, deployed on the cloud to alleviate the computational burden. The results indicate that the proposed scheme is capable of real-time, continuous blood pressure monitoring with the accuracy of 0.04 ± 2.44 mmHg for systolic blood pressure and 0.05 ± 2.52 mmHg for diastolic blood pressure, respectively, which comply with the rigorous standards and award Grade-A rating of blood pressure prediction.