In this paper, a modified microfiber-assisted open- cavity (MMA-OC) structure is proposed by introducing two pieces of multimode fiber and a novel sub-millimeter in-line Mach-Zehnder interferometer is theoretically and experimentally completed. The cavity-length dependence of MMA-OC on axial strain sensing is characterized and the comprehensive strain tests are conducted under an optimal waist diameter. The experimental results show that the selective intensity-/wavelength- modulated strain response can be achieved by varying the cavity length. For a shorter cavity length, MMA-OC presents more than 20-dB intensity variation and near-zero wavelength drift. But an apparent and flat red-shift of fringes occurs in the structure with >1000-μm cavity length. Moreover, due to inverse feature of temperature response, the calculated cross-sensitivity is merely 0.106 μϵ/°C. And the detection resolution up to ~0.2 μϵ is gained when the cavity length is equal to 503 μm, with the measurement error of ±0.021 μϵ. Our sensor with the merits of compactness, low-cost and ease of fabrication is very promising for high-precision engineering monitoring and sensing.
In this paper, a novel micro-cavity based Mach-Zehnder interferometer is proposed by joint-assistance of microfiber and multimode fiber (MMF). The light field distribution is comprehensively investigated, and the quantitative beam expansion range and the length of MMF are obtained. Under the optimized fabrication parameters, a joint-assisted micro-cavity structure is experimentally completed and the axial strain tests are performed. The experimental results show that obvious intensity responses of fringes are exhibited in the range from 0 to $300~ {\mu \varepsilon }$ , but with gradually reduced wavelength sensitivities. It is found that a near-zero wavelength drift exists in the fringe of 1589.83 nm with the intensity sensitivity of ~0.02 dB/ ${\mu \varepsilon }$ . Besides, the corresponding temperature response is −81 pm/°C with a slight fluctuation of ~0.003 dB/°C. Such high discrimination between axial strain and temperature brings $\sim 0.5~ {\mu \varepsilon }$ detection resolution and ultra-low temperature crosstalk ( $\sim 0.15~ {\mu \varepsilon }/^{ {\circ }}\text{C}$ ), simultaneously. With the merits of high sensitivity and practicality, our sensor is very promising and potential in high-precision axial-strain related engineering monitoring and sensing.
In this paper, a thin-core fiber based in-line Mach-Zehnder interferometer is proposed and experimentally completed through symmetric core-offset splicing technique. The light field distribution of fundamental and cladding modes is investigated with varied core-offset and the state of quasi-single modal interference (QS-MI) is attained. The comprehensive tests under QS-MI state are then conducted and compared in term of liquid level sensing. Experimental results show that significant linearity- improvement is achieved in the range from 0 to 500 mm, and the responses of liquid level reach 101 pm/mm (short-range within 20-mm) and 41.8 pm/cm (long-range within 50-cm), respectively. Also owing to high response consistency, the temperature crosstalk is eliminated by means of self-differential compensation and the measured error is compressed within 0.68%. Furthermore, $\sim 16$ -fold enhancement of detection limit at least is gained through building a fiber ring-cavity laser based active sensing system. It is the first time that the issues of linearity and temperature crosstalk are simultaneously overcome in the continuous long-range liquid level measurement. With the merits of low-cost, large-scale and ease of fabrication, our scheme is very practical and promising in the engineering and applications related to liquid level sensing.
In this paper, we report a novel fiber-optic axial-strain sensor based on the bias-tapered micro-open -cavity structure. The comprehensive investigations of axial -strain response are theoretically and experimentally conducted with respects to the diameter and position of taper waist. The results show that the intensity variation is strongly related to the location of taper. When the diameter is ~30 μm, highly sensitive and linear intensity modulation (~0.043 dB/με) is gained by the bias position of ~210 μm. And for a small bias state, the wavelength response reaches 17 pm/με flatly and can be increased to 313.14 pm/με with the aid of Vernier effect. As a result, the detection resolution of ~0.2 με can be achieved in both intensity and wavelength modulated schemes. With the merits of compactness, repeatability and low cost, our sensor is very promising and potential in the high-precision axial-strain related engineering measurements.
7 November 2022 in IEEE Transactions on Instrumentation and Measurement
In this paper, a cascaded all-fiber structure is proposed and demonstrated, which includes sensing Mach-Zehnder interferometer (SMZI) based on a joint-assisted open-cavity and referencing Fabry-Perot interferometer (RFPI) based on hollow-core fiber. The temperature sensitivity of SMZI is well guaranteed and greatly improved by the Vernier effect, while the axial-strain crosstalk is obviously compressed by lengthening the open-cavity to ~2600 μm. Experimental results show that, with magnification factor of 19.04, the temperature response reaches 1.525 nm/°C and the cross sensitivity is smaller than 0.02 °C/με. Additionally, rapid time responses of less than 0.8 s are verified in the field-tests of respiratory and gas lighter. The proposed scheme presents the capability to achieve the high-precision temperature-related engineering sensing and monitoring.
26 August 2024 in IEEE Transactions on Instrumentation and Measurement
In this paper, a novel fiber-optic axial-strain sensor is proposed and demonstrated to improve the sensitivity based on the tapered-microfiber-assisted Mach-Zehnder interferometer, which is fabricated by means of the techniques of flame brush, arc-discharged large lateral offset splicing and tapering. The axial-strain response of the tapered microfiber is theoretically studied and experimentally witnessed. The tested results show the wavelength response of axial-strain is strongly related to both the diameter of taper waist and the cavity length. The five-fold enhancement is gained when the diameter is ~24 μm with an optimized cavity length. The maximum sensitivity of axial-strain reaches −31.25 pm/με with the detection limit of ~0.6 με. Our sensor has the merits of compactness, high stability and cost-efficiency, which is very promising and potential to the high precision engineering monitoring and measurements.