Laura Rojas-Rojas

Mrs. Laura Rojas-Rojas

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2023 in Life
Verified
Journal Article
Open access
PDF file
LRLaura Rojas-Rojas
Laura Rojas-Rojas
Gianluca TozziGianluca Tozzi
Gianluca Tozzi
TGTeodolito Guillen-Giron
Teodolito Guillen-Giron
This study presents a polymeric scaffold designed and manufactured to mimic the structure and mechanical compressive characteristics of trabecular bone. The morphological parameters and mechanical behavior of the scaffold were studied and compared with trabecular bone from bovine iliac crest. Its mechanical properties, such as modulus of elasticity and yield strength, were studied under a three-step monotonic compressive test. Results showed that the elastic modulus of the scaffold was 329 MPa, and the one for trabecular bone reached 336 MPa. A stepwise dynamic compressive test was used to assess the behavior of samples under various loading regimes. With microcomputed tomography (µCT), a three-dimensional reconstruction of the samples was obtained, and their porosity was estimated as 80% for the polymeric scaffold and 88% for trabecular bone. The full-field strain distribution of the samples was measured using in situ µCT mechanics and digital volume correlation (DVC). This provided information on the local microdeformation mechanism of the scaffolds when compared to that of the tissue. The comprehensive results illustrate the potential of the fabricated scaffolds as biomechanical templates for in vitro studies. Furthermore, there is potential for extending this structure and fabrication methodology to incorporate suitable biocompatible materials for both in vitro and in vivo clinical applications.

29 April 2022 in International Journal of Biomaterials
Verified
Journal Article
Open access
PDF file
LRLaura Rojas-Rojas
Laura Rojas-Rojas
AUAndrea Ulloa-Fernández
Andrea Ulloa-Fernández
SCSilvia Castro-Piedra
Silvia Castro-Piedra
WVWalter Vargas-Segura
Walter Vargas-Segura
TGTeodolito Guillen-Giron
Teodolito Guillen-Giron
An appropriate and reliable sterilization technique is crucial for tissue engineering scaffolds. Skeletal muscle scaffolds are often fabricated using microfilaments of a wide variety of polymers. One method for sterilization is 25kGy of gamma irradiation. In addition, sterilization through irradiation should administer a dose within a specific range. Radiation directly affects the chemical and mechanical properties of scaffolds. The accuracy and effects of irradiation are often not considered during sterilization procedures; however, these are important since they provide insight on whether the sterilization procedure is reliable and reproducible. This study focused on the chemical and mechanical characterization of 25kGy gamma-irradiated scaffold. The accuracy and uncertainty of the irradiation procedure were also obtained. X-ray diffraction (XRD) and differential scanning calorimetry (DSC) analyses were performed to determine whether the crystallinity of the polymer changed after irradiation and whether gamma rays influenced its thermal properties. The tensile parameters of the microfilaments were analyzed by comparing irradiated and nonirradiated scaffolds to determine whether gamma radiation changed their elastic behavior. Dose distribution and uncertainty were recorded with several dosimeters. The results showed that the irradiation process slightly affected the mechanical parameters of the scaffold; however, it did not modify its crystallinity or thermal properties. The irradiation was uniform, since the measured uncertainty was low. The scaffold was pathogen-free after 7 days; this meant sterilization was achieved. These results indicated that gamma-sterilized scaffolds were a promising material for use as a skeletal muscle analog material for tissue-engineering applications because they can be sterilized with gamma rays without changing their chemical structure and mechanical properties. This study provided the dose distribution measurement and uncertainty calculations for the sterilization procedure.

11 December 2022 in Polymers
Verified
Journal Article
Open access
PDF file
LRLaura Rojas-Rojas
Laura Rojas-Rojas
MÁMaría Laura Laura Espinoza Álvarez
María Laura Laura Espinoza Álvarez
SCSilvia Castro-Piedra
Silvia Castro-Piedra
AUAndrea Ulloa-Fernández
Andrea Ulloa-Fernández
WVWalter Vargas-Segura
Walter Vargas-Segura
TGTeodolito Guillén-Girón
Teodolito Guillén-Girón
Tissue engineering aims to develop in-vitro substitutes of native tissues. One approach of tissue engineering relies on using bioreactors combined with biomimetic scaffolds to produce study models or in-vitro substitutes. Bioreactors provide control over environmental parameters, place and hold a scaffold under desired characteristics, and apply mechanical stimulation to scaffolds. Polymers are often used for fabricating tissue-engineering scaffolds. In this study, polycaprolactone (PCL) collagen-coated microfilament scaffolds were cell-seeded with C2C12 myoblasts; then, these were grown inside a custom-built bioreactor. Cell attachment and proliferation on the scaffolds were investigated. A loading pattern was used for mechanical stimulation of the cell-seeded scaffolds. Results showed that the microfilaments provided a suitable scaffold for myoblast anchorage and that the custom-built bioreactor provided a qualified environment for the survival of the myoblasts on the polymeric scaffold. This PCL-based microfilament scaffold located inside the bioreactor proved to be a promising structure for the study of skeletal muscle models and can be used for mechanical stimulation studies in tissue engineering applications.

6 March 2023 in Revista Tecnología en Marcha
Verified
Journal Article
Open access
PDF file
LRLaura Rojas-Rojas
Laura Rojas-Rojas
TGTeodolíto Guillén-Girón
Teodolíto Guillén-Girón
Polymeric scaffolds can be fabricated as microfilaments to replicate the mechanical characteristics and biological configuration of skeletal muscles and tendons. The microfilaments used in this research were fabricated from polycaprolactone (PCL) pellets by extrusion and a spooling system without using solvents. Their mechanical properties were investigated by applying monotonic and dynamic loads on aligned grouped microfilaments using a customized grip adapter. The fabrication method was simple and produced a homogeneous microfilament with a 90 ± 3 µm diameter. The monotonic tests showed the elasticity of the microfilaments was E = 1863 ± 590 MPa, and their yield strength was σy = 242 ± 45 MPa. The dynamic load test results showed that PCL microfilaments resisted periodic loads for 5.3×105 cycles, retaining a maximum deformation of 55%. The fabricated microfilament has the potential to be used as a biomimetic polymeric scaffold suitable for mechanical stimulation because of its outstanding mechanical behavior during dynamic loading conditions.

7 August 2019 in Revista Tecnología en Marcha
Verified
Journal Article
Open access
SVStephanie Varela-Fonseca
Stephanie Varela-Fonseca
EMErnesto Montero-Zeledón
Ernesto Montero-Zeledón
LRLaura Rojas-Rojas
Laura Rojas-Rojas
AVAlejandro Varela-Fonseca
Alejandro Varela-Fonseca
DGDionisio Gutiérrez-Fallas
Dionisio Gutiérrez-Fallas
El avance tecnológico de las últimas décadas ha propiciado el desarrollo de nuevas metodologías para la caracterización de materiales de origen biológico. La espectroscopía Raman es utilizada principalmente en la caracterización de sustancias orgánicas e inorgánicas puras, sin embargo, recientemente se está utilizando para el estudio de organismos y estructuras moleculares de interés biológico. La principal dificultad en el análisis de estos materiales mediante la espectroscopía Raman es la fluorescencia que presentan las muestras al ser iluminadas con el haz de luz láser, pero mediante la técnica SERS (Surface Enhanced Raman Spectroscopy), es posible aumentar la señal Raman y reducir la interferencia de la fluorescencia. Para la aplicación de las técnicas SERS se pueden utilizar nanopartículas metálicas, principalmente oro y plata, de una adecuada distribución de tamaños. En este trabajo se presentan los resultados de la aplicación de técnica SERS a la caracterización espectroscópica del ADN de dos organismos diferentes, de un ser humano y de una bacteria del género Rickettsia, utilizando nanopartículas de oro y plata para la aplicación de la metodología.

1 July 2024 in UNED Research Journal
Verified
Journal Article
Open access
WVWalter Vargas-Segura
Walter Vargas-Segura
LRLaura Rojas-Rojas
Laura Rojas-Rojas
Introduction: Ionizing radiation is applied in various fields, and dosimetric control guarantees the quality and safety of products during the irradiation process. There is a need for dosimetric calibration procedures in industrial irradiation plants, specifically for self-shielded irradiation systems. Objective: To implement high dose dosimetry in the routine control of irradiated materials within a self-shielded irradiator. Methods: We worked with 32 dosimeters; we divided the dose range used into 8 points and used four RED Perspex dosimeters per point. We measured the specific absorbance for each dosimeter; plotted these values against dose and produced a third-degree polynomial fit as a calibration curve. Results: We obtained the calibration curve with an r2 of 0,9997. The uncertainties due to the dispersion of the dosimeters and the calibration curve were 1,39% and 0,22%, respectively, for a total uncertainty of 4,80%. This uncertainty includes dose determination with a factor coverage (k) equal to 2 for a 95% confidence interval. Conclusion: Perspex RED dosimeters can be used for routine control of irradiated products in a self-shielded irradiator system.