Lovastatin (LOV) is a drug used to treat hypercholesterolemia. Recent studies have identified its antioxidant effects and potential use in the treatment of some types of cancer. However, the low bioavailability related to its poor water solubility limits its use in solid oral dosage forms. Therefore, to improve the solubility of LOV three eutectic systems of LOV with the carboxylic acids benzoic (BEN), salicylic (SAL) and cinnamic (CIN) were obtained. Both binary phase and Tammann diagrams were constructed using differential scanning calorimetry (DSC) data of mixtures prepared from 0.1 to 1.0 molar ratios. Binary mixtures and eutectics were prepared by liquid-assisted grinding. The eutectics were further characterized by DSC and powder X-ray diffraction (PXRD), Fourier-transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM). The LOV-BEN, LOV-SAL and LOV-CIN system formed a eutectic at an LOV mole fraction of 0.19, 0.60 and 0.14, respectively. The systems exhibited improvements in LOV solubility, becoming more soluble by five-fold in the LOV-SAL system and approximately four-fold in the other two systems. Considering that the solubility enhancements and the carboxylic acids used are generally recognized as safe by the U.S. Food and Drug Administration (FDA), the LOV eutectic systems are promising materials to be used in a solubility enhancement strategy for pharmaceutical product formulation.
This study presents a polymeric scaffold designed and manufactured to mimic the structure and mechanical compressive characteristics of trabecular bone. The morphological parameters and mechanical behavior of the scaffold were studied and compared with trabecular bone from bovine iliac crest. Its mechanical properties, such as modulus of elasticity and yield strength, were studied under a three-step monotonic compressive test. Results showed that the elastic modulus of the scaffold was 329 MPa, and the one for trabecular bone reached 336 MPa. A stepwise dynamic compressive test was used to assess the behavior of samples under various loading regimes. With microcomputed tomography (µCT), a three-dimensional reconstruction of the samples was obtained, and their porosity was estimated as 80% for the polymeric scaffold and 88% for trabecular bone. The full-field strain distribution of the samples was measured using in situ µCT mechanics and digital volume correlation (DVC). This provided information on the local microdeformation mechanism of the scaffolds when compared to that of the tissue. The comprehensive results illustrate the potential of the fabricated scaffolds as biomechanical templates for in vitro studies. Furthermore, there is potential for extending this structure and fabrication methodology to incorporate suitable biocompatible materials for both in vitro and in vivo clinical applications.
The experimental conditions necessary for stabilising irbesartan (IBS) tautomers in solution and selectively obtaining the desmotropic crystal forms are presented herein.
29 April 2022 in International Journal of Biomaterials
An appropriate and reliable sterilization technique is crucial for tissue engineering scaffolds. Skeletal muscle scaffolds are often fabricated using microfilaments of a wide variety of polymers. One method for sterilization is 25kGy of gamma irradiation. In addition, sterilization through irradiation should administer a dose within a specific range. Radiation directly affects the chemical and mechanical properties of scaffolds. The accuracy and effects of irradiation are often not considered during sterilization procedures; however, these are important since they provide insight on whether the sterilization procedure is reliable and reproducible. This study focused on the chemical and mechanical characterization of 25kGy gamma-irradiated scaffold. The accuracy and uncertainty of the irradiation procedure were also obtained. X-ray diffraction (XRD) and differential scanning calorimetry (DSC) analyses were performed to determine whether the crystallinity of the polymer changed after irradiation and whether gamma rays influenced its thermal properties. The tensile parameters of the microfilaments were analyzed by comparing irradiated and nonirradiated scaffolds to determine whether gamma radiation changed their elastic behavior. Dose distribution and uncertainty were recorded with several dosimeters. The results showed that the irradiation process slightly affected the mechanical parameters of the scaffold; however, it did not modify its crystallinity or thermal properties. The irradiation was uniform, since the measured uncertainty was low. The scaffold was pathogen-free after 7 days; this meant sterilization was achieved. These results indicated that gamma-sterilized scaffolds were a promising material for use as a skeletal muscle analog material for tissue-engineering applications because they can be sterilized with gamma rays without changing their chemical structure and mechanical properties. This study provided the dose distribution measurement and uncertainty calculations for the sterilization procedure.
Titanium-based lattice structures have gained significant attention in biomedical engineering due to their potential to mimic bone-like behavior and improve implant performance. This study evaluates the performance of bio-inspired Ti64 TPMS Gyroyd and Stochastic lattice structures fabricated via Powder Bed Fusion-Laser Beam (PBF-LB), focusing on their in-vivo and ex-vivo mechanical and biological responses for biomedical applications. Utilizing an SLM 280 HL printer, samples exhibited notable geometric accuracy essential for mechanical integrity. The study highlights significant mechanical properties and geometric precision improvements achieved through chemical etching. Mechanical characterization revealed that the as-built Gyroid lattice had the highest elastic modulus (3.64 GPa) and yield strength (200.65 MPa), which improved post-etching (3.62 GPa and 219.35 MPa, respectively). The Stochastic lattice demonstrated lower yield strength values post-etching (169.81 MPa). In-vivo analyses in horse models, both structures demonstrated excellent biocompatibility and osseointegration with no adverse inflammatory responses. Ex-vivo push-out tests showed that the chemically etched Gyroid structure achieved the highest resistance to push-out force (1645.407 N) and most significant displacement (2.754 mm), indicating superior energy absorption (4920.425 mJ). These findings underscore the critical influence of microstructural design and surface treatments on implant functionality, offering novel insights into improving biomedical implant performance through lattice architecture and post-processing.
Tissue engineering endeavors to create in vitro constructs that replicate the properties of native tissue, such as skeletal muscle. This study investigated the use of mechanical stimulation to promote myogenic differentiation and enhance the functionality of bioengineered tissues. Specifically, it aimed to facilitate the differentiation of myoblasts within a three-dimensional scaffold using a defined pattern of mechanical stimulation. C2C12 cells were cultured on a collagen-coated PCL microfilament scaffold and subjected to 24 h of uniaxial static strain using a biomechanical stimulation system. Two onset times of stimulation, 72 h and 120 h post-seeding, were evaluated. Cell proliferation, myogenic marker expression, and alterations in cell morphology and orientation were assessed. Results indicate that static strain on the scaffold promoted myoblast differentiation, evidenced by morphological and molecular changes. Notably, strain initiated at 72 h induced an early differentiation stage marked by MyoD expression, whereas stimulation beginning at 120 h led to a mid-stage differentiation characterized by the co-expression of MyoD and Myogenin, culminating in myotube formation. These results highlight the critical influence of myoblast maturity at the time of strain application on the differentiation outcome. This study provides insights that could guide the optimization of mechanical stimulation protocols in tissue engineering applications.