Heebum Chun

Mr. Heebum Chun

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2024 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
CHChangheon Han
Changheon Han
HCHeebum Chun
Heebum Chun
JLJiho Lee
Jiho Lee
FZFengfeng Zhou
Fengfeng Zhou
HYHuitaek Yun
Huitaek Yun
MJMartin Jun
Martin Jun
In smart manufacturing, semiconductors play an indispensable role in collecting, processing, and analyzing data, ultimately enabling more agile and productive operations. Given the foundational importance of wafers, the purity of a wafer is essential to maintain the integrity of the overall semiconductor fabrication. This study proposes a novel automated visual inspection (AVI) framework for scrutinizing semiconductor wafers from scratch, capable of identifying defective wafers and pinpointing the location of defects through autonomous data annotation. Initially, this proposed methodology leveraged a texture analysis method known as gray-level co-occurrence matrix (GLCM) that categorized wafer images—captured via a stroboscopic imaging system—into distinct scenarios for high- and low-resolution wafer images. GLCM approaches further allowed for a complete separation of low-resolution wafer images into defective and normal wafer images, as well as the extraction of defect images from defective low-resolution wafer images, which were used for training a convolutional neural network (CNN) model. Consequently, the CNN model excelled in localizing defects on defective low-resolution wafer images, achieving an F1 score—the harmonic mean of precision and recall metrics—exceeding 90.1%. In high-resolution wafer images, a background subtraction technique represented defects as clusters of white points. The quantity of these white points determined the defectiveness and pinpointed locations of defects on high-resolution wafer images. Lastly, the CNN implementation further enhanced performance, robustness, and consistency irrespective of variations in the ratio of white point clusters. This technique demonstrated accuracy in localizing defects on high-resolution wafer images, yielding an F1 score greater than 99.3%.

1 July 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
WPWilliam Park
William Park
HCHeebum Chun
Heebum Chun
PNPhuc Nguyen
Phuc Nguyen
ChaBum LeeChaBum Lee
ChaBum Lee
This paper presents a novel positioning feedback sensor using a pair of Hall effect elements on a long-range flexure stage. The proposed Hall effect positioning feedback sensor eliminates error and uncertainty by measuring the center of the flexure stage, where a machine tool or measurement probes would take place in the industrial application. A pair of Hall effect elements were amplified in a differential configuration as the cylindrical permanent magnet enclosed in the center of the shuttle in the flexure stage that moves back and forth, generating a uniform gradient magnetic flux intensity. Nonlinear magnetic flux characteristics of a single Hall effect element were eliminated, and high-quality sensor sensitivity was achieved by differential amplification of the two Hall effect elements. The magnetic field analysis to characterize the linearity of the proposed displacement sensor was simulated using the finite element method to prove that the non-linearity of a single hall effect element may be mitigated by employing the differential amplification technique. The flexure stage was additively manufactured into a monolithic structure, and the permanent magnet was fitted into the shuttle of the flexure stage. Each Hall effect element was placed on either side of the magnet at a certain distance on the axis of shuttle movement. The proposed sensor was characterized by performing dynamic system identification of the flexure stage: open-loop response and closed-loop response. The Laser Displacement Sensor (LDS) with the 10 nm resolution was used for baseline comparison and datum line with respect to the proposed sensor. The proposed sensor responses agreed well with LDS in various dynamic inputs. The sensor response was analyzed with two differential amplification signal processing techniques. The maximum sensitivity of the two signal processing techniques was determined to be 16.55 mV/μm, and the resolution was observed as 2.5 μm. In sum, the differentially amplified Hall effect displacement sensor achieved positioning feedback with high sensitivity and linearity and minimized the sensor placement error while maintaining low cost and simple configuration.

Verified
Journal Article
Open access
PDF file
HCHeebum Chun
Heebum Chun
WPWilliam Park
William Park
JKJungsub Kim
Jungsub Kim
ChaBum LeeChaBum Lee
ChaBum Lee
This paper introduces a novel approach to in-process monitoring of the cutting temperature at the tool-chip interface (TCI). Currently, there are no tools available in the commercial market for measuring and monitoring cutting processes at the TCI region. Therefore, most of the studies about evaluating cutting temperature rely on simulation results without knowing the true temperature at the actual TCI region. In addition, recent cutting temperature measurement techniques have measurement errors occurring resulting from difficulty in estimations at the TCI region. However, the proposed method enables the measuring of cutting temperature by directly probing the localized TCI using a cutting tool coated with dielectric material. The study was conducted by utilizing the impedance characteristics of the dielectric outer layer of the cutting tool. A chemical vapor deposition (CVD) diamond coated insert that is commercially available was considered for the study to avoid wear effect. Impedance response of the dielectric layer under varying temperature conditions is assessed by Nyquist diagram using an impedance analyzer. The result of the Nyquist diagram showed temperature-dependent impedance characteristics that showed good agreement with the results from the thermal experiment which was a comparison between impedance response and elevated temperature. The impedance at the TCI for monitoring cutting temperature is measured under a turning process on a lathe using a constant current source. The impedance responses showed a significant decrease in impedance under various machining conditions which indicates a rise in cutting temperature. Moreover, different machining conditions showed different temperature profiles. The impedance responses were further characterized for depth of contact, which found that a drop in impedance corresponded to an increase in depth of contact. Therefore, the study showed that in-process monitoring of the cutting temperature is possible using an impedance model of the dielectric coating layer at the local TCI. Furthermore, with its versatility, this method is expected to measure the vibration, chatters, cutting force, and so on, as the results showed that impedance is not only sensitive to temperature but also to contact area. The application and expectation of this study is to provide real-time machining data to help end users in manufacturing industry to improve product quality, productivity, and prolonged lifespan of cutting tools.

19 March 2026 in Vacuum
Verified
Journal Article
Open access
WVWashington State University Vancouver
Washington State University Vancouver
YLYeaeun Lim
Yeaeun Lim
AIAminul Islam
Aminul Islam
HCHeebum Chun
Heebum Chun
KLKuan Lu
Kuan Lu
ChaBum LeeChaBum Lee
ChaBum Lee

9 April 2024 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
JKJungsub Kim
Jungsub Kim
HCHeebum Chun
Heebum Chun
ChaBum LeeChaBum Lee
ChaBum Lee
This paper presents a novel nondestructive testing system, magneto-eddy-current sensor (MECS), to enable surface profiling of dissimilar materials by combining magnetic sensing for ferromagnetic materials and eddy-current sensing for nonferromagnetic materials. The interactions between an electromagnetic field and nonferromagnetic surface and between a magnetic field and ferromagnetic surface were measured by the MECS. The MECS consists of a conic neodymium magnet and a copper coil wound around the magnet. Aluminum and steel surfaces bonded together were prepared to test nondestructive surface profiling of dissimilar materials by the MECS. The interactions between an electromagnetic field and aluminum surface were characterized by monitoring the impedance of the coil, and the interactions between a magnetic field and steel surface were characterized by using a force sensor attached to the neodymium magnet. The magnetic and electromagnetic effects were numerically analyzed by the finite element model. The developed MECS showed the following performance: measurement spot size 5 mm and 10 mm, dynamic measurement bandwidth (eddy-current sensing 1 kHz and magnetic sensing 200 Hz), measuring range 25 mm and 17 mm, polynomial fitting error 0.51% and 0.50%, and resolution 0.655 µm and 0.782 µm for nonferromagnetic and ferromagnetic surface profiling, respectively. This technique was also applied to surface profiling and inspection of the rivet joining sheet materials. The results showed that the MECS is capable of nondestructively monitoring and determining the riveting quality in a fast, large-area, low-cost, convenient manner.

1 March 2023 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JKJungsub Kim
Jungsub Kim
HCHeebum Chun
Heebum Chun
PNPhuc Nguyen
Phuc Nguyen
Bruce TaiBruce Tai
Bruce Tai
Hyun Jae LeeHyun Jae Lee
Hyun Jae Lee
This paper presents novel surface profilometry for both geometric part error and metallurgical material property distribution measurements of the additively manufactured and post-processed rods. The measurement system, the so-called fiber optic-eddy current sensor, consists of a fiber optic displacement sensor and an eddy current sensor. The electromagnetic coil was wrapped around the probe of the fiber optic displacement sensor. The fiber optic displacement sensor was used to measure the surface profile, and the eddy current sensor was used to measure the change in permeability of the rod under varying electromagnetic excitation conditions. The permeability of the material changes upon exposure to mechanical forces, such as compression or extension and high temperatures. The geometric part error and material property profiles of the rods were successfully extracted by using a reversal method that is conventionally used for spindle error separation. The fiber optic displacement sensor and the eddy current sensor developed in this study have a resolution of 0.286 µm and 0.00359 μr, respectively. The proposed method was applied not only to characterize the rods but also to characterize composite rods.