Zhiyong Pang

Dr. Zhiyong Pang


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2020 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
HJHan Jiao
Han Jiao
XJXinhua Jiang
Xinhua Jiang
ZPZhiyong Pang
Zhiyong Pang
XLXiaofeng Lin
Xiaofeng Lin
YHYihua Huang
Yihua Huang
LLLi Li
Li Li
Breast segmentation and mass detection in medical images are important for diagnosis and treatment follow-up. Automation of these challenging tasks can assist radiologists by reducing the high manual workload of breast cancer analysis. In this paper, deep convolutional neural networks (DCNN) were employed for breast segmentation and mass detection in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). First, the region of the breasts was segmented from the remaining body parts by building a fully convolutional neural network based on U-Net++. Using the method of deep learning to extract the target area can help to reduce the interference external to the breast. Second, a faster region with convolutional neural network (Faster RCNN) was used for mass detection on segmented breast images. The dataset of DCE-MRI used in this study was obtained from 75 patients, and a 5-fold cross validation method was adopted. The statistical analysis of breast region segmentation was carried out by computing the Dice similarity coefficient (DSC), Jaccard coefficient, and segmentation sensitivity. For validation of breast mass detection, the sensitivity with the number of false positives per case was computed and analyzed. The Dice and Jaccard coefficients and the segmentation sensitivity value for breast region segmentation were 0.951, 0.908, and 0.948, respectively, which were better than those of the original U-Net algorithm, and the average sensitivity for mass detection achieved 0.874 with 3.4 false positives per case.

1 January 2015 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
ZPZhiyong Pang
Zhiyong Pang
DZDongmei Zhu
Dongmei Zhu
DCDihu Chen
Dihu Chen
LLLi Li
Li Li
YSYuanzhi Shao
Yuanzhi Shao
This study established a fully automated computer-aided diagnosis (CAD) system for the classification of malignant and benign masses via breast magnetic resonance imaging (BMRI). A breast segmentation method consisting of a preprocessing step to identify the air-breast interfacing boundary and curve fitting for chest wall line (CWL) segmentation was included in the proposed CAD system. The Chan-Vese (CV) model level set (LS) segmentation method was adopted to segment breast mass and demonstrated sufficiently good segmentation performance. The support vector machine (SVM) classifier with ReliefF feature selection was used to merge the extracted morphological and texture features into a classification score. The accuracy, sensitivity, and specificity measurements for the leave-half-case-out resampling method were 92.3%, 98.2%, and 76.2%, respectively. For the leave-one-case-out resampling method, the measurements were 90.0%, 98.7%, and 73.8%, respectively.

15 October 2024 in Academic Radiology
Verified
Journal Article
Closed access
HGHaitian Gui
Haitian Gui
TSTao Su
Tao Su
XJXinhua Jiang
Xinhua Jiang
LLLi Li
Li Li
LXLang Xiong
Lang Xiong
ZPZhiyong Pang
Zhiyong Pang

20 June 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
DTDongdong Teng
Dongdong Teng
LLLilin Liu
Lilin Liu
YZYueli Zhang
Yueli Zhang
ZPZhiyong Pang
Zhiyong Pang
SCShengqian Chang
Shengqian Chang
BWBiao Wang
Biao Wang
A holographic display system combining the spatial- and time-multiplexing together in one system is proposed. The system is constructed by multiple planar aligned spatial-light-modulators (SLMs). A shiftable cylindrical lens is introduced in to build up an “equivalent SLM” by seamlessly linked horizontal images of the SLMs, which are tiled in a time-sequential manner. The proposed system can realize wide horizontal-viewing-angle holographic three-dimensional (3D) display through the “equivalent SLM”, but bear with low requirements on the number and frame rate of SLMs, and the numerical aperture of the optical system. In the proposed system, only one parallel incident beam is needed, leading to a simplified optical structure. Using two 60Hz phase SLMs, a 3D display with a horizontal viewing angle (VA) of 27.5° is implemented experimentally.

1 December 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
HGHaitian Gui
Haitian Gui
HJHan Jiao
Han Jiao
LLLi Li
Li Li
XJXinhua Jiang
Xinhua Jiang
Tao SuTao Su
Tao Su
ZPZhiyong Pang
Zhiyong Pang
AI-based breast cancer detection can improve the sensitivity and specificity of detection, especially for small lesions, which has clinical value in realizing early detection and treatment so as to reduce mortality. The two-stage detection network performs well; however, it adopts an imprecise ROI during classification, which can easily include surrounding tumor tissues. Additionally, fuzzy noise is a significant contributor to false positives. We adopted Faster RCNN as the architecture, introduced ROI aligning to minimize quantization errors and feature pyramid network (FPN) to extract different resolution features, added a bounding box quadratic regression feature map extraction network and three convolutional layers to reduce interference from tumor surrounding information, and extracted more accurate and deeper feature maps. Our approach outperformed Faster R-CNN, Mask R-CNN, and YOLOv9 in breast cancer detection across 485 internal cases. We achieved superior performance in mAP, sensitivity, and false positive rate ((0.752, 0.950, 0.133) vs. (0.711, 0.950, 0.200) vs. (0.718, 0.880, 0.120) vs. (0.658, 0.680, 405)), which represents a 38.5% reduction in false positives compared to manual detection. Additionally, in a public dataset of 220 cases, our model also demonstrated the best performance. It showed improved sensitivity and specificity, effectively assisting doctors in diagnosing cancer.

1 October 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZPZhiyong Pang
Zhiyong Pang
CWChuansheng Wei
Chuansheng Wei
DTDongdong Teng
Dongdong Teng
DCDihu Chen
Dihu Chen
HTHongzhou Tan
Hongzhou Tan
The localization of eye centers is a very useful cue for numerous applications like face recognition, facial expression recognition, and the early screening of neurological pathologies. Several methods relying on available light for accurate eye-center localization have been exploited. However, despite the considerable improvements that eye-center localization systems have undergone in recent years, only few of these developments deal with the challenges posed by the profile (non-frontal face). In this paper, we first use the explicit shape regression method to obtain the rough location of the eye centers. Because this method extracts global information from the human face, it is robust against any changes in the eye region. We exploit this robustness and utilize it as a constraint. To locate the eye centers accurately, we employ isophote curvature features, the accuracy of which has been demonstrated in a previous study. By applying these features, we obtain a series of eye-center locations which are candidates for the actual position of the eye-center. Among these locations, the estimated locations which minimize the reconstruction error between the two methods mentioned above are taken as the closest approximation for the eye centers locations. Therefore, we combine explicit shape regression and isophote curvature feature analysis to achieve robustness and accuracy, respectively. In practical experiments, we use BioID and FERET datasets to test our approach to obtaining an accurate eye-center location while retaining robustness against changes in scale and pose. In addition, we apply our method to non-frontal faces to test its robustness and accuracy, which are essential in gaze estimation but have seldom been mentioned in previous works. Through extensive experimentation, we show that the proposed method can achieve a significant improvement in accuracy and robustness over state-of-the-art techniques, with our method ranking second in terms of accuracy. According to our implementation on a PC with a Xeon 2.5Ghz CPU, the frame rate of the eye tracking process can achieve 38 Hz.