Wendell Coltro

Prof. Wendell Coltro


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Analytica Chimica Acta
Verified
Journal Article
Closed access
WAWilliam De Araujo
William De Araujo
TCThiago M.G. Cardoso
Thiago M.G. Cardoso
RRRaquel G. da Rocha
Raquel G. da Rocha
MSMário H.P. Santana
Mário H.P. Santana
Rodrigo A. A. MunozRodrigo A. A. Munoz
Rodrigo A. A. Munoz
WCWendell Coltro
Wendell Coltro

13 August 2014 in RSC Advances
Verified
Journal Article
Closed access
PDF file
PGPaulo de Tarso Garcia
Paulo de Tarso Garcia
TCThiago Miguel Garcia Cardoso
Thiago Miguel Garcia Cardoso
Carlos GarciaCarlos Garcia
Carlos Garcia
Emanuel CarrilhoEmanuel Carrilho
Emanuel Carrilho
WCWendell Coltro
Wendell Coltro
This paper describes the development and use of a handheld and lightweight stamp for the production of microfluidic paper-based analytical devices (μPADs). We also chemically modified the paper surface for improved colorimetric measurements. The design of the microfluidic structure has been patterned in a stamp, machined in stainless steel. Prior to stamping, the paper surface was oxidized to promote the conversion of hydroxyl into aldehyde groups, which were then chemically activated for covalent coupling of enzymes. Then, a filter paper sheet was impregnated with paraffin and sandwiched with a native paper (n-paper) sheet, previously oxidized. The metal stamp was preheated at 150 °C and then brought in contact with the paraffined paper (p-paper) to enable the thermal transfer of the paraffin to the n-paper, thus forming the hydrophobic barriers under the application of a pressure of ca. 0.1 MPa for 2 s. The channel and barrier widths measured in 50 independent μPADs exhibited values of 2.6 ± 0.1 and 1.4 ± 0.1 mm, respectively. The chemical modification for covalent coupling of enzymes on the paper surface also led to improvements in the colour uniformity generated inside the sensing area, a known bottleneck in this technology. The relative standard deviation (RSD) values for glucose and uric acid (UA) assays decreased from 40 to 10% and from 20 to 8%, respectively. Bioassays related to the detection of glucose, UA, bovine serum albumin (BSA), and nitrite were successfully performed in concentration ranges useful for clinical assays. The semi-quantitative analysis of all four analytes in artificial urine samples revealed an error smaller than 4%. The disposability of μPADs, the low instrumental requirements of the stamp-based fabrication, and the improved colour uniformity enable the use of the proposed devices for the point-of-care diagnostics or in limited resources settlements.

27 May 2016 in The Analyst
Verified
Journal Article
Closed access
PDF file
EGEllen F. M. Gabriel
Ellen F. M. Gabriel
PGPaulo de Tarso Garcia
Paulo de Tarso Garcia
TCThiago M. G. Cardoso
Thiago M. G. Cardoso
FLFlávio Lopes
Flávio Lopes
FMFelipe T. Martins
Felipe T. Martins
WCWendell Coltro
Wendell Coltro
This paper describes the modification of microfluidic paper-based analytical devices (μPADs) with chitosan to improve the analytical performance of colorimetric measurements associated with enzymatic bioassays.

3 March 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
EEElizabeth Evans
Elizabeth Evans
EGEllen Flávia Moreira Gabriel
Ellen Flávia Moreira Gabriel
WCWendell Coltro
Wendell Coltro
Carlos GarciaCarlos Garcia
Carlos Garcia
A systematic investigation was conducted to study the effect of paper type on the analytical performance of a series of microfluidic paper-based analytical devices (μPADs) fabricated using a CO2 laser engraver.

2 April 2019 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
LCLucas F. de Castro
Lucas F. de Castro
SFSoraia V. de Freitas
Soraia V. de Freitas
LDLucas C. Duarte
Lucas C. Duarte
PSPedro Paulo Chaves Souza
Pedro Paulo Chaves Souza
Thiago PaixaoThiago Paixao
Thiago Paixao
WCWendell Coltro
Wendell Coltro

20 August 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
EEElizabeth Evans
Elizabeth Evans
EGEllen Flávia Moreira Gabriel
Ellen Flávia Moreira Gabriel
TBTomás E. Benavidez
Tomás E. Benavidez
WCWendell Coltro
Wendell Coltro
Carlos GarciaCarlos Garcia
Carlos Garcia
The modification of μPADs with SiO 2 NPs provides enhanced color intensity and minimal color gradient.