Liyuan Zhang

Dr. Liyuan Zhang

California Institute of Technology, Pasadena, California, USA
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2025 in Physical Review D
Verified
Journal Article
Closed access
ECE. Capote
E. Capote
WJW. Jia
W. Jia
NAN. Aritomi
N. Aritomi
MNMasayuki Nakano
Masayuki Nakano
VXV. Xu
V. Xu
MZM. E. Zucker
M. E. Zucker

20 September 2024 in Science
Verified
Journal Article
Closed access
WJWenxuan Jia
Wenxuan Jia
VXVictoria Xu
Victoria Xu
KKKevin Kuns
Kevin Kuns
MNMasayuki Nakano
Masayuki Nakano
LBLisa Barsotti
Lisa Barsotti
MZM. E. Zucker
M. E. Zucker
The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot be simultaneously measured with arbitrary precision, giving rise to an apparent limitation known as the standard quantum limit (SQL). Gravitational-wave detectors use photons to continuously measure the positions of freely falling mirrors and so are affected by the SQL. We investigated the performance of the Laser Interferometer Gravitational-Wave Observatory (LIGO) after the experimental realization of frequency-dependent squeezing designed to surpass the SQL. For the LIGO Livingston detector, we found that the upgrade reduces quantum noise below the SQL by a maximum of three decibels between 35 and 75 hertz while achieving a broadband sensitivity improvement, increasing the overall detector sensitivity during astrophysical observations.

21 April 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CHChen Hu
Chen Hu
FYFan Yang
Fan Yang
LZLiyuan Zhang
Liyuan Zhang
RZRen-Yuan Zhu
Ren-Yuan Zhu
JKJon Kapustinsky
Jon Kapustinsky
ZWZhehui Wang
Zhehui Wang
One crucial issue for the application of scintillation crystals in future high-energy physics experiments is radiation damage in a severe radiation environment, such as the high luminosity large hadron collider. While radiation damage induced by ionization dose in inorganic scintillators is well understood, investigations are on-going to understand radiation damage induced by hadrons, including both charged hadrons and neutrons. Aiming at understanding neutron induced radiation damage in fast inorganic scintillators, LYSO/LFS, BaF2 and PWO crystals were irradiated at Los Alamos Neutron Science Center by a combination of particles, including neutrons, protons and γ-rays. The results indicate that LYSO/LFS and BaF2 crystal plates are radiation hard up to a 1 MeV equivalent neutrons fluence of 9 ×1015 neq/cm2, but not PWO, and the neutron-induced radiation damage in LYSO crystals is a factor of ten less than protons.

25 August 2022 in Instruments
Verified
Journal Article
Open access
PDF file
TAThomas Anderson
Thomas Anderson
TBThomas Barbera
Thomas Barbera
BCBradley Cox
Bradley Cox
PDPaul Debbins
Paul Debbins
MDMaxwell Dubnowski
Maxwell Dubnowski
RZRen-Yuan Zhu
Ren-Yuan Zhu
To address the challenges of providing high-performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCC-hh environments), we conducted R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we focused our attention on ultra-compact radiation-hard EM calorimeters based on modular structures (RADiCAL modules) consisting of alternating layers of the very dense absorber and scintillating plates, read out via radiation hard wavelength shifting (WLS) solid fiber or capillary elements to photosensors positioned either proximately or remotely, depending upon their radiation tolerance. RADiCAL modules provide the capability to measure simultaneously and with high precision the position, energy and timing of EM showers. This paper provides an overview of the instrumentation and photosensor R&D associated with the RADiCAL program.

5 March 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CHChen Hu
Chen Hu
LZLiyuan Zhang
Liyuan Zhang
RZRen-Yuan Zhu
Ren-Yuan Zhu
JCJunfeng Chen
Junfeng Chen
DDDongzhou Ding
Dongzhou Ding
MZMingrong Zhang
Mingrong Zhang
Gigahertz hard X-ray imaging presents an unprecedented challenge to both timing and spatial resolutions for inorganic scintillator-based front imagers. A beam test with 30 keV X-rays from the APS showed that 5 mm BaF2 plates resolve well 30 keV X-ray septuplets of 27 ps width and 2.83 ns spacing. Pixelated crystal screens with a pitch down to 400 μm were fabricated by mechanic slicing for BaF2, BaF2:Y and LYSO crystals. Their spatial resolution and detection efficiency for hard X-rays are defined by the pitch and thickness, respectively. Thicker monolithic crystal screens show poorer spatial resolution, which may be improved using a small optical aperture with a loss in both efficiency and dynamic range for hard X-rays. Future plans include pursuing smaller crystal pitches by laser slicing and R&D on novel ultrafast inorganic scintillators.

1 May 2023 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
BBB. K. Berger
B. K. Berger
JAJ. S. Areeda
J. S. Areeda
JBJ. D. Barker
J. D. Barker
AEA. Effler
A. Effler
EGE. Goetz
E. Goetz
JZJ. Zweizig
J. Zweizig
Advanced LIGO and Advanced Virgo have detected gravitational waves from astronomical sources to open a new window on the Universe. To explore this new realm requires an exquisite level of detector sensitivity, meaning that the much stronger signal from instrumental and environmental noise must be rejected. Selected examples of unwanted noise in Advanced LIGO are presented. The initial focus is on how the existence of this noise (characterized by particular frequencies or time intervals) was discovered. Then, a variety of methods are used to track down the source of the noise, e.g., a fault within the instruments or coupling from an external source. The ultimate goal of this effort is to mitigate the noise by either fixing equipment or by augmenting methods to suppress the coupling to the environment.