Meng Jiang

Mrs. Meng Jiang

Department of Computer and Electrical Engineering, Mid Sweden University, Sundsvall, Västernorrland, Sweden
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Meng JiangMeng Jiang
Meng Jiang
CNChibuzo Joseph Nnonyelu
Chibuzo Joseph Nnonyelu
JLJan Lundgren
Jan Lundgren
GTGöran Thungström
Göran Thungström
MSMårten Sjöström
Mårten Sjöström
In modern applications such as robotics, autonomous vehicles, and speaker localization, the computational power for sound source localization applications can be limited when other functionalities get more complex. In such application fields, there is a need to maintain high localization accuracy for several sound sources while reducing computational complexity. The array manifold interpolation (AMI) method applied with the Multiple Signal Classification (MUSIC) algorithm enables sound source localization of multiple sources with high accuracy. However, the computational complexity has so far been relatively high. This paper presents a modified AMI for uniform circular array (UCA) that offers reduced computational complexity compared to the original AMI. The complexity reduction is based on the proposed UCA-specific focusing matrix which eliminates the calculation of the Bessel function. The simulation comparison is done with the existing methods of iMUSIC, the Weighted Squared Test of Orthogonality of Projected Subspaces (WS-TOPS), and the original AMI. The experiment result under different scenarios shows that the proposed algorithm outperforms the original AMI method in terms of estimation accuracy and up to a 30% reduction in computation time. An advantage offered by this proposed method is the ability to implement wideband array processing on low-end microprocessors.

1 May 2020
Verified
Conference Paper
Closed access
Meng JiangMeng Jiang
Meng Jiang
JLJan Lundgren
Jan Lundgren
SPShahab Pasha
Shahab Pasha
Marco CarratùMarco Carratù
Marco Carratù
CLConsolatina Liguori
Consolatina Liguori
GTGoran Thungstrom
Goran Thungstrom
Indoor localization has been a popular research subject in recent years. Usually, object localization using sound involves devices on the objects, acquiring data from stationary sound sources, or by localizing the objects with external sensors when the object generates sounds. Indoor localization systems using microphones have traditionally also used systems with several microphones, setting the limitations on cost efficiency and required space for the systems. In this paper, the goal is to investigate whether it is possible for a stationary system to localize a silent object in a room, with only one microphone and ambient noise as information carrier. A subtraction method has been combined with a fingerprint technique, to define and distinguish the noise absorption characteristic of the silent object in the frequency domain for different object positions. The absorption characteristics of several positions of the object is taken as comparison references, serving as fingerprints of known positions for an object. With the experiment result, the tentative idea has been verified as feasible, and noise signal based lateral localization of silent objects can be achieved.

16 May 2022
Verified
Conference Paper
Closed access
Meng JiangMeng Jiang
Meng Jiang
CNChibuzo Joseph Nnonyelu
Chibuzo Joseph Nnonyelu
JLJan Lundgren
Jan Lundgren
MSMarten Sjostrom
Marten Sjostrom
GTGoran Thungstrom
Goran Thungstrom
SGShan Gao
Shan Gao
The sound source localization technology brings the possibility of mapping the sound source positions. In this paper, angle-of-arrival (AOA) has been chosen as the method for achieving sound source localization in an indoor enclosed environment. The dynamic environment and reverberations bring a challenge for AOA-based systems for such applications. By the acknowledgement of microphone directionality, the cardioid-directional microphone systems have been chosen for the localization performance comparison with omni-directional microphone systems, in order to investigate which microphone is superior in AOA indoor sound source localization. To reduce the hardware complexity, the number of microphones used during the experiment has been limited to 4. A localization improvement has been proposed with a weighting factor. The comparison has been done for both types of microphones with 3 different array manifolds under the same system setup. The comparison shows that the cardioid-directional microphone system has an overall higher accuracy.

8 July 2024
Verified
Conference Paper
Closed access
CNChibuzo Joseph Nnonyelu
Chibuzo Joseph Nnonyelu
Meng JiangMeng Jiang
Meng Jiang
MAMarianthi Adamopoulou-Soulantika
Marianthi Adamopoulou-Soulantika
JLJan Lundgren
Jan Lundgren
Direction of arrival estimation using the spherical microphone array usually requires a search in the whole 3-dimensional space, hence computationally demanding. This work presents a machine learning approach to sectorizing the 3-dimensional space, as an intermediate step for direction-of-arrival estimation using spherical microphone array. A new feature based on the outer product of spherical harmonic vectors was proposed for the classification. This spherical harmonic matrix nominally offers lower dimensionality compared to the commonly used covariance matrix of received data. The dimension of the input matrix was further reduced using the neighborhood component analysis. The extracted features were then used to train a support vector machine (SVM), 2-layer multilayer perceptron (MLP) and a convolutional neural network (CNN) for classification purposes. The results show that the models were able to classify the spherical sector with up to 90 % accuracy for all models and number of sectors under consideration. Also, the MLP and CNN trained with simulated samples were able to accurately classify samples from real data that were not included in training samples.

1 March 2023 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
CNChibuzo Joseph Nnonyelu
Chibuzo Joseph Nnonyelu
Meng JiangMeng Jiang
Meng Jiang
JLJan Lundgren
Jan Lundgren
The spherical microphone array can be uneconomical for applications where the sources arrive only from a known section of the sphere. For this reason, the spherical-sector harmonics was developed for processing spherical sector array. The orthonormal spherical sector harmonics (SSH) basis functions which accounts for the discontinuity arising from sectioning the sphere have been developed and shown to work for the array of omnidirectional microphones. In this work, the SSH basis functions are applied to far-field wideband sound source localization using spherical-sector array of first-order directional microphones (cardioid microphones). The array manifold interpolation method is used to produce the steered covariance matrix and the MUSIC algorithm applied for the direction of arrival estimation. The root-mean-square error performance of this spherical-sector array of the first-order cardioid microphones is compared against that of the omnidirectional microphones for different directions and signal-to-noise ratio.

27 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CNChibuzo Joseph Nnonyelu
Chibuzo Joseph Nnonyelu
Meng JiangMeng Jiang
Meng Jiang
MAMarianthi Adamopoulou-Soulantika
Marianthi Adamopoulou-Soulantika
JLJan Lundgren
Jan Lundgren
Traditional spherical sector microphone arrays using omnidirectional microphones face limitations in modal strength and spatial resolution, especially within spherical sector configurations. This study aims to enhance array performance by developing a spherical sector array employing first-order cardioid microphones. A model based on spherical sector harmonic (SSH) functions is introduced to extend the benefits of spherical harmonics to sector arrays. Modal strength analysis demonstrates that cardioid microphones in open spherical sectors enhance nonzero-order strengths and eliminate the nulls associated with spherical Bessel functions. We find that the spatial resolution of spherical cap arrays depends on the array’s maximum order and the limiting polar angle, but is independent of the microphone gain pattern. We assess direction-of-arrival (DOA) estimation performance for coherent wideband sources using the array manifold interpolation method, and compare cardioid and omnidirectional arrays through simulations in both open and rigid hemispherical configurations. The results indicate that cardioid arrays outperform omnidirectional ones on DOA estimation tasks, with performance improving alongside increased microphone directivity in the open hemispherical configuration. Specifically, hypercardioid microphones yielded the best results in the open configuration, while subcardioid microphones (without nulls) were optimal in rigid configurations. These findings demonstrate that spherical sector arrays of first-order cardioid microphones offer improved modal strength and DOA estimation capabilities over traditional omnidirectional arrays, providing significantly enhancing performance in spherical sector array processing.