Panu Mustakallio

Prof. Dr. Panu Mustakallio

Halton Oy, Helsinki, Uusimaa, Finland
+1
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JTJulian Tang
Julian Tang
ANAndre Nicolle
Andre Nicolle
JPJovan Pantelic
Jovan Pantelic
CKChristian A. Klettner
Christian A. Klettner
RSRuikun Su
Ruikun Su
Kwok Wai ThamKwok Wai Tham
Kwok Wai Tham
Hospital isolation rooms are vital for the containment (when under negative pressure) of patients with, or the protection (when under positive pressure) of patients, from airborne infectious agents. Such facilities were essential for the management of highly contagious patients during the 2003 severe acute respiratory syndrome (SARS) outbreaks and the more recent 2009 A/H1N1 influenza pandemic. Many different types of door designs are used in the construction of such isolation rooms, which may be related to the space available and affordability. Using colored food dye as a tracer, the qualitative effects of door-opening motions on the dissemination of potentially contaminated air into and out of a single isolation room were visualized and filmed using Reynolds-number-equivalent, small-scale, water-tank models fitted with programmable door-opening and moving human figure motions. Careful scaling considerations involved in the design and construction of these water-tank models enabled these results to be accurately extrapolated to the full-scale situation. Four simple types of door design were tested: variable speed single and double, sliding and hinged doors, in combination with the moving human figure. The resulting video footage was edited, synchronized and presented in a series of split-screen formats. From these experiments, it is clear that double-hinged doors pose the greatest risk of leakage into or out of the room, followed by (in order of decreasing risk) single-hinged, double-sliding and single-sliding doors. The relative effect of the moving human figure on spreading any potential contamination was greatest with the sliding doors, as the bulk airflows induced were large relative to those resulting from these door-opening motions. However, with the hinged doors, the airflows induced by these door-opening motions were significantly greater. Further experiments involving a simulated ventilated environment are required, but from these findings alone, it appears that sliding-doors are far more effective for hospital isolation room containment.

1 May 2016 in Building and Environment
Verified
Journal Article
Closed access
PMPanu Mustakallio
Panu Mustakallio
ZBZhecho Bolashikov
Zhecho Bolashikov
KKKalin Kostov
Kalin Kostov
AMArsen Melikov
Arsen Melikov
Risto KosonenRisto Kosonen
Risto Kosonen

1 May 2005 in Building and Environment
Verified
Journal Article
Closed access
GEG. Einberg
G. Einberg
KHK. Hagström
K. Hagström
PMPanu Mustakallio
Panu Mustakallio
HKH. Koskela
H. Koskela
SHS. Holmberg
S. Holmberg

1 January 2021 in Building and Environment
Verified
Journal Article
Closed access
Weixin ZhaoWeixin Zhao
Weixin Zhao
SKSimo Kilpeläinen
Simo Kilpeläinen
RKRisto Kosonen
Risto Kosonen
JJJuha Jokisalo
Juha Jokisalo
SLSami Lestinen
Sami Lestinen
PMPanu Mustakallio
Panu Mustakallio

1 October 2017 in Building and Environment
Verified
Journal Article
Closed access
PMPanu Mustakallio
Panu Mustakallio
ZBZhecho Bolashikov
Zhecho Bolashikov
LRLauris Rezgals
Lauris Rezgals
ALAleksandra Lipczyńska
Aleksandra Lipczyńska
AMArsen Melikov
Arsen Melikov
Risto KosonenRisto Kosonen
Risto Kosonen