Pacôme  Delva

Pacôme Delva

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2017 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
PDPacôme Delva
Pacôme Delva
JLJ. Lodewyck
J. Lodewyck
SBS. Bilicki
S. Bilicki
EBE. Bookjans
E. Bookjans
GVG. Vallet
G. Vallet
PGP. Gill
P. Gill
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson-Mansouri-Sexl parameter |α|≲1.1×10−8, quantifying a violation of time dilation, thus improving by a factor of around 2 the best known constraint obtained with Ives-Stilwell type experiments, and by 2 orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this Letter will improve by orders of magnitude in the near future.

4 December 2018 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
PDPacôme Delva
Pacôme Delva
NPN. Puchades
N. Puchades
ESE. Schönemann
E. Schönemann
FDF. Dilssner
F. Dilssner
CCC. Courde
C. Courde
PWP. Wolf
P. Wolf
We report on a new test of the gravitational redshift and thus of local position invariance, an integral part of the Einstein equivalence principle, which is the foundation of general relativity and all metric theories of gravitation. We use data spanning 1008 days from two satellites of Galileo, Europe’s global satellite navigation system, which were launched in 2014, but accidentally delivered on elliptic rather than circular orbits. The resulting modulation of the gravitational redshift of the onboard atomic clocks allows the redshift determination with high accuracy. Additionally, specific laser ranging campaigns to the two satellites have enabled a good estimation of systematic effects related to orbit uncertainties. Together with a careful conservative modeling and control of other systematic effects we measure the fractional deviation of the gravitational redshift from the prediction by general relativity to be (0.19±2.48)×10−5 at 1 sigma, improving the best previous test by a factor 5.6. To our knowledge, this represents the first reported improvement on one of the longest standing results in experimental gravitation, the Gravity Probe A hydrogen maser rocket experiment back in 1976.

1 September 2020 in New Journal of Physics
Verified
Journal Article
Open access
BRBenjamin Roberts
Benjamin Roberts
PDPacôme Delva
Pacôme Delva
AAA Al-Masoudi
A Al-Masoudi
AAA Amy-Klein
A Amy-Klein
CBC Bærentsen
C Bærentsen
PWP Wolf
P Wolf
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation to |δα/α| < 5 × 10−17 for transients of duration 103 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (≳104 km) objects.

4 September 2008 in Experimental Astronomy
Verified
Journal Article
Closed access
PDF file
PWP. Wolf
P. Wolf
CBCh. J. Bordé
Ch. J. Bordé
ACA. Clairon
A. Clairon
LDL. Duchayne
L. Duchayne
ALA. Landragin
A. Landragin
KSK. Sengstock
K. Sengstock

12 December 2017 in Journal of Geodesy
Verified
Journal Article
Open access
PDF file
HDHeiner Denker
Heiner Denker
Timmen LudgerTimmen Ludger
Timmen Ludger
CVChristian Voigt
Christian Voigt
SWStefan Weyers
Stefan Weyers
EPEkkehard Peik
Ekkehard Peik
GPGérard Petit
Gérard Petit
The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in \(10^{18}\) level. Comparisons between earthbound clocks at rest must account for the relativistic redshift of the clock frequencies, which is proportional to the corresponding gravity (gravitational plus centrifugal) potential difference. For contributions to international timescales, the relativistic redshift correction must be computed with respect to a conventional zero potential value in order to be consistent with the definition of Terrestrial Time. To benefit fully from the uncertainty of the optical clocks, the gravity potential must be determined with an accuracy of about \(0.1\,\hbox {m}^{2}\,\hbox {s}^{-2}\), equivalent to about 0.01 m in height. This contribution focuses on the static part of the gravity field, assuming that temporal variations are accounted for separately by appropriate reductions. Two geodetic approaches are investigated for the derivation of gravity potential values: geometric levelling and the Global Navigation Satellite Systems (GNSS)/geoid approach. Geometric levelling gives potential differences with millimetre uncertainty over shorter distances (several kilometres), but is susceptible to systematic errors at the decimetre level over large distances. The GNSS/geoid approach gives absolute gravity potential values, but with an uncertainty corresponding to about 2 cm in height. For large distances, the GNSS/geoid approach should therefore be better than geometric levelling. This is demonstrated by the results from practical investigations related to three clock sites in Germany and one in France. The estimated uncertainty for the relativistic redshift correction at each site is about \(2 \times 10^{-18}\).

11 January 2017 in Journal of Geodesy
Verified
Journal Article
Open access
PDF file
GLG. Lion
G. Lion
IPI. Panet
I. Panet
PWP. Wolf
P. Wolf
CGC. Guerlin
C. Guerlin
SBS. Bize
S. Bize
PDPacôme Delva
Pacôme Delva
Recent technological advances in optical atomic clocks are opening new perspectives for the direct determination of geopotential differences between any two points at a centimeter-level accuracy in geoid height. However, so far detailed quantitative estimates of the possible improvement in geoid determination when adding such clock measurements to existing data are lacking. We present a first step in that direction with the aim and hope of triggering further work and efforts in this emerging field of chronometric geodesy and geophysics. We specifically focus on evaluating the contribution of this new kind of direct measurements in determining the geopotential at high spatial resolution (\(\approx \)10 km). We studied two test areas, both located in France and corresponding to a middle (Massif Central) and high (Alps) mountainous terrain. These regions are interesting because the gravitational field strength varies greatly from place to place at high spatial resolution due to the complex topography. Our method consists in first generating a synthetic high-resolution geopotential map, then drawing synthetic measurement data (gravimetry and clock data) from it, and finally reconstructing the geopotential map from that data using least squares collocation. The quality of the reconstructed map is then assessed by comparing it to the original one used to generate the data. We show that adding only a few clock data points (less than 1% of the gravimetry data) reduces the bias significantly and improves the standard deviation by a factor 3. The effect of the data coverage and data quality on the results is investigated, and the trade-off between the measurement noise level and the number of data points is discussed.