Eric Davis

Dr. Eric Davis

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Ultrasonics
Verified
Journal Article
Closed access
VCVAMSHI CHILLARA
VAMSHI CHILLARA
EDEric Davis
Eric Davis
CPCristian Pantea
Cristian Pantea
DSDipen N. Sinha
Dipen N. Sinha

26 January 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
JGJohn Greenhall
John Greenhall
CHChristopher Hakoda
Christopher Hakoda
EDEric Davis
Eric Davis
VCVAMSHI CHILLARA
VAMSHI CHILLARA
Cristian PanteaCristian Pantea
Cristian Pantea
Acoustic time-of-flight (ToF) measurements enable noninvasive material characterization, acoustic imaging, and defect detection and are commonly used in industrial process control, biomedical devices, and national security. When characterizing a fluid contained in a cylinder or pipe, ToF measurements are hampered by guided waves, which propagate around the cylindrical shell walls and obscure the waves propagating through the interrogated fluid. We present a technique for overcoming this limitation based on a broadband linear chirp excitation and cross correlation detection. By using broadband excitation, we exploit the dispersion of the guided waves, wherein different frequencies propagate at different velocities, thus distorting the guided wave signal while leaving the bulk wave signal in the fluid unperturbed. We demonstrate the measurement technique experimentally and using numerical simulation. We characterize the technique performance in terms of measurement error, signal-to-noise-ratio, and resolution as a function of the linear chirp center frequency and bandwidth. We discuss the physical phenomena behind the guided bulk wave interactions and how to utilize these phenomena to optimize the measurements in the fluid.

13 August 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YCYu Chen
Yu Chen
KGKai Gao
Kai Gao
EDEric Davis
Eric Davis
DSDipen N. Sinha
Dipen N. Sinha
Cristian PanteaCristian Pantea
Cristian Pantea
LHLianjie Huang
Lianjie Huang
Los Alamos National Laboratory (LANL) has recently developed an ultrasonic side-lobe suppressed Bessel collimated beam transducer for low-frequency imaging through highly attenuating materials. We study the effectiveness of using such a collimated ultrasonic-beam transducer for imaging concrete heterogeneities outside borehole casing for high-resolution borehole imaging and wellbore integrity monitoring. We obtain detailed concrete heterogeneities including a low-velocity zone using ultrasound data acquired with a 3D imaging prototype and our recently developed full-waveform inversion and least-squares reverse-time migration methods. Full-waveform inversion fits synthetic ultrasonic waveforms with recorded waveforms to build a high-resolution velocity model. Least-squares reverse-time migration produces a high-resolution structural image showing material discontinuities. Our results demonstrate that LANL's 3D imaging system with a collimated ultrasonic-beam transducer together with full-waveform inversion and least-squares reverse-time migration imaging has great potential for high-resolution single-well borehole imaging and non-destructive evaluation.

17 September 2016 in Journal of Geophysical Research: Solid Earth
Verified
Journal Article
Open access
PDF file
EDEric Davis
Eric Davis
BSBlake T. Sturtevant
Blake T. Sturtevant
Dipen SinhaDipen Sinha
Dipen Sinha
Cristian PanteaCristian Pantea
Cristian Pantea
Resonant Ultrasound Spectroscopy was used to determine the elastic moduli of Berea sandstone from room temperature to 478 K. Sandstone is a common component of oil reservoirs, and the temperature range was chosen to be representative of typical downhole conditions, down to about 8 km. In agreement with previous works, Berea sandstone was found to be relatively soft with a bulk modulus of approximately 6 GPa as compared to 37.5 GPa for α-quartz at room temperature and pressure. It was found that Berea sandstone undergoes a ~17% softening in bulk modulus between room temperature and 385 K, followed by an abnormal behavior of similar stiffening between 385 K and 478 K.

18 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GSGonzalo Seisdedos
Gonzalo Seisdedos
EVEdgar Viamontes
Edgar Viamontes
ESEduardo Salazar
Eduardo Salazar
MOMariana Ontiveros
Mariana Ontiveros
Cristian PanteaCristian Pantea
Cristian Pantea
BBBen Boesl
Ben Boesl
Polymers are increasingly being used in higher demanding applications due to their ability to tailor the properties of structures while allowing for a weight and cost reduction. Solvents play an important role in the manufacture of polymeric structures since they allow for a reduction in the polymer’s viscosity or assist with the dispersion of fillers into the polymer matrix. However, the incorrect removal of the solvent affects both the physical and chemical properties of polymeric materials. The presence of residual solvent can also negatively affect the curing kinetics and the final quality of polymers. Destructive testing is mainly performed to characterize the properties of these materials. However, this type of testing involves using lab-type equipment that cannot be taken in-field to perform in situ testing and requires a specific sample preparation. Here, a method is presented to non-destructively evaluate the curing process and final viscoelastic properties of polymeric materials using ultrasonics. In this study, changes in longitudinal sound speed were detected during the curing of an aerospace epoxy adhesive as a result of variations in polymer chemistry. To simulate the presence of residual solvent, samples containing different weight percentages of isopropyl alcohol were manufactured and tested using ultrasonics. Thermogravimetric analysis was used to show changes in the decomposition of the adhesive due to the presence of IPA within the polymer structure. Adding 2, 4, and 6 wt.% of IPA decreased the adhesive’s lap shear strength by 40, 58, and 71%, respectively. Ultrasonics were used to show how the solvent influenced the curing process and the final sound speed of the adhesive. Young’s modulus and Poisson’s ratio were determined using both the longitudinal and shear sound speeds of the adhesive. Using ultrasonics has the potential to non-invasively characterize the quality of polymers in both an in-field and manufacturing settings, ensuring their reliability during use in demanding applications.

1 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ASAbhishek Saini
Abhishek Saini
JGJohn Greenhall
John Greenhall
EDEric Davis
Eric Davis
Cristian PanteaCristian Pantea
Cristian Pantea
Bulk wave acoustic time-of-flight (ToF) measurements in pipes and closed containers can be hindered by guided waves with similar arrival times propagating in the container wall, especially when a low excitation frequency is used to mitigate sound attenuation from the material. Convolutional neural networks (CNNs) have emerged as a new paradigm for obtaining accurate ToF in non-destructive evaluation (NDE) and have been demonstrated for such complicated conditions. However, the generalizability of ToF-CNNs has not been investigated. In this work, we analyze the generalizability of the ToF-CNN for broader applications, given limited training data. We first investigate the CNN performance with respect to training dataset size and different training data and test data parameters (container dimensions and material properties). Furthermore, we perform a series of tests to understand the distribution of data parameters that need to be incorporated in training for enhanced model generalizability. This is investigated by training the model on a set of small- and large-container datasets regardless of the test data. We observe that the quantity of data partitioned for training must be of a good representation of the entire sets and sufficient to span through the input space. The result of the network also shows that the learning model with the training data on small containers delivers a sufficiently stable result on different feature interactions compared to the learning model with the training data on large containers. To check the robustness of the model, we tested the trained model to predict the ToF of different sound speed mediums, which shows excellent accuracy. Furthermore, to mimic real experimental scenarios, data are augmented by adding noise. We envision that the proposed approach will extend the applications of CNNs for ToF prediction in a broader range.