This paper concerns continuous nondisturbing estimation of blood pressure using mechanical plethysmography in connection with standard electrocardiography (ECG). The plethysmography is given by a novel magnetoelastic skin curvature sensor (SC-sensor) applied on the neck over the carotid artery. The sensor consists of a magnetoelastic bilayer partly enclosed by a coil. Bending the bilayer causes large changes of magnetic permeability which can be measured by the coil. The SC-sensor signal and the ECG signal are adaptively processed in order to estimate blood pressure according to a specifically established theoretical model. The model uses estimated vessel radius changes and pulse transit time as parameters. The results show cross correlation coefficients in the range 0.8 up to 0.9 between reference and estimated values of systolic blood pressure, diastolic blood pressure, and systolic/diastolic blood pressure change, whereas the estimation error was below 4 +/- 7 mmHg at rest and increased with the stress level. Limitations of the model applicability are given by a hysteretic behavior of both model parameters due to inert changes in artery stiffness. The SC-sensor and the ECG electrodes cause minimal inconvenience to the patient and offer an approach for a continuous nondisturbing monitoring of blood pressure changes, as being relevant for sleep monitoring or biomechanic feedback
1 May 1994 in Journal of Magnetism and Magnetic Materials
Co-Cr substituted magnesium ferrite nanomaterials (Mg1−xCoxCrxFe2−xO4 with x = 0.0−0.5) have been prepared by the polyethylene glycol assisted micro emulsion method. X-ray diffraction analysis confirms the single-phase cubic close-packed lattice formation of synthesized materials. Hysteresis loops are measured up to field of 4 MA/m and high field region of these loops are modeled using the Law of Approach to saturation to calculate the magnetocrystalline anisotropy constant. The saturation magnetization of the samples increases initially from 148 kA/m for x = 0.0 to 299 kA/m (x = 0.3) and then decreases to 187 kA/m (x = 0.5). Curie temperature for this series is found to be in the range of 618-766 K. Room temperature resistivity increases gradually from 7.5 × 108 Ω cm (x = 0.0) to 3.47 × 109 Ω cm (x = 0.5). Additionally, dielectric measurements are carried out at room temperature in a frequency range of 100 Hz to 3 MHz. With improvement in the values of the above-mentioned properties, the synthesized materials could be suitable for potential application in some magnetic and microwave devices.
1 July 1996 in Journal of Magnetism and Magnetic Materials