Eugenijus Kaniusas

Prof. Dr. Eugenijus Kaniusas

Institute of Biomedical Electronics / TU Wien, Vienna, Wien, Austria
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2019 in Frontiers in Neuroscience
Verified
Journal Article
Open access
EKEugenijus Kaniusas
Eugenijus Kaniusas
SKStefan Kampusch
Stefan Kampusch
MTMarc Tittgemeyer
Marc Tittgemeyer
FPFivos Panetsos
Fivos Panetsos
RGRaquel Fernandez Gines
Raquel Fernandez Gines
JSJozsef Constantin Széles
Jozsef Constantin Széles
Electrical stimulation of the auricular vagus nerve (aVNS) is an emerging technology in the field of bioelectronic medicine with applications in therapy. Modulation of the afferent vagus nerve affects a large number of physiological processes and bodily states associated with information transfer between the brain and body. These include disease mitigating effects and sustainable therapeutic applications ranging from chronic pain diseases, neurodegenerative and metabolic ailments to inflammatory and cardiovascular diseases. Given the current evidence from experimental research in animal and clinical studies we discuss basic aVNS mechanisms and their potential clinical effects. Collectively, we provide a focused review on the physiological role of the vagus nerve and formulate a biology-driven rationale for aVNS. For the first time, two international workshops on aVNS have been held in Warsaw and Vienna in 2017 within the framework of EU COST Action "European network for innovative uses of EMFs in biomedical applications (BM1309)." Both workshops focused critically on the driving physiological mechanisms of aVNS, its experimental and clinical studies in animals and humans, in silico aVNS studies, technological advancements, and regulatory barriers. The results of the workshops are covered in two reviews, covering physiological and engineering aspects. The present review summarizes on physiological aspects - a discussion of engineering aspects is provided by our accompanying article (Kaniusas et al., 2019). Both reviews build a reasonable bridge from the rationale of aVNS as a therapeutic tool to current research lines, all of them being highly relevant for the promising aVNS technology to reach the patient.

24 July 2019 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
EKEugenijus Kaniusas
Eugenijus Kaniusas
SKStefan Kampusch
Stefan Kampusch
MTMarc Tittgemeyer
Marc Tittgemeyer
FPFivos Panetsos
Fivos Panetsos
RGRaquel Fernandez Gines
Raquel Fernandez Gines
ASAntonio Sarolic
Antonio Sarolic
Electrical stimulation of the auricular vagus nerve (aVNS) is an emerging electroceutical technology in the field of bioelectronic medicine with applications in therapy. Artificial modulation of the afferent vagus nerve – a powerful entrance to the brain – affects a large number of physiological processes implicating interactions between the brain and body. Engineering aspects of aVNS determine its efficiency in application. The relevant safety and regulatory issues need to be appropriately addressed. In particular, in silico modeling acts as a tool for aVNS optimization. The evolution of personalized electroceuticals using novel architectures of the closed-loop aVNS paradigms with biofeedback can be expected to optimally meet therapy needs. For the first time, two international workshops on aVNS have been held in Warsaw and Vienna in 2017 within the scope of EU COST Action “European network for innovative uses of EMFs in biomedical applications (BM1309).” Both workshops focused critically on the driving physiological mechanisms of aVNS, its experimental and clinical studies in animals and humans, in silico aVNS studies, technological advancements, and regulatory barriers. The results of the workshops are covered in two reviews, covering physiological and engineering aspects. The present review summarizes on engineering aspects – a discussion of physiological aspects is provided by our accompanying article (Kaniusas et al., 2019). Both reviews build a reasonable bridge from the rationale of aVNS as a therapeutic tool to current research lines, all of them being highly relevant for the promising aVNS technology to reach the patient.

1 January 2012
Verified
Book
Closed access
EKEugenijus Kaniusas
Eugenijus Kaniusas

25 March 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
CPCosima Prahm
Cosima Prahm
ASAlexander Schulz
Alexander Schulz
BPBenjamin Paaben
Benjamin Paaben
JSJohannes Schoisswohl
Johannes Schoisswohl
EKEugenijus Kaniusas
Eugenijus Kaniusas
OAOskar C. Aszmann
Oskar C. Aszmann
Research on machine learning approaches for upper limb prosthesis control has shown impressive progress. However, translating these results from the lab to patient’s everyday lives remains a challenge, because advanced control schemes tend to break down under everyday disturbances, such as electrode shifts. Recently, it has been suggested to apply adaptive transfer learning to counteract electrode shifts using as little newly recorded training data as possible. In this paper, we present a novel, simple version of transfer learning and provide the first user study demonstrating the effectiveness of transfer learning to counteract electrode shifts. For this purpose, we introduce the novel Box and Beans test to evaluate prosthesis proficiency and compare user performance with an initial simple pattern recognition system, the system under electrode shifts, and the system after transfer learning. Our results show that transfer learning could significantly alleviate the impact of electrode shifts on user performance in the Box and Beans test. INDEX TERMS Electromyography, Electrode Shifts, Transfer Learning.

5 June 2006 in IEEE Sensors Journal
Verified
Journal Article
Closed access
EKEugenijus Kaniusas
Eugenijus Kaniusas
HPH. Pfutzner
H. Pfutzner
LML. Mehnen
L. Mehnen
JKJ. Kosel
J. Kosel
CTC. Tellez-Blanco
C. Tellez-Blanco
BMB. Marquardt
B. Marquardt
This paper concerns continuous nondisturbing estimation of blood pressure using mechanical plethysmography in connection with standard electrocardiography (ECG). The plethysmography is given by a novel magnetoelastic skin curvature sensor (SC-sensor) applied on the neck over the carotid artery. The sensor consists of a magnetoelastic bilayer partly enclosed by a coil. Bending the bilayer causes large changes of magnetic permeability which can be measured by the coil. The SC-sensor signal and the ECG signal are adaptively processed in order to estimate blood pressure according to a specifically established theoretical model. The model uses estimated vessel radius changes and pulse transit time as parameters. The results show cross correlation coefficients in the range 0.8 up to 0.9 between reference and estimated values of systolic blood pressure, diastolic blood pressure, and systolic/diastolic blood pressure change, whereas the estimation error was below 4 +/- 7 mmHg at rest and increased with the stress level. Limitations of the model applicability are given by a hysteretic behavior of both model parameters due to inert changes in artery stiffness. The SC-sensor and the ECG electrodes cause minimal inconvenience to the patient and offer an approach for a continuous nondisturbing monitoring of blood pressure changes, as being relevant for sleep monitoring or biomechanic feedback

28 July 2020 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
EKEugenijus Kaniusas
Eugenijus Kaniusas
JSJozsef C. Szeles
Jozsef C. Szeles
SKStefan Kampusch
Stefan Kampusch
NANuria Alfageme-Lopez
Nuria Alfageme-Lopez
DYDaniela Yucuma-Conde
Daniela Yucuma-Conde
FPFivos Panetsos
Fivos Panetsos
Background: Covid-19 is an infectious disease caused by an invasion of the alveolar epithelial cells by coronavirus 19. The most severe outcome of the disease is the Acute Respiratory Distress Syndrome (ARDS) combined with hypoxemia and cardiovascular damage. ARDS and co-morbidities are associated with inflammatory cytokine storms, sympathetic hyperactivity, and respiratory dysfunction. Hypothesis: In the present paper, we present and justify a novel potential treatment for Covid19-originated ARDS and associated co-morbidities, based on the non-invasive stimulation of the auricular branch of the vagus nerve. Methods: Auricular vagus nerve stimulation activates the parasympathetic system including anti-inflammatory pathways (the cholinergic anti-inflammatory pathway and the hypothalamic pituitary adrenal axis) while regulating the abnormal sympatho-vagal balance and improving respiratory control. Results: Along the paper (1) we expose the role of the parasympathetic system and the vagus nerve in the control of inflammatory processes (2) we formulate our physiological and methodological hypotheses (3) we provide a large body of clinical and preclinical data that support the favorable effects of auricular vagus nerve stimulation in inflammation, sympatho-vagal balance as well as in respiratory and cardiac ailments, and (4) we list the (few) possible collateral effects of the treatment. Finally, we discuss auricular vagus nerve stimulation protective potential, especially in the elderly and co-morbid population with already reduced parasympathetic response. Conclusions: Auricular vagus nerve stimulation is a safe clinical procedure and it could be either an effective treatment for ARDS originated by Covid-19 and similar viruses or a supplementary treatment to actual ARDS therapeutic approaches.