Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YCYona Choi
Yona Choi
YJYoung jae Jang
Young jae Jang
KKKum Bae Kim
Kum Bae Kim
JBJungbae Bahng
Jungbae Bahng
SCSang Hyoun Choi
Sang Hyoun Choi
Three-dimensional printing technology has the advantage of facilitating the construction of complex three-dimensional shapes. For this reason, it is widely used in medical and radiological fields. However, few materials with high electron density similar to that of bone exist for fabricating a human phantom. In this study, commercially available filament materials were used with an FDM 3D printer to perform delivery quality assurance (DQA) and were evaluated for medical use. For the bone filament material, BaSO4 was synthesized in five ratios of 2%, 4%, 6%, 8%, and 10% with 40% PBAT and 50~58% PLA. The electron density for the 3D printing material fabricated was obtained using kV energy CT and compared with the electron density of human organs and bones. The radiation beam properties of the 3D printed structures were analyzed as films for treatment using a linear accelerator. As a result, by changing the infill density of the material, it was possible to produce a material similar to the density of human organs, and a homogeneous bone material with HU values ranging from 371 ± 9 to 1013 ± 28 was produced. The 3D printing material developed in this study is expected to be usefully applied to the development of a patient-specific phantom to evaluate the accuracy of radiotherapy.

1 September 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
JYJunyoung Yoon
Junyoung Yoon
CPChong Shik Park
Chong Shik Park
JBJungbae Bahng
Jungbae Bahng
KKKyung-Ryul Kim
Kyung-Ryul Kim
SPSeong Hee Park
Seong Hee Park
EKEun-San Kim
Eun-San Kim

23 October 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KKKyo-Tae Kim
Kyo-Tae Kim
YCYona Choi
Yona Choi
GCGyu-Seok Cho
Gyu-Seok Cho
WJWon-Il Jang
Won-Il Jang
KYKwang-Mo Yang
Kwang-Mo Yang
JBJungbae Bahng
Jungbae Bahng
In this study, some confusing points about electron film dosimetry using white polystyrene suggested by international protocols were verified using a clinical linear accelerator (LINAC). According to international protocol recommendations, ionometric measurements and film dosimetry were performed on an SP34 slab phantom at various electron energies. Scaling factor analysis using ionometric measurements yielded a depth scaling factor of 0.923 and a fluence scaling factor of 1.019 at an electron beam energy of <10 MeV (i.e., R50 < 4.0 g/cm2). It was confirmed that the water-equivalent characteristics were similar because they have values similar to white polystyrene (i.e., depth scaling factor of 0.922 and fluence scaling factor of 1.019) presented in international protocols. Furthermore, percentage depth dose (PDD) curve analysis using film dosimetry showed that when the density thickness of the SP34 slab phantom was assumed to be water-equivalent, it was found to be most similar to the PDD curve measured using an ionization chamber in water as a reference medium. Therefore, we proved that the international protocol recommendation that no correction for measured depth dose is required means that no scaling factor correction for the plastic phantom is necessary. This study confirmed two confusing points that could occur while determining beam characteristics using electron film dosimetry, and it is expected to be used as basic data for future research on clinical LINACs.

19 June 2023 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
YCYona Choi
Yona Choi
KCKook Jin Chun
Kook Jin Chun
JBJungbae Bahng
Jungbae Bahng
SCSang Hyoun Choi
Sang Hyoun Choi
GCGyu Seok Cho
Gyu Seok Cho
HCHyun-Tai Chung
Hyun-Tai Chung

14 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SNSeung-Hee Nam
Seung-Hee Nam
CSChangwook Son
Changwook Son
JBJungbae Bahng
Jungbae Bahng
The development of the fast protection system (FPS) was driven by the critical need to safeguard internal components of the accelerator from beam damage and minimize operational downtime. During accelerator operation, various faults can occur, posing a significant risk. The FPS acts as a rapid response system, initiating a shutdown signal to a reliable chopper system to prevent beam damage and ensure the operational availability of the accelerator. To meet the stringent shut off time requirements specific to critical faults, the FPS was designed to respond within 50 µs, while the total FPS time, including acquisition, redundancy, and processing, needed to be less than 20 µs. In order to achieve these goals, a customized FPS was developed for the RAON heavy-ion accelerator, utilizing the Xilinx ZYNQ system-on-chip (SoC). The FPS system comprised seven acquisition modules, one mitigation module with an embedded SoC, and employed optical fiber connections for efficient data transmission. This article provides a comprehensive account of the design, development, and testing of the FPS system. Experimental tests were conducted to validate its performance. These tests included verifying the accuracy of cyclic redundancy checks, acquiring interlock signals in short pulses, and measuring the delay time during abnormal signal occurrences. Of particular significance is the measurement of the total signal processing time for a 1 km optical cable in the RAON system, which was determined to be 9.8 µs. This result successfully met the stringent requirement of 20 µs for the FPS time. The ability of the FPS to operate within the desired time frame demonstrates its effectiveness in protecting the accelerator’s components from beam damage and minimizing downtime. Consequently, the FPS ensures the operational availability of the accelerator while maintaining the safety and integrity of its internal systems. By providing a detailed account of the FPS’s design, development, and testing, this article contributes valuable insights into the capabilities of the FPS in real-world accelerator scenarios. The successful implementation of the RAON-optimized FPS with the Xilinx ZYNQ SoC reaffirms its effectiveness as a fast and reliable protection system, thus enhancing the overall operational performance of the accelerator.

1 February 2020 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
JBJungbae Bahng
Jungbae Bahng
BLByoung-Seob Lee
Byoung-Seob Lee
EKEun-San Kim
Eun-San Kim
SPSeong Hee Park
Seong Hee Park
HPHyang-Kyu Park
Hyang-Kyu Park
Accelerator Based Neutron Sources (ABNS) have been studied for their utility in materials research as well as for boron neutron captured therapy. By making significant efforts to study the (p,n) and (d,n) nuclear reactions, the specifications of the accelerator system have been determined. In this paper, we compare the design results for two types of radio frequency quadrupole (RFQ) accelerators to provide proton and deuteron beams, respectively. Both systems consist of an electron cyclotron resonance (ECR) ion source, a low-energy beam transport system, an RFQ accelerator, a medium-energy beam transport system, a Be target, and a moderator system. In order to achieve a compact accelerator system at a reasonable cost, different requirements must be applied to the design of RFQ accelerators. The proton RFQ has been designed with an operation frequency of 352 MHz, up to 4 MeV acceleration, 10 mA beam intensity, and a continuous-wave (CW) operation mode to achieve 0.84 × 109 n/(s/cm2) of neutron production. However, the deuteron RFQ has been designed with an operation frequency of 200 MHz, up to 2.5 MeV acceleration, 15 mA of beam intensity, and a CW operation mode to achieve 1.02 × 109 n/(s/cm2) of neutron production. In this paper, we describe the merit of the deuteron based neutron source by comparing two types of the RFQ accelerators for proton and deuteron beams including the common system of the ECR ion source and Be target in detail.