This paper proposes a model predictive control (MPC) framework-based distributed demand side energy management method (denoted as DMPC) for users and utilities in a smart grid. The users are equipped with renewable energy resources (RESs), energy storage system (ESSs) and different types of smart loads. With the proposed method, each user finds an optimal operation routine in response to the varying electricity prices according to his/her own preference individually, for example, the power reduction of flexible loads, the start time of shift-able loads, the operation power of schedulable loads, and the charge/discharge routine of the ESSs. Moreover, in the method a penalty term is used to avoid large fluctuation of the user’s operation routines in two consecutive iteration steps. In addition, unlike traditional energy management methods which neglect the forecast errors, the proposed DMPC method can adapt the operation routine to newly updated data. The DMPC is compared with a frequently used method, namely, a day-ahead programming-based method (denoted as DDA). Simulation results demonstrate the efficiency and flexibility of the DMPC over the DDA method.
It has been established that a postsynaptic scaffolding protein, gephyrin, is essential for anchoring two main groups of inhibitory receptors, GABAA receptors (GABAARs) and glycine receptors (GlyRs), to the postsynaptic sites of neurons. The present study was primarily attempted to examine if expression patterns of gephyrin might be different between jaw‐closing (JC) and jaw‐opening (JO) motoneurons. The JC‐ and JO‐motoneurons in the rat trigeminal motor nucleus (Vm) were located in the dorsolateral (Vm.dl) and ventromedial (Vm.vm) divisions, respectively (Mizuno et al.,). Thus, immunoreactivity (IR) for gephyrin was investigated in the Vm: immunofluorescence histochemistry for gephyrin was combined with retrograde tract‐tracing of fluorogold (FG), which was injected into nerves innervating JC‐muscles or nerves innervating JO‐muscles; neuronal cells were counterstained with propidium iodide (PI). The Vm.dl was discriminated from the Vm.vm by the presence of vesicular glutamate transporter 1 (VGLUT1)‐immunopositive axon terminals, which were distributed in the Vm.dl but not in the Vm.vm (Pang et al., J Comp Neurol;512:595–612). Gephyrin‐IR showed a punctate pattern of fluorescence, and motoneuronal profiles were coated with small clusters of gephyrin‐immunopositive puncta throughout the Vm. The distribution density of such clusters was apparently higher in the Vm.dl than in the Vm.vm; this was confirmed quantitatively by a method similar to that described by Lorenzo et al. (Eur J Neurosci;23:3161–3170). On the basis of the present results, possible correlation between the distribution density of gephyrin clusters in the submembrane region of Vm motoneurons and that of axon terminals making inhibitory synapses on Vm motoneurons was discussed. Anat Rec, 2012.
Clustering islands located close to each other and sharing some common characteristics offer diverse and unique opportunities for tourism, trade, and research, and especially take a crucial part in the military. Remote from inland, islands have relatively limited resources, which makes them dependent on imported energy sources such as oil and gas or renewable energy. However, there are few studies about the energy security of clustering islands. To this end, this study proposes a novel energy optimization framework that aims to optimize the use of their different types of energy among clustering islands and improve the stability of the whole energy internet via a multilayer transportation network. The transportation network also enables islands to serve as emergency power sources for each other in some emergency situations. Specifically, we construct an assignment model that considers multimodal transport, multiobjective, and multiple constraints. To address this issue, we develop an unconstrained-individuals guiding constrained multiobjective optimization algorithm, named uiCMOA. Experimental results demonstrate the effectiveness of the transportation network and the efficiency of the proposed algorithm.
With the high proportion of large-scale distributed wind and solar renewable energy penetration, China's energy supply structure and power grid architecture are undergoing profound changes. In order to deeply analyze and understand the operation characteristics of AC / DC hybrid microgrid system in the energy structure, this paper uses the literature method and case analysis method to discuss and analyze the system architecture design, operation control strategy and typical operation conditions of AC / DC hybrid microgrid, and obtains its basic operation rules, so as to lay the foundation for the accurate and rapid control of the following typical operation conditions. The research results of this paper can not only lay a theoretical and technical foundation for the in-depth discussion of AC / DC hybrid microgrid, but also provide useful reference for relevant workers and builders.