Kebin Li

Dr. Kebin Li

Medical Devices Research Center, National Research Council Canada, 75, de Mortagne, Boucherville, QC J4B 6Y4, Canada

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2008 in Analytical Chemistry
Verified
Journal Article
Closed access
Kebin LiKebin Li
Kebin Li
LCLiviu Clime
Liviu Clime
LTLilin Tay
Lilin Tay
BCBo Cui
Bo Cui
MGMatthias Geissler
Matthias Geissler
TVTeodor Veres
Teodor Veres

29 December 2020 in Processes
Verified
Journal Article
Open access
PDF file
Byeong-Ui MoonByeong-Ui Moon
Byeong-Ui Moon
KMKeith James Morton
Keith James Morton
Kebin LiKebin Li
Kebin Li
CMCaroline Miville-Godin
Caroline Miville-Godin
TVTeodor Veses
Teodor Veses
In this paper, we present a simple, versatile method that creates patterns for cell migration studies using thermoplastic elastomer (TPE). The TPE material used here can be robustly, but reversibly, bonded to a variety of plastic substrates, allowing patterning of cultured cells in a microenvironment. We first examine the bonding strength of TPE to glass and polystyrene substrates and com-pare it to thermoset silicone-based PDMS under various conditions and demonstrate that the TPE can be strongly and reversibly bonded on commercially available polystyrene culture plates. In cell migration studies, cell patterns are templated around TPE features cored from a thin TPE film. We show that the significance of fibroblast cell growth with fetal bovine serum (FBS)-cell culture media compared to the cells cultured without FBS, analyzed over two days of cell culture. This simple approach allows us to generate cell patterns without harsh manipulations like scratch assays and to avoid damaging the cells. We also confirm that the TPE material is non-toxic to cell growth and supports a high viability of fibroblasts and breast cancer cells. We anticipate this TPE-based patterning approach can be further utilized for many other cell patterning applications such as in cell-to-cell communication studies.

9 October 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Kebin LiKebin Li
Kebin Li
JHJavier Alejandro Hernández-Castro
Javier Alejandro Hernández-Castro
KMKeith James Morton
Keith James Morton
TVTeodor Veses
Teodor Veses
Freestanding, flexible and open through-hole polymeric micro- and nanostructured membranes were successfully fabricated over large areas (>16 cm2) via solvent removal of sacrificial scaffolds filled with polymer resin by spontaneous capillary flow. Most of the polymeric membranes were obtained through a rapid UV curing processes via cationic or free radical UV polymerisation. Free standing microstructured membranes were fabricated across a range of curable polymer materials, including: EBECRYL3708 (radical UV polymerisation), CUVR1534 (cationic UV polymerisation) UV lacquer, fluorinated perfluoropolyether urethane methacrylate UV resin (MD700), optical adhesive UV resin with high refractive index (NOA84) and medical adhesive UV resin (1161-M). The present method was also extended to make a thermal set polydimethylsiloxane (PDMS) membranes. The pore sizes for the as-fabricated membranes ranged from 100 µm down to 200 nm and membrane thickness could be varied from 100 µm down to 10 µm. Aspect ratios as high as 16.7 were achieved for the 100 µm thick membranes for pore diameters of approximately 6 µm. Wide-area and uniform, open through-hole 30 µm thick membranes with 15 µm pore size were fabricated over 44 × 44 mm2 areas. As an application example, arrays of Au nanodots and Pd nanodots, as small as 130 nm, were deposited on Si substrates using a nanoaperture polymer through-hole membrane as a stencil.

25 April 2026 in Biomedical Microdevices
Verified
Journal Article
Open access
PDF file
Kebin LiKebin Li
Kebin Li
BMByeong-Ui Moon
Byeong-Ui Moon
LCLiviu Clime
Liviu Clime
LLLjuboje Lukic
Ljuboje Lukic
KMKeith Morton
Keith Morton
TVTeodor Veres
Teodor Veres
Microfluidic systems are increasingly utilized in preclinical research, however, developing platforms that are compatible with large-scale manufacturing remains a critical challenge. In this regard, we show that thermoplastic elastomer (TPE)-based microfluidic chips could be a viable alternative to traditional poly(dimethylsiloxane) (PDMS) devices for drug testing applications. Microfluidic concentration gradient generators are essential components in these systems, enabling local spatial and temporal control of biochemical stimuli for applications such as cellular response studies and drug screening. TPEs offer key advantages, especially, optical transparency, flexibility, and compatibility with high-throughput fabrication processes compared to PDMS, thereby enhancing commercialization potential. This study demonstrates the design and fabrication of TPE-based microfluidic devices incorporating concentration gradient generators that allow precise control over solute distributions. Gradient formation was validated through numerical modeling and co-flow experiments using fluorescent dyes. The platform supported the co-culture of human lung fibroblast cells and human colon adenocarcinoma cells (HT-29), which exhibited coordinated responses to gradients of fetal bovine serum (FBS) and sepantronimum bromide (YM-155). Performance benchmarks against PDMS chips demonstrated comparable functionality, underscoring the potential of TPE-based devices for future scalable and cost-effective drug testing and cellular assays.

1 January 2007 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
Kebin LiKebin Li
Kebin Li
BCBo Cui
Bo Cui
LCLiviu Clime
Liviu Clime
TVTeodor Veses
Teodor Veses