Melvin D'Anastasi

Dr. Melvin D'Anastasi

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2022 in Cancers
Verified
Journal Article
Open access
PDF file
JEJohanna Enke
Johanna Enke
JMJan Hendrik Moltz
Jan Hendrik Moltz
MDMelvin D'Anastasi
Melvin D'Anastasi
Wolfgang Gerhard KunzWolfgang Gerhard Kunz
Wolfgang Gerhard Kunz
CSChristian Schmidt
Christian Schmidt
THThomas Huber
Thomas Huber
The spleen is often involved in malignant lymphoma, which manifests on CT as either splenomegaly or focal, hypodense lymphoma lesions. This study aimed to investigate the diagnostic value of radiomics features of the spleen in classifying malignant lymphoma against non-lymphoma as well as the determination of malignant lymphoma subtypes in the case of disease presence—in particular Hodgkin lymphoma (HL), diffuse large B-cell lymphoma (DLBCL), mantle-cell lymphoma (MCL), and follicular lymphoma (FL). Spleen segmentations of 326 patients (139 female, median age 54.1 +/− 18.7 years) were generated and 1317 radiomics features per patient were extracted. For subtype classification, we created four different binary differentiation tasks and addressed them with a Random Forest classifier using 10-fold cross-validation. To detect the most relevant features, permutation importance was analyzed. Classifier results using all features were: malignant lymphoma vs. non-lymphoma AUC = 0.86 (p < 0.01); HL vs. NHL AUC = 0.75 (p < 0.01); DLBCL vs. other NHL AUC = 0.65 (p < 0.01); MCL vs. FL AUC = 0.67 (p < 0.01). Classifying malignant lymphoma vs. non-lymphoma was also possible using only shape features AUC = 0.77 (p < 0.01), with the most important feature being sphericity. Based on only shape features, a significant AUC could be achieved for all tasks, however, best results were achieved combining shape and textural features. This study demonstrates the value of splenic imaging and radiomic analysis in the diagnostic process in malignant lymphoma detection and subtype classification.

20 August 2022 in European Radiology
Verified
Journal Article
Closed access
PDF file
NBNathania Bonanno
Nathania Bonanno
DCDania Cioni
Dania Cioni
DCDamiano Caruso
Damiano Caruso
CCClemens C. Cyran
Clemens C. Cyran
JDJulien Dinkel
Julien Dinkel
MDMelvin D'Anastasi
Melvin D'Anastasi

1 October 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
MDMelvin D'Anastasi
Melvin D'Anastasi
SESimone Ebenberger
Simone Ebenberger
AAAbdulmajeed Alghamdi
Abdulmajeed Alghamdi
AHAndreas Helck
Andreas Helck
AHAnnika Herlemann
Annika Herlemann
RSRobert Stahl
Robert Stahl
To evaluate the technical outcome, clinical success, and safety of low-milliampere CT fluoroscopy (CTF)-guided percutaneous drain (PD) placement in patients with lymphoceles following radical prostatectomy (RP) with pelvic lymph node dissection (LND). This retrospective analysis comprised 65 patients with PD placement in lymphoceles following RP under low-milliampere CTF guidance. Technical and clinical success were evaluated. Complications within a 30-day time interval associated with CTF-guided PD placement were classified according to SIR. Patient radiation exposure was quantified using dose-length products (DLP) of the pre-interventional planning CT scan (DLPpre), of the sum of intra-interventional CT fluoroscopic acquisitions (DLPintra) and of the post-interventional control CT scan (DLPpost). Eighty-nine lymphoceles were detected. Seventy-seven CT-guided interventions were performed, with a total of 92 inserted drains. CTF-guided lymphocele drainage was technically successful in 100% of cases. For all symptomatic patients, improvement in symptoms was reported within 48 h after intervention. Time course of C-reactive protein and Leucocytes within 30 days revealed a statistically significant (p < 0.0001) decrease. Median DLPpre, DLPintra and DLPpost were 431 mGy*cm, 45 mGy*cm and 303 mGy*cm, respectively. Only one minor complication (self-resolving haematoma over the bladder dome; SIR Grade 2) was observed. Low-milliampere CTF-guided drainage is a safe treatment option in patients with lymphoceles following RP with pelvic LND characterized by high technical and good clinical success rates, which provides rapid symptom relief and serves as definite treatment or as a bridging therapy prior to laparoscopic marsupialisation.

13 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
RSRobert Stahl
Robert Stahl
MSMax Seidensticker
Max Seidensticker
GFGiovanna Negrão de Figueiredo
Giovanna Negrão de Figueiredo
VPVera Pedersen
Vera Pedersen
ACAlexander Crispin
Alexander Crispin
Christoph Gregor TrummChristoph Gregor Trumm
Christoph Gregor Trumm
Purpose: To assess the technical (TS) and clinical success (CS) of CT fluoroscopy-guided drainage (CTD) in patients with symptomatic deep pelvic fluid collections following colorectal surgery. Methods: A retrospective analysis (years 2005 to 2020) comprised 43 drain placements in 40 patients undergoing low-dose (10–20 mA tube current) quick-check CTD using a percutaneous transgluteal (n = 39) or transperineal (n = 1) access. TS was defined as sufficient drainage of the fluid collection by ≥50% and the absence of complications according to the Cardiovascular and Interventional Radiological Society of Europe (CIRSE). CS comprised the marked reduction of elevated laboratory inflammation parameters by ≥50% under minimally invasive combination therapy (i.v. broad-spectrum antibiotics, drainage) within 30 days after intervention and no surgical revision related to the intervention required. Results: TS was gained in 93.0%. CS was obtained in 83.3% for C-reactive Protein and in 78.6% for Leukocytes. In five patients (12.5%), a reoperation due to an unfavorable clinical outcome was necessary. Total dose length product (DLP) tended to be lower in the second half of the observation period (median: years 2013 to 2020: 544.0 mGy*cm vs. years 2005 to 2012: 735.5 mGy*cm) and was significantly lower for the CT fluoroscopy part (median: years 2013 to 2020: 47.0 mGy*cm vs. years 2005 to 2012: 85.0 mGy*cm). Conclusions: Given a minor proportion of patients requiring surgical revision due to anastomotic leakage, the CTD of deep pelvic fluid collections is safe and provides an excellent technical and clinical outcome. The reduction of radiation exposition over time can be achieved by both the ongoing development of CT technology and the increased level of interventional radiology (IR) expertise.

6 February 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
RSRobert Stahl
Robert Stahl
MSMax Seidensticker
Max Seidensticker
HAHelmut Arbogast
Helmut Arbogast
DKDavid Kuppinger
David Kuppinger
VGVeronika Greif
Veronika Greif
Christoph Gregor TrummChristoph Gregor Trumm
Christoph Gregor Trumm
Purpose: Evaluation of the effectiveness of CT-guided drainage (CTD) placement in managing symptomatic postoperative fluid collections in liver transplant patients. The assessment included technical success, clinical outcomes, and the occurrence of complications during the peri-interventional period. Methods: Analysis spanned the years 2005 to 2020 and involved 91 drain placement sessions in 50 patients using percutaneous transabdominal or transhepatic access. Criteria for technical success (TS) included (a) achieving adequate drainage of the fluid collection and (b) the absence of peri-interventional complications necessitating minor or prolonged hospitalization. Clinical success (CS) was characterized by (a) a reduction or normalization of inflammatory blood parameters within 30 days after CTD placement and (b) the absence of a need for surgical revision within 60 days after the intervention. Inflammatory markers in terms of C-reactive protein (CRP), leukocyte count and interleukin-6, were evaluated. The dose length product (DLP) for various intervention steps was calculated. Results: The TS rate was 93.4%. CS rates were 64.3% for CRP, 77.8% for leukocytes, and 54.5% for interleukin-6. Median time until successful decrease was 5.0 days for CRP and 3.0 days for leukocytes and interleukin-6. Surgical revision was not necessary in 94.0% of the cases. During the second half of the observation period, there was a trend (p = 0.328) towards a lower DLP for the entire intervention procedure (median: years 2013 to 2020: 623.0 mGy·cm vs. years 2005 to 2012: 811.5 mGy·cm). DLP for the CT fluoroscopy component was significantly (p = 0.001) lower in the later period (median: years 2013 to 2020: 31.0 mGy·cm vs. years 2005 to 2012: 80.5 mGy·cm). Conclusions: The TS rate of CT-guided drainage (CTD) placement was notably high. The CS rate ranged from fair to good. The reduction in radiation exposure over time can be attributed to advancements in CT technology and the growing expertise of interventional radiologists.

30 August 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
RSRobert Stahl
Robert Stahl
MDMelvin D'Anastasi
Melvin D'Anastasi
RFRobert Forbrig
Robert Forbrig
TLThomas Liebig
Thomas Liebig
SKSophie Katzendobler
Sophie Katzendobler
Christoph Gregor TrummChristoph Gregor Trumm
Christoph Gregor Trumm
Purpose: To assess accuracy, the frequency of hemorrhagic complications and computed tomography (CT) radiation dose parameters in pediatric patients undergoing landmark-guided external ventricular drain (EVD) placement in an emergency setting. Methods: Retrospective analysis comprised 36 EVD placements with subsequent CT control scans in 29 patients (aged 0 to 17 years) in our university hospital from 2008 to 2022. The position of the EVD as well as the presence and extension of bleeding were classified according to previously established grading schemes. Dose length product (DLP), volume-weighted CT dose index (CTDIvol) and scan length were extracted from the radiation dose reports and compared to the diagnostic reference values (DRLs) issued by the German Federal Office for Radiation Protection. Results: After the initial EVD placement, optimal positioning of the catheter tip into the ipsilateral frontal horn or third ventricle (Grade I), or a functional positioning in the contralateral lateral ventricle or the non-eloquent cortex (Grade II), was achieved in 28 and 8 cases, respectively. In 32 of 36 procedures, no evidence of hemorrhage was present in the control CT scan. Grade 1 (<1 mL) and Grade 2 (≥1 to 15 mL) bleedings were detected after 3 and 1 placement(s), respectively. For control scans after EVD placements, CTDIvol (median [25%; 75% quartile]) was 39.92 [30.80; 45.55] mGy, DLP yielded 475.50 [375.00; 624.75] mGy*cm and the scan length result was 136 [120; 166] mm. Exceedances of the DRL values were observed in 14.5% for CTDIvol, 12.7% for DLP and 65.6% for the scan length. None of these values was in the range requiring a report to the national authorities. Conclusion: Landmark-based emergency EVD placement in pediatric patients yielded an optimal position in most cases already after the initial insertion. Complications in terms of secondary hemorrhages are rare. CT dose levels associated with the intervention are below the reportable threshold of the national DRLs in Germany.