Julio César C Ramı́rez San Juan

Dr. Julio César C Ramı́rez San Juan

Instituto Nacional de Astrofisica Optica y Electronica, Puebla 72840, Mexico

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
JJJulio César C Ramı́rez San Juan
Julio César C Ramı́rez San Juan
RRRuben Ramos-García
Ruben Ramos-García
IGIleana Guizar-Iturbide
Ileana Guizar-Iturbide
GMGabriel Martínez-Niconoff
Gabriel Martínez-Niconoff
BCBernard Choi
Bernard Choi
Since blood flow is tightly coupled to the health status of biological tissue, several instruments have been developed to monitor blood flow and perfusion dynamics. One such instrument is laser speckle imaging. The goal of this study was to evaluate the use of two velocity distribution assumptions (Lorentzian- and Gaussian-based) to calculate speckle flow index (SFI) values. When the normalized autocorrelation function for the Lorentzian and Gaussian velocity distributions satisfy the same definition of correlation time, then the same velocity range is predicted for low speckle contrast (0<C<0.6) and predict different flow velocity range for high contrast. Our derived equations form the basis for simplified calculations of SFI values.

24 September 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
EFE. Flores-Flores
E. Flores-Flores
STS. A. Torres-Hurtado
S. A. Torres-Hurtado
RPR. Páez
R. Páez
URUlises Ruiz
Ulises Ruiz
GBG. Beltrán-Pérez
G. Beltrán-Pérez
RRRuben Ramos-Garcia
Ruben Ramos-Garcia
In this work we demonstrate optical trapping and manipulation of microparticles suspended in water due to laser-induced convection currents. Convection currents are generated due to laser light absorption in an hydrogenated amorphous silicon (a:Si-H) thin film. The particles are dragged towards the beam's center by the convection currents (Stokes drag force) allowing trapping with powers as low as 0.8 mW. However, for powers >3 mW trapped particles form a ring around the beam due to two competing forces: Stokes drag and thermo-photophoretic forces. Additionally, we show that dynamic beam shaping can be used to trap and manipulate multiple particles by photophotophoresis without the need of lithographically created resistive heaters.

12 April 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
JJJulio César C Ramı́rez San Juan
Julio César C Ramı́rez San Juan
ERE. Rodriguez-Aboytes
E. Rodriguez-Aboytes
AMA. E. Martinez-Canton
A. E. Martinez-Canton
OBOSCAR BALDOVINO-PANTALEON
OSCAR BALDOVINO-PANTALEON
ARArturo Robledo-Martinez
Arturo Robledo-Martinez
RRR. Ramos-Garcia
R. Ramos-Garcia
We present novel results on thermocavitation using a CW medium-power near infrared laser (λ=975 nm) focused into a saturated copper nitrate saline solution. Due to the large absorption coefficient at the laser wavelength, the solution can be heated to its superheat limit (Tsh~270-300°C). Superheated water undergoes explosive phase transition around Tsh producing approximately half-hemispheric bubbles (γ~0.5) in close contact with the substrate. We report the temporal dynamic of the cavitation bubble, which is much shorter than previously reported under similar conditions. It was found that the bubble radius and pressure wave amplitude emitted on bubble collapse decreases exponentially with the power laser. Thermocavitation can be a useful tool for the generation of ultrasonic waves and controlled ablation for use in high-resolution lithography.

30 August 2013 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
JJJulio César C Ramı́rez San Juan
Julio César C Ramı́rez San Juan
EMEmilia Margarita Méndez-Aguilar
Emilia Margarita Méndez-Aguilar
NSN. Salazar-Hermenegildo
N. Salazar-Hermenegildo
AFA. Fuentes-Garcia
A. Fuentes-Garcia
RRR. Ramos-Garcia
R. Ramos-Garcia
BCB. Choi
B. Choi
Laser Speckle Contrast Imaging (LSCI) is an optical technique used to generate blood flow maps with high spatial and temporal resolution. It is well known that in LSCI, the speckle size must exceed the Nyquist criterion to maximize the speckle's pattern contrast. In this work, we study experimentally the effect of speckle-pixel size ratio not only in dynamic speckle contrast, but also on the calculation of the relative flow speed for temporal and spatial analysis. Our data suggest that the temporal LSCI algorithm is more accurate at assessing the relative changes in flow speed than the spatial algorithm.

1 October 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JJJulio César C Ramı́rez San Juan
Julio César C Ramı́rez San Juan
CRCaitlin Regan
Caitlin Regan
BCBeatriz Coyotl-Ocelotl
Beatriz Coyotl-Ocelotl
BCBernard Choi
Bernard Choi
Previously published data demonstrate that the temporal processing algorithm for laser speckle contrast imaging (LSCI) can improve the visibility of deep blood vessels and is less susceptible to static speckle artifacts when compared with the spatial algorithm. To the best of our knowledge, the extent to which the temporal algorithm can accurately predict the speckle contrast associated with flow in deep blood vessels has not been quantified. Here, we employed two phantom systems and imaging setups (epi-illumination and transillumination) to study the contrast predicted by the spatial and temporal algorithms in subsurface capillary tubes as a function of the camera exposure time and the actual flow speed. Our data with both imaging setups suggest that the contrast predicted by the temporal algorithm, and therefore the relative flow speed, is nearly independent of the degree of static optical scattering that contributes to the overall measured speckle pattern. Collectively, these results strongly suggest the potential of temporal LSCI at a single-exposure time to assess accurately the changes in blood flow even in the presence of substantial static optical scattering.

30 January 2014 in Optics Letters
Verified
Journal Article
Open access
PDF file
JJJulio César C Ramı́rez San Juan
Julio César C Ramı́rez San Juan
RRR. Ramos-Garcia
R. Ramos-Garcia
GMG. Martinez-Niconoff
G. Martinez-Niconoff
BCB. Choi
B. Choi
One of the major constraints facing laser speckle imaging for blood-flow measurement is reliable measurement of the correlation time (τC) of the back-scattered light and, hence, the blood’s speed in blood vessels. In this Letter, we present a new model expression for integrated speckle contrast, which accounts not only for temporal integration but spatial integration, too, due to the finite size of the pixel of the CCD camera; as a result, we find that a correction factor should be introduced to the measured speckle contrast to properly determine τC; otherwise, the measured blood’s speed is overestimated. Experimental results support our theoretical model.