Yiteng Liu

Dr. Yiteng Liu

Hong Kong University of Science and Technology, Hong Kong, China
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2022 in Cement and Concrete Composites
Verified
Journal Article
Closed access
ZDZiyi Dai
Ziyi Dai
HGHongda Guo
Hongda Guo
QHQiaoxian Huang
Qiaoxian Huang
SDSen Ding
Sen Ding
YLYiteng Liu
Yiteng Liu
BZBingpu Zhou
Bingpu Zhou

15 December 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
XCXuee CHEN
Xuee CHEN
QSQi Song
Qi Song
BZBeini Zhang
Beini Zhang
YGYibo Gao
Yibo Gao
KLKai Lou
Kai Lou
WWWeijia Wen
Weijia Wen
We designed a silicon-based fast-generated static droplets array (SDA) chip and developed a rapid digital polymerase chain reaction (dPCR) detection platform that is easy to load samples for fluorescence monitoring. By using the direct scraping method for sample loading, a droplet array of 2704 microwells with each volume of about 0.785 nL can be easily realized. It was determined that the sample loading time was less than 10 s with very simple and efficient characteristics. In this platform, a pressurized thermal cycling device was first used to solve the evaporation problem usually encountered for dPCR experiments, which is critical to ensuring the successful amplification of templates at the nanoliter scale. We used a gradient dilution of the hepatitis B virus (HBV) plasmid as the target DNA for a dPCR reaction to test the feasibility of the dPCR chip. Our experimental results demonstrated that the dPCR chip could be used to quantitatively detect DNA molecules. Furthermore, the platform can measure the fluorescence intensity in real-time. To test the accuracy of the digital PCR system, we chose three-channel silicon-based chips to operate real-time fluorescent PCR experiments on this platform.

13 October 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
XCXiaojing Chen
Xiaojing Chen
YLYiteng Liu
Yiteng Liu
XZXuan Zhan
Xuan Zhan
YGYibo Gao
Yibo Gao
ZSZhong yi Sun
Zhong yi Sun
WZWeidong Zheng
Weidong Zheng
With the evolution of the pandemic caused by the Coronavirus disease of 2019 (COVID-19), reverse transcriptase-polymerase chain reactions (RT-PCR) have invariably been a golden standard in clinical diagnosis. Nevertheless, the traditional polymerase chain reaction (PCR) is not feasible for field application due to its drawbacks, such as time-consuming and laboratory-based dependence. To overcome these challenges, a microchip-based ultrafast PCR system called SWM-02 was proposed to make PCR assay in a rapid, portable, and low-cost strategy. This novel platform can perform 6-sample detection per run using multiple fluorescent channels and complete an ultrafast COVID-19 RT-PCR test within 40 min. Here, we evaluated the performance of the microdevice using the gradient-diluted COVID-19 reference samples and commercial PCR kit and determined its limit-of-detection (LoD) as 500 copies/mL, whose variation coefficients for the nucleocapsid (N) gene and open reading frame 1 ab region (ORF1ab) gene are 1.427% and 0.7872%, respectively. The system also revealed an excellent linear correlation between cycle threshold (Ct) values and dilution factors (R2 > 0.99). Additionally, we successfully detected the target RNAs and internal gene in the clinical samples by fast PCR, which shows strong consistency with conventional PCR protocol. Hence, with compact dimension, user-friendly design, and fast processing time, SWM-02 has the capability of offering timely and sensitive on-site molecular diagnosis for prevention and control of pathogen transmission.

Verified
Journal Article
Open access
PDF file
SYSiyu Yang
Siyu Yang
XXXian Xian
Xian Xian
YLYiteng Liu
Yiteng Liu
ZZZiyi Zhang
Ziyi Zhang
QSQi Song
Qi Song
WWWeijia Wen
Weijia Wen
Polydimethylsiloxane (PDMS) has been widely used to make lab-on-a-chip devices, such as reactors and sensors, for biological research. Real-time nucleic acid testing is one of the main applications of PDMS microfluidic chips due to their high biocompatibility and transparency. However, the inherent hydrophobicity and excessive gas permeability of PDMS hinder its applications in many fields. This study developed a silicon-based polydimethylsiloxane-polyethylene-glycol (PDMS-PEG) copolymer microfluidic chip, the PDMS-PEG copolymer silicon chip (PPc-Si chip), for biomolecular diagnosis. By adjusting the modifier formula for PDMS, the hydrophilic switch occurred within 15 s after contact with water, resulting in only a 0.8% reduction in transmittance after modification. In addition, we evaluated the transmittance at a wide range of wavelengths from 200 nm to 1000 nm to provide a reference for its optical property study and application in optical-related devices. The improved hydrophilicity was achieved by introducing a large number of hydroxyl groups, which also resulted in excellent bonding strength of PPc-Si chips. The bonding condition was easy to achieve and time-saving. Real-time PCR tests were successfully conducted with higher efficiency and lower non-specific absorption. This chip has a high potential for a wide range of applications in point-of-care tests (POCT) and rapid disease diagnosis.

21 January 2023 in Molecules
Verified
Journal Article
Open access
PDF file
SYSiyu Yang
Siyu Yang
ZZZiyi Zhang
Ziyi Zhang
XXXian Xian
Xian Xian
QSQi Song
Qi Song
YLYiteng Liu
Yiteng Liu
WWWeijia Wen
Weijia Wen
Real-time polymerase chain reaction (real-time PCR) tests were successfully conducted in an aluminum-based microfluidic chip developed in this work. The reaction chamber was coated with silicone-modified epoxy resin to isolate the reaction system from metal surfaces, preventing the metal ions from interfering with the reaction process. The patterned aluminum substrate was bonded with a hydroxylated glass mask using silicone sealant at room temperature. The effect of thermal expansion was counteracted by the elasticity of cured silicone. With the heating process closely monitored, real-time PCR testing in reaction chambers proceeded smoothly, and the results show similar quantification cycle values to those of traditional test sets. Scanning electron microscope (SEM) and atomic force microscopy (AFM) images showed that the surface of the reaction chamber was smoothly coated, illustrating the promising coating and isolating properties. Energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and inductively coupled plasma-optical emission spectrometer (ICP-OES) showed that no metal ions escaped from the metal to the chip surface. Fourier-transform infrared spectroscopy (FTIR) was used to check the surface chemical state before and after tests, and the unchanged infrared absorption peaks indicated the unreacted, antifouling surface. The limit of detection (LOD) of at least two copies can be obtained in this chip.

2 April 2022 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
BZBeini Zhang
Beini Zhang
YLYiteng Liu
Yiteng Liu
QSQi Song
Qi Song
BLBo Li
Bo Li
XCXuee Chen
Xuee Chen
WWWeijia Wen
Weijia Wen