Zahid Mahmood Khan

Prof. Dr. Zahid Mahmood Khan

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2009 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
AMAmir Haider Malik
Amir Haider Malik
ZKZahid Mahmood Khan
Zahid Mahmood Khan
QMQaisar Mahmood
Qaisar Mahmood
SNSadia Nasreen
Sadia Nasreen
ZBZulfiqar Ahmed Bhatti
Zulfiqar Ahmed Bhatti

1 July 2010 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
SSSajid Hussain Shah
Sajid Hussain Shah
ZKZahid Mahmood Khan
Zahid Mahmood Khan
IRIftikhar Ahmad Raja
Iftikhar Ahmad Raja
QMQaisar Mahmood
Qaisar Mahmood
ZBZulfiqar Ahmad Bhatti
Zulfiqar Ahmad Bhatti
DWDonglei Wu
Donglei Wu

22 May 2020 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
Tariqul IslamTariqul Islam
Tariqul Islam
Changsheng PengChangsheng Peng
Changsheng Peng
Imran AliImran Ali
Imran Ali
Juying LiJuying Li
Juying Li
ZKZahid Mahmood Khan
Zahid Mahmood Khan
Iffat NazIffat Naz
Iffat Naz

22 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
Muhammad AleemMuhammad Aleem
Muhammad Aleem
GHGhulam Hussain
Ghulam Hussain
Muhammad SultanMuhammad Sultan
Muhammad Sultan
Takahiko MiyazakiTakahiko Miyazaki
Takahiko Miyazaki
Muhammad Hamid Hamid MahmoodMuhammad Hamid Hamid Mahmood
Muhammad Hamid Hamid Mahmood
ZKZahid Mahmood Khan
Zahid Mahmood Khan
In this study, experimental apparatus of desiccant dehumidification was developed at lab-scale, using silica gel as a desiccant material. Experimental data were obtained at various ambient air conditions, while focusing the climatic conditions of Multan (Pakistan). A steady-state analysis approach for the desiccant dehumidification process was used, and thereby the slope of desiccant dehumidification line on psychrometric chart (ϕ*) was determined. It has been found that ϕ* = 0.22 in case of silica gel which is lower than the hydrophilic polymeric sorbent, i.e., ϕ* = 0.31. The study proposed two kinds of systems, i.e., (i) standalone desiccant air-conditioning (DAC) and (ii) Maisotsenko-cycle-assisted desiccant air-conditioning (M-DAC) systems. In addition, two kinds of desiccant material (i.e., silica gel and hydrophilic polymeric sorbent) were investigated from the thermodynamic point of view for both system types, using the experimental data and associated results. The study aimed to determine the optimum air-conditioning (AC) system type, as well as adsorbent material for building AC application. In this regard, perspectives of dehumidification capacity, cooling capacity, and thermal coefficient of performance (COP) are taken into consideration. According to the results, hydrophilic polymeric sorbent gave a higher performance, as compared to silica gel. In case of both systems, the performance was improved with the addition of Maisotsenko cycle evaporative cooling unit. The maximum thermal COP was achieved by using a polymer-based M-DAC system, i.e., 0.47 at 70 °C regeneration temperature.

12 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
SNShazia Noor
Shazia Noor
Hadeed AshrafHadeed Ashraf
Hadeed Ashraf
Muhammad SultanMuhammad Sultan
Muhammad Sultan
ZKZahid Mahmood Khan
Zahid Mahmood Khan
This study provides comprehensive details of evaporative cooling options for building air-conditioning (AC) in Multan (Pakistan). Standalone evaporative cooling and standalone vapor compression AC (VCAC) systems are commonly used in Pakistan. Therefore, seven AC system configurations comprising of direct evaporative cooling (DEC), indirect evaporative cooling (IEC), VCAC, and their possible combinations, are explored for the climatic conditions of Multan. The study aims to explore the optimum AC system configuration for the building AC from the viewpoints of cooling capacity, system performance, energy consumption, and CO2 emissions. A simulation model was designed in DesignBuilder and simulated using EnergyPlus in order to optimize the applicability of the proposed systems. The standalone VCAC and hybrid IEC-VCAC & IEC-DEC-VCAC system configurations could achieve the desired human thermal comfort. The standalone DEC resulted in a maximum COP of 4.5, whereas, it was 2.1 in case of the hybrid IEC-DEC-VCAC system. The hybrid IEC-DEC-VCAC system achieved maximum temperature gradient (21 °C) and relatively less CO2 emissions as compared to standalone VCAC. In addition, it provided maximum cooling capacity (184 kW for work input of 100 kW), which is 85% higher than the standalone DEC system. Furthermore, it achieved neutral to slightly cool human thermal comfort i.e., 0 to −1 predicted mean vote and 30% of predicted percentage dissatisfied. Thus, the study concludes the hybrid IEC-DEC-VCAC as an optimum configuration for building AC in Multan.

1 March 2019 in Polish Journal of Environmental Studies
Verified
Journal Article
Closed access
ZKZahid Mahmood Khan
Zahid Mahmood Khan
RKRana Muhammad Kanwar
Rana Muhammad Kanwar
HFHafiz Umar Farid
Hafiz Umar Farid
Muhammad SultanMuhammad Sultan
Muhammad Sultan
MAMuhammad Arsalan
Muhammad Arsalan
MAMian Muhammad Ahson Aslam
Mian Muhammad Ahson Aslam
Wastewater (WW) volume generated from both domestic and industrial sectors has increased due to rapid industrialization and urbanization. WW is increasingly used on farms because it is cheap and easily available all year, causing various environmental and health implications. In order to evaluate Multan WW, this study characterizes 154 WW samples collected from 11 disposal stations. These samples were analysed for 23 parameters related to organic matter, nutrients, inorganic matter, and pathogens to determine pollution extent distribution, agricultural reuse potential, and WW treatment database. A major contamination concern was found regarding biological oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total coliform, and E-Coli. The average values of BOD and COD were found to be 2.7 and 3.8 times higher than the permissible limits respectively. The microbiological parameters such as total coliform and E-Coli were found to be 10.6 and 36 times higher than the permissible limits, respectively. However, heavy metals and nutrients were found within the permissible limit except phosphorus. Here, the correlation study on selected WW parameters indicated the direct or indirect relationship among WW constituents and the impact of different sources of pollution on WW characteristics. The present study also presents a critical review of different treatment options according to contamination strength in disposal stations.