KyungTae Kwon

KyungTae Kwon


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2015 in Journal of Radiological Science and Technology
Verified
Journal Article
Closed access
SSSoon-Yong Son
Soon-Yong Son
KCKwan-Woo Choi
Kwan-Woo Choi
JKJung-Min Kim
Jung-Min Kim
HJHoi-Woun Jeong
Hoi-Woun Jeong
KKKyungTae Kwon
KyungTae Kwon
JMJung-Whan Min
Jung-Whan Min
The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and 1.38 mm-1, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2 .44, and 2.46mm-1, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at 1 mm-1, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

13 October 2022 in Polymers
Verified
Journal Article
Open access
PDF file
MYMyeong Seong Yoon
Myeong Seong Yoon
HJHuimin Jang
Huimin Jang
KKKyungTae Kwon
KyungTae Kwon
Currently, protective clothing used in clinical field is the most representative example of efforts to reduce radiation exposure to radiation workers. However, lead is classified as a substance harmful to the human body that can cause lead poisoning. Therefore, research on the development of lead-free radiation shielding bodies is being conducted. In this study, the shielding body was manufactured by changing the size, layer, and height of the nozzle, using a 90.7% pure tungsten filament, a 3D printer material, and we compared its performance with existing protection tools. Our findings revealed that the shielding rate of the mixed tungsten filament was higher than that of the existing protective tools, confirming its potency to replace lead as the most protective material in clinical field.

30 September 2017 in Journal of Radiological Science and Technology
Verified
Journal Article
Closed access
KKKyungTae Kwon
KyungTae Kwon
JMJung-Whan Min
Jung-Whan Min

31 December 2016 in Journal of Radiological Science and Technology
Verified
Journal Article
Closed access
KKKyungTae Kwon
KyungTae Kwon
JKJung-Soo Kim
Jung-Soo Kim
HSHyun-Sun Sim
Hyun-Sun Sim
JMJung-Whan Min
Jung-Whan Min
SSSoon-Yong Son
Soon-Yong Son
DHDong-Kyoon Han
Dong-Kyoon Han

31 December 2018 in Journal of Radiological Science and Technology
Verified
Journal Article
Closed access
KKKyungTae Kwon
KyungTae Kwon

28 October 2016 in JOURNAL OF THE KOREA CONTENTS ASSOCIATION
Verified
Journal Article
Open access
HSHyun-Sun Sim
Hyun-Sun Sim
KKKyungTae Kwon
KyungTae Kwon