In this paper, a novel chromatic differential confocal matrix (CDCM) sensor is proposed and demonstrated for accurate and fast three-dimensional (3D) profiling without mechanical scanning. In contrast to conventional chromatic confocal microscopy (CCM) methods that require spectral expansion and a peak-intensity-wavelength detection algorithm for axial positioning, our CDCM employs the intensity difference between a pair of spectral confocal images to accurately discriminate surface height. Due to the elimination of spectral expansion required by a conventional CCM, the CDCM has an at least one order of magnitude higher axial sensitivity and surface profiling efficiency than a conventional CCM. In the CDCM, axial scanning is achieved by residual chromatic aberration of an achromatic objective and by constructing a difference intensity signal between two spectral confocal images. Spectral confocal images are acquired in a parallel manner by using a digital micromirror device as an array of illumination pinholes and digitally applying the virtual detection pinhole concept. Quantitative evaluation experiments with the proof-of-principle sensor system indicate that with a 10×NA 0.25 objective, the CDCM can achieve better than 0.1 μm axial accuracy with an axial measurement range of approximately 28 μm, a lateral resolution of 0.87 μm.
The spectral and depth (SAD) imaging method plays an important role in the field of computer vision. However, accurate depth estimation and spectral image capture from a single image without increasing the volume of the imaging sensor is still an unresolved problem. Our research finds that a snapshot narrow band imaging (SNBI) method can discern wavelength-dependent spectral aberration and simultaneously capture spectral-aberration defocused images for quantitative depth estimation. First, a micro 4D imaging (M4DI) sensor is proposed by integrating a mono-chromatic imaging sensor with a miniaturized narrow-band microarrayed spectral filter mosaic. The appearance and volume of the M4DI sensor are the same as the integrated mono-chromatic imaging sensor. A simple remapping algorithm was developed to separate the raw image into four narrow spectral band images. Then, a depth estimation algorithm is developed to generate 3D data with a dense depth map at every exposure of the M4DI sensor. Compared with existing SAD imaging method, the M4DI sensor has the advantages of simple implementation, low computational burden, and low cost. A proof-of-principle M4DI sensor was applied to sense the depth of objects and to track a tiny targets trajectory. The relative error in the three-dimensional positioning is less than 7% for objects within 1.1 to 2.8 m.
Aiming at the problem of limited axial range of differential confocal microscopy (DCM) 3D measurement method, this study proposes a method to expand the range of DCM (Differential confocal axial range expansion method based on double fuzzy, DFDCM). The DFDCM enables range expansion by combining layer scanning with DCM. The problem of effective data fusion in each DCM is solved by using double fuzzy ranging. Then, since only three images are required in each DCM, i.e., pre-focus image, reference plane image, and post-focus image, DFDCM can be well adapted to most DCMs. Quantitative evaluation experiments using the parallel object DCM system show that DFDCM can effectively extend the measurement range of DCM. Under a 10×/0.25 objective, the axial distance between two adjacent reference surfaces is 14 μm. In the experiment of step measurement of 28.91 μm, the measurement error is 0.392 μm and the error rate is 1.34%.
9 January 2024 in IEEE Photonics Technology Letters
In this study, a novel differential confocal microscopy (DCM) measurement method called the axial range expansion method for multi-differential confocal three-dimensional imaging is proposed. The method solves the problem of effective data extraction for DCM implementation of the multi-differential confocal (MDCM) method by analyzing the constraints of differential signals in DCM with respect to two confocal signals with axial offsets in DCM. And the processed DCM data from multiple locations are fused to realize the larger sensing measurement range. Experiments with a parallel object dual-detector system show that it is an effective method. Under the 10x/0.25 objective, the axial layer sweep step is $14~\mu \text{m}$ , the measurement error of the step height of $29.302~\mu \text{m}$ is $0.402~\mu \text{m}$ , and the error rate is 1.37%.