Qing YU

Qing YU

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
QYQing YU
Qing YU
KZKun Zhang
Kun Zhang
CCChangcai Cui
Changcai Cui
RZRuilan Zhou
Ruilan Zhou
FCFang Cheng
Fang Cheng
YZYi Zhang
Yi Zhang
In this paper, a new method for measuring the thickness of transparent specimens using chromatic confocal microscopy (CCM) is presented. The conventional CCM thickness measurement model relies on capturing the focal points on the upper and lower surfaces of a transparent specimen. This model has strict specimen placement tolerance and a limited measurement range. In order to overcome these limitations, a new thickness measurement model was developed by adding an auxiliary reflector below the specimen. The thickness of the specimen can be determined by comparing the wavelengths of light focused on the auxiliary reflector before and after placing the measurement specimen. Theoretical analysis and simulation showed that the proposed method has twice the measurement range of the conventional model. In order to verify the proposed CCM measurement model, a laboratory thickness measurement system was developed by the authors’ team. A commercial laser scanning confocal microscope (Carl Zeiss LSM780) was used as the reference system. A set of quartz glasses was measured using both the proposed system and the reference system. Experimental comparison showed that the proposed method was able to achieve a measurement accuracy of 0.25 μm. In addition, repeated measurements conducted at different heights showed negligible variation. Thus, it can be concluded that the specimen placement tolerance was improved significantly compared with the conventional model.

20 May 2021 in Photonics
Verified
Journal Article
Open access
PDF file
QYQing YU
Qing YU
YZYali Zhang
Yali Zhang
WSWenjian Shang
Wenjian Shang
SDShengchao Dong
Shengchao Dong
CWChong Wang
Chong Wang
FCFang Cheng
Fang Cheng
Chromatic confocal microscopy is a widely used method to measure the thickness of transparent specimens. In conventional configurations, both the illumination and imaging axes are perpendicular to the test specimen. The reflection will be very weak when measuring high-transparency specimens. In order to overcome this limitation, a special chromatic confocal measuring system was developed based on inclined illumination. This design was able to significantly improve the signal-to-noise ratio. Compared with conventional designs, the proposed system was also featured by its biaxial optical scheme, instead of a coaxial one. This biaxial design improved the flexibility of the system and also increased the energy efficiency by avoiding light beam splitting. Based on this design, a prototype was built by the authors’ team. In this paper, the theoretical model of this specially designed chromatic confocal system is analyzed, and the calculating formula for the thickness of transparent specimen is provided accordingly. In order to verify its measurement performance, two experimental methodology and results are presented. The experimental results show that the repeatability is better than 0.54 μm, and the axial measurement accuracy of the system could reach the micron level.

8 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JHJianwei Huang
Jianwei Huang
TLTing Liu
Ting Liu
YZYeyu Zhang
Yeyu Zhang
CZChengsen Zhan
Chengsen Zhan
XXXiaona Xie
Xiaona Xie
DYDingrong Yi
Dingrong Yi
Optical fiber sensors are one preferred solution for temperature sensing, especially for their capability of real-time monitoring and remote detection. However, many of them still suffer from a huge sensing system and complicated signal demodulate process. In order to solve these problems, we propose a smartphone-based optical fiber fluorescence temperature sensor. All the components, including the laser, filter, fiber coupler, batteries, and smartphone, are integrated into a 3D-printed shell, on the side of which there is a fiber flange used for the sensing probe connection. The fluorescence signal of the rhodamine B solution encapsulated in the sensing probe can be captured by the smartphone camera and extracted into the R value and G value by a self-developed smartphone application. The temperature can be quantitatively measured by the calibrated G/R-temperature relation, which can be unified using the same linear relationship in all solid–liquid–gas environments. The performance verifications prove that the sensor can measure temperature in high accuracy, good stability and repeatability, and has a long conservation time for at least 3 months. The proposed sensor not only can measure the temperature for remote and real-time detection needs, but it is also handheld with a small size of 167 mm × 85 mm × 75 mm supporting on-site applications. It is a potential tool in the temperature sensing field.

4 March 2022 in Photonics
Verified
Journal Article
Open access
PDF file
QYQing YU
Qing YU
CWChong Wang
Chong Wang
YZYali Zhang
Yali Zhang
SHShengming Hu
Shengming Hu
TLTing Liu
Ting Liu
LXLin Xi
Lin Xi
As a fast, high-accuracy and non-contact method, chromatic confocal microscopy is widely used in micro dimensional measurement. In this area, thickness measurement for transparent specimen is one of the typical applications. In conventional coaxial illumination mode, both the illumination and imaging axes are perpendicular to the test specimen. At the same time, there are also geometric measurement limitations in conventional mode. When measuring high-transparency specimen, the energy efficiency will be quite low, and the reflection will be very weak. This limitation will significantly affect the signal-to-noise ratio. The inclined illumination mode is a good solution to overcome this bottleneck, but the thickness results may vary at different axial positions of the sample. In this paper, an error correction method for thickness measurement of transparent samples is proposed. In the authors’ work, the error correction model was analyzed and simulated, and the influence caused by the different axial positions of sample could be theoretically eliminated. The experimental results showed that the thickness measurement of the samples was practically usable, and the measurement errors were significantly reduced by less than 2.12%, as compared to the uncorrected system. With this error correction model, the standard deviation had decreased significantly, and the axial measurement accuracy of the system can reach the micron level. Additionally, this model has the same correction effect on the samples with different refractive indexes. Therefore, the system can realize the requirement of measurement at different axial positions.

30 April 2021 in Photonics
Verified
Journal Article
Open access
PDF file
HSHang Su
Hang Su
RYRuifang Ye
Ruifang Ye
Fang ChengFang Cheng
Fang Cheng
CCChangcai Cui
Changcai Cui
QYQing YU
Qing YU
Straightness error compensation is a critical process for high-accuracy topography measurement. In this paper, a straightness measurement system was presented based on the principle of fringe interferometry. This system consisted of a moving optical flat and a stationary prism placed close to each other. With a properly aligned incident light beam, the air wedge between the optical flat and the prism would generate the interferogram, which was captured by a digital camera. When the optical flat was moving with the motion stage, the variation in air wedge thickness due to the imperfect straightness of the guideway would lead to a phase shift of the interferogram. The phase shift could be calculated, and the air wedge thickness could be measured accordingly using the image processing algorithm developed in-house. This air wedge thickness was directly correlated with the straightness of the motion stage. A commercial confocal sensor was employed as the reference system. Experimental results showed that the repeatability of the proposed film interferometer represented by σ was within 25 nm. The measurement deviation between the film interferometer and the reference confocal sensor was within ±0.1 µm. Compared with other interferometric straightness measurement technologies, the presented methodology was featured by a simplified design and good environment robustness. The presented system could potentially be able to measure straightness in both linear and angular values, and the main focus was to analyze its linear value measurement capability.

9 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FCFang Cheng
Fang Cheng
ZDZhou Dongfang
Zhou Dongfang
QYQing YU
Qing YU
TTTegoeh Tjahjowidodo
Tegoeh Tjahjowidodo
To improve the accuracy of the current vision-based linear displacement measurement in a large range, a new type of linear displacement sensing system, namely, image grating, is proposed in this paper. The proposed system included a patterned glass plate attached to the moving object and an ultra-low distortion lens for high-accuracy image matching. A DFT local up-sampling phase correlation method was adopted to obtain the sub-pixel translation of the patterns onto the target plate. Multiple sets of stripe patterns with different designs were located on the glass plate to expand the measurement range, based on the principle of phase correlation. In order to improve the measurement accuracy, the main errors of the image grating system were analyzed, and the nonlinear error compensation was completed based on the dynamic calibration of the pixel equivalent. The measurement results, after the error compensation, showed that the total error of the proposed system was less than 2.5 μm in the range of 60 mm, and the repeatability was within 0.16 μm, as quantified by standard deviation.