Tian Qiang

Prof. Dr. Tian Qiang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
MGMin-Jia Gao
Min-Jia Gao
Tian QiangTian Qiang
Tian Qiang
YMYang-Chuan Ma
Yang-Chuan Ma
Jun-Ge LiangJun-Ge Liang
Jun-Ge Liang
YJYanfeng Jiang
Yanfeng Jiang
Due to the increasing number of diabetic patients, early monitoring of glucose levels is particularly important; therefore, glucose biosensors have attracted enormous attention from researchers. In this paper, we propose a glucose microwave biosensor based on RFID and achieve a non-contact measurement of the concentration of glucose solutions. The Reader is a complementary split-ring resonator (CSRR), and the Tag is comprised of a squared spiral capacitor (SSC). A polydimethylsiloxane microfluidic quantitative cavity with a volume of 1.56 μL is integrated on the Tag to ensure that the glucose solution can be accurately set to the sensitive area and fully contacted with the electromagnetic flux. Because the SSC exhibits different capacitances when it contacts glucose solutions of different concentrations, changing the resonant frequency of the CSRR, we can use the relationship to characterize the biosensing response. Measurement results show that bare CSRR and RFID-based biosensors have achieved sensitivities of 0.31 MHz/mg·dL−1 and 10.27 kHz/mg·dL−1, and detection limits of 13.79 mg/dL and 1.19 mg/dL, respectively, and both realize a response time of less than 1 s. Linear regression analysis of the abovementioned biosensors showed an excellent linear relationship. The proposed design provides a feasible solution for microwave biosensors aiming for the non-contact measurement of glucose concentration.

11 February 2019 in IEEE Access
Verified
Journal Article
Open access
AKAlok Kumar
Alok Kumar
FMFanyi Meng
Fanyi Meng
Cong WangCong Wang
Cong Wang
KAKishor Adhikari
Kishor Adhikari
Tian QiangTian Qiang
Tian Qiang
YWYongle Wu
Yongle Wu
This paper presents highly selective, low-loss and miniaturized balun devices fabricated using Integrated Passive Device (IPD) technique for GSM band (900/1800 MHz) and WiFi band (2400 MHz) in mobile applications. Balun devices were fabricated on a gallium arsenide (GaAs) substrate using IPD fabrication process to reduce the overall size (0.05 λg × 0.036 λg at 900 MHz). Each device is the combination of lattice lumped structure with a low pass filter (LPF) and a high pass filter (HPF) configuration. This structural formation of lumped elements helps to reduce the phase mismatch error in balun devices. For all balun devices, the measured results indicated a minimum amplitude imbalance (< 0.47 dB) and low phase imbalance (180 ± 2.6°). Mathematically calculated, calculated after considering parasitic effects, simulated and measured results exhibited a good correlation. The return loss is below 18 dB and insertion loss is below 0.25 dB for the entire fabricated devices. Balun device with a center frequency of 900 MHz has given the best results amongst all fabricated devices.

13 September 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
ZWZhiji Wang
Zhiji Wang
EKEun Seong Kim
Eun Seong Kim
JLJun-Ge Liang
Jun-Ge Liang
Tian QiangTian Qiang
Tian Qiang
Nam Young KimNam Young Kim
Nam Young Kim
This paper reports on the use of gallium arsenide-based integrated passive device technology for the implementation of a miniaturized bandpass filter that incorporates an intertwined circle-shaped spiral inductor and an integrated center-located capacitor. Air-bridge structures were introduced to the outer inductor and inner capacitor for the purpose of space-saving, thereby yielding a filter with an overall chip area of 1178 μm × 970 μm. Thus, not only is the chip area minimized, but the magnitude of return loss is also improved as a result of selective variation of bridge capacitance. The proposed device possesses a single passband with a central frequency of 1.71 GHz (return loss: 32.1 dB), and a wide fractional bandwidth (FBW) of 66.63% (insertion loss: 0.50 dB). One transmission zero with an amplitude of 43.42 dB was obtained on the right side of the passband at 4.48 GHz. Owing to its miniaturized chip size, wide FBW, good out-band suppression, and ability to yield high-quality signals, the fabricated bandpass filter can be implemented in various L-band applications such as mobile services, satellite navigation, telecommunications, and aircraft surveillance.

28 November 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
YMYang-Chuan Ma
Yang-Chuan Ma
Tian QiangTian Qiang
Tian Qiang
MGMin-Jia Gao
Min-Jia Gao
Jun-Ge LiangJun-Ge Liang
Jun-Ge Liang
YJYanfeng Jiang
Yanfeng Jiang
Here, we propose a glucose biosensor with the advantages of quantification, excellent linearity, temperature-calibration function, and real-time detection based on a resistor and capacitor, in which the resistor works as a temperature sensor and the capacitor works as a biosensor. The resistor has a symmetrical meandering type structure that increases the contact area, leading to variations in resistance and effective temperature monitoring of a glucose solution. The capacitor is designed with an intertwined structure that fully contacts the glucose solution, so that capacitance is sensitively varied, and high sensitivity monitoring can be realized. Moreover, a polydimethylsiloxane microfluidic channel is applied to achieve a fixed shape, a fixed point, and quantitative measurements, which can eliminate influences caused by fluidity, shape, and thickness of the glucose sample. The glucose solution in a temperature range of 25–100 °C is measured with variations of 0.2716 Ω/°C and a linearity response of 0.9993, ensuring that the capacitor sensor can have reference temperature information before detecting the glucose concentration, achieving the purpose of temperature calibration. The proposed capacitor-based biosensor demonstrates sensitivities of 0.413 nF/mg·dL−1, 0.048 nF/mg·dL−1, and 0.011 pF/mg·dL−1; linearity responses of 0.96039, 0.91547, and 0.97835; and response times less than 1 second, respectively, at DC, 1 kHz, and 1 MHz for a glucose solution with a concentration range of 25–1000 mg/dL.

28 July 2025 in Nanomaterials
Verified
Journal Article
Open access
PDF file
WGWeixu Gong
Weixu Gong
ZCZhengyang Cai
Zhengyang Cai
SGShengcheng Geng
Shengcheng Geng
ZGZhi Gan
Zhi Gan
JLJunqiao Li
Junqiao Li
MCMengye Cai
Mengye Cai
Carbon nanotube field-effect transistors (CNTFETs) are becoming a strong competitor for the next generation of high-performance, energy-efficient integrated circuits due to their near-ballistic carrier transport characteristics and excellent suppression of short-channel effects. However, CNT FETs with large diameters and small band gaps exhibit obvious bipolarity, and gate-induced drain leakage (GIDL) contributes significantly to the off-state leakage current. Although the asymmetric gate strategy and feedback gate (FBG) structures proposed so far have shown the potential to suppress CNT FET leakage currents, the devices still lack scalability. Based on the analysis of the conduction mechanism of existing self-aligned gate structures, this study innovatively proposed a design strategy to extend the length of the source–drain epitaxial region (Lext) under a vertically stacked architecture. While maintaining a high drive current, this structure effectively suppresses the quantum tunneling effect on the drain side, thereby reducing the off-state leakage current (Ioff = 10−10 A), and has good scaling characteristics and leakage current suppression characteristics between gate lengths of 200 nm and 25 nm. For the sidewall gate architecture, this work also uses single-walled carbon nanotubes (SWCNTs) as the channel material and uses metal source and drain electrodes with good work function matching to achieve low-resistance ohmic contact. This solution has significant advantages in structural adjustability and contact quality and can significantly reduce the off-state current (Ioff = 10−14 A). At the same time, it can solve the problem of off-state current suppression failure when the gate length of the vertical stacking structure is 10 nm (the total channel length is 30 nm) and has good scalability.

13 May 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
JZJun-Ming Zhao
Jun-Ming Zhao
YWYi-Ke Wang
Yi-Ke Wang
BSBo-Wen Shi
Bo-Wen Shi
YWYan-Xiong Wang
Yan-Xiong Wang
YJYan-Feng Jiang
Yan-Feng Jiang
Tian QiangTian Qiang
Tian Qiang
Cytotoxicity assays are crucial for assessing the efficacy of drugs in killing cancer cells and determining their potential therapeutic value. Measurement of the effect of drug concentration, which is an influence factor on cytotoxicity, is of great importance. This paper proposes a cytotoxicity assay using microwave sensors in an end-point approach based on the detection of the number of live cells for the first time. In contrast to optical methods like fluorescent labeling, this research uses a resonator-type microwave biosensor to evaluate the effects of drug concentrations on cytotoxicity by monitoring electrical parameter changes due to varying cell densities. Initially, the feasibility of treating cells with ultrapure water for cell counting by a microwave biosensor is confirmed. Subsequently, inhibition curves generated by both the CCK-8 method and the new microwave biosensor for various drug concentrations were compared and found to be congruent. This agreement supports the potential of microwave-based methods to quantify cell growth inhibition by drug concentrations.