Because of the social importance of hospitals, characterized by energy-intensive users, large-scale refurbishment projects for these types of buildings are required. With the aim of helping researchers and designers, this paper proposes a multistage methodological approach for the optimization of retrofit designs based on energy, environmental, and economic indicators. Some guidelines are also highlighted thanks to the results obtained from a case study of a private hospital in Naples (Southern Italy, Mediterranean climate) located in a constrained landscape area. The first step consists of the calibration of a simulation energy model defined via in situ investigations, direct surveys and monitoring of energy loads and indoor quality. Then, the model is used to verify the effectiveness of several efficiency measures regarding the building envelope, the active energy systems, and the energy conversion from renewables in order to minimize the energy demand with acceptable economic profitability. This case study demonstrates that electricity demand can be reduced by up to 48% with an investment of around EUR 720,030.00; the payback time without national incentives is 10 years, but it can be halved with appropriate financial support.
The adoption of phase change materials (PCMs) is a promising solution for the improvement of building energy performances and indoor comfort, and the integration of geopolymer concrete (GPC) allows recycling materials and reducing the demand for raw materials in concrete production. Both materials contribute to reducing the carbon dioxide emission in the building lifecycle. In this frame, this paper proposes a complete numerical approach for selecting the optimal wall package made of GPC and PCMs in a Mediterranean climate. The first step of the method consists of a parametric analysis for evaluating the incidence on energy performance and thermal comfort of the main designing variables: insulation thickness, air cavity type and its thickness, and PCMs type. Then, assuming the discomfort hours as a limiting constraint, a multi-objective optimization is applied to a subset of solutions for determining the Pareto front solutions. The advantage of the proposed methodology is the combined evaluations of multiple variables with a simplicity in execution; for this reason, it is useful for other researchers aimed at studying innovative solutions. According to obtained results, the better exposure for the proposed wall package is the north or northeast one. The minimization of the cooling energy demand requires the adoption of two PCMs, on internal and external sides, with melting temperature of 26 °C. The optimization of yearly performance requires the adoption of the maximum insulation level on both sides and a not-ventilated air gap between the modules. The cooling and heating energy need can be reduced, respectively, by around −29% and −57%, compared to a reference configuration with vacuum insulation panels and thermal transmittance of 0.4 W/m2 K.