Silvia Ruggiero

Dr. Silvia Ruggiero

Department of Engineering, University of Sannio
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
Fabrizio AscioneFabrizio Ascione
Fabrizio Ascione
Rosa Francesca De MasiRosa Francesca De Masi
Rosa Francesca De Masi
Margherita MastelloneMargherita Mastellone
Margherita Mastellone
Silvia RuggieroSilvia Ruggiero
Silvia Ruggiero
GVGiuseppe Peter Vanoli
Giuseppe Peter Vanoli
The green wall is an engineered technology for stormwater management and climate change mitigation at the urban level. At the building scale, these energy efficiency measures are suitable for improving indoor comfort conditions and for reducing energy needs. Several guidelines are available about vertical greening systems, but these propose design parameters and performance evaluation criteria, often incomparable. In order to facilitate the implementation of proper technical standards, this paper proposes a critical review of more recent scientific investigations. All parameters for the design optimization are discussed as well as the achievable social and private benefits by taking into consideration the type of study (numerical or experimental), the climate conditions, the analysis period, all technical requirements of the green layer as well as of the back wall. The review underlines that a multi-criteria design approach is needed for green vertical systems. Thus, the paper is concluded with a SWOT analysis, evidencing “strengths”, “weaknesses”, “opportunities” and “threats”. The analysis shows that the highlighted benefits will acquire greater relevance considering the increase in global temperatures and the growing need to redevelop densely built urban centers, while some negative aspects may be filled in the future with a deeper preparation of designers and careful choice of materials. The review paper shows, therefore, drivers and barriers occurring designing and implementing green walls.

6 May 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Margarita Niki AssimakopoulosMargarita Niki Assimakopoulos
Margarita Niki Assimakopoulos
Rosa Francesca De MasiRosa Francesca De Masi
Rosa Francesca De Masi
FRFilippo de Rossi
Filippo de Rossi
Dimitra PapadakiDimitra Papadaki
Dimitra Papadaki
Silvia RuggieroSilvia Ruggiero
Silvia Ruggiero
In the 21st century, sustainable development is high on the international agenda, with the implementation of green walls contributing significantly to achieving environmental and social benefits, mainly in the frame of sustainable improvement of the building sector. The installation of a greening system can provide engineered solutions for stormwater management and climate change mitigation at both the urban and building level. This facilitates improving indoor comfort conditions and reducing energy needs. In order to improve the features of products and to facilitate the implementation of a proper technical standard, this paper proposes a critical bibliographic analysis of more recent scientific works. Moreover, by means of a numerical model of an existing single-family apartment, placed in the Mediterranean climate zone, a building envelope refurbishment with a living wall is carried out. A parametric analysis provides evidence for the application of different plants’ types and insulation materials. The results are analyzed considering the energy needs, the thermo-hygrometric comfort, and the outdoor surface temperature variation of the building envelope, emphasizing that a multi-criteria design approach is needed for green vertical systems. The paper provides data and an approach useful for designers and researchers in the evaluation and optimization of the performance of greening systems.

1 August 2021 in Journal of Cleaner Production
Verified
Journal Article
Closed access
RMRosa Francesca De Masi
Rosa Francesca De Masi
Silvia RuggieroSilvia Ruggiero
Silvia Ruggiero
FTFrancesco Tariello
Francesco Tariello
GVGiuseppe Peter Vanoli
Giuseppe Peter Vanoli

23 July 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Silvia RuggieroSilvia Ruggiero
Silvia Ruggiero
Margarita Niki AssimakopoulosMargarita Niki Assimakopoulos
Margarita Niki Assimakopoulos
Rosa Francesca De MasiRosa Francesca De Masi
Rosa Francesca De Masi
FRFilippo de Rossi
Filippo de Rossi
AFAnastasia Fotopoulou
Anastasia Fotopoulou
AFAnnarita Ferrante
Annarita Ferrante
The achievement of sustainable cities and communities is closely linked to an accurate design of the buildings. In this context, the transparent elements of the building envelope have a crucial role since, on one hand, they are a bottleneck in regards to heat and mass transfers and sound propagation, while, on the other hand, they must allow daylight penetration. Thus, they are responsible for occupants’ thermal and visual comfort and their health. Considering passive solutions for windows, the light shelves can improve natural light penetration, reducing the lights’ electricity demand and controlling windows’ related thermal aspects. The scientific literature is characterized by several studies that analyze this topic, which, however, focus only on the daylight field and sometimes the energy saving for lights. Moreover, they often refer to fixed sky type for the simulations. The aim of the present study is to analyze the application of the light shelves with a multi-disciplinary approach, by means of dynamic simulations, in the EnergyPlus engine, for a whole year. A new methodological approach is presented in order to investigate the technology under different fields of interest: daylight, lighting energy, cooling and heating needs, and thermo-hygrometric comfort. The case study chosen is an existing building, a student dormitory belonging to the University of Athens. It is subject to a deep energy renovation to conform to the “nearly Zero Energy Building” target, in the frame of a European research project called Pro-GET-onE (G.A No. 723747). By means of the calibrated numerical model of this HVAC–building system, ten different configurations of light shelves have been investigated. The best solution is given by the application of an internal horizontal light shelf placed at 50 cm from the top of the window with a depth of 90 or 60 cm. It has been found that despite the reduction in electricity demand for lighting, the variation in heating and cooling needs does not always lead to a benefit.

22 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Margherita MastelloneMargherita Mastellone
Margherita Mastellone
Silvia RuggieroSilvia Ruggiero
Silvia Ruggiero
Dimitra PapadakiDimitra Papadaki
Dimitra Papadaki
Nikolaos BarmparesosNikolaos Barmparesos
Nikolaos Barmparesos
AFAnastasia Fotopoulou
Anastasia Fotopoulou
Margarita Niki AssimakopoulosMargarita Niki Assimakopoulos
Margarita Niki Assimakopoulos
On a European scale, the existing building stock has poor energy performance and particularly vulnerable structures. Indeed, most of the existing buildings were built before the introduction of energy standards and under structural safety criteria different from those currently required. It is therefore necessary the intervention in existing buildings according to an integrated approach that contemplates both the structural safety and the energy efficiency of buildings. This study, consistently with the objectives of the European research project “Proactive synergy of integrated Efficient Technologies on buildings’ Envelopes (Pro-GET-OnE)”, proposes a retrofit intervention for a student dormitory of the National and Kapodistrian University of Athens. The scope of the evaluation is to understand how an integrated intervention, that implies a structural and energy retrofit, as well as a spatial redistribution, leads to an improvement of the Indoor Environmental Quality (IEQ). In detail, the structural retrofit was performed through exoskeleton that leads to the addition of new living spaces and to a remodeling of the building facades. The energy retrofit regarded all three levers of energy efficiency, and thus the building envelope, the microclimatic control systems, and the systems from renewable sources. The integrated intervention, in addition to a reduction of energy demand, has led to advantages in terms of IEQ. Thermal comfort, both during summer and winter, is improved and the hours of suitable CO2 concentration pass from 34% in the pre-retrofit stage up to 100% in the post retrofit stage.

30 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Silvia RuggieroSilvia Ruggiero
Silvia Ruggiero
MIMarco Iannantuono
Marco Iannantuono
AFAnastasia Fotopoulou
Anastasia Fotopoulou
Dimitra PapadakiDimitra Papadaki
Dimitra Papadaki
Margarita Niki AssimakopoulosMargarita Niki Assimakopoulos
Margarita Niki Assimakopoulos
AFAnnarita Ferrante
Annarita Ferrante
In order to achieve the ‘nearly zero-energy’ target and a comfortable indoor environment, an important aspect is related to the correct design of the transparent elements of the building envelope. For improving indoor daylight penetration, architectural solutions such as light shelves are nowadays commercially available. These are defined as horizontal or inclined surfaces, fixed or mobile, placed on the inner and/or the outer side of windows, with surface features such to reflect the sunlight to the interior. Given the fact that these elements can influence different domains (i.e., energy need, daylighting, thermal comfort, etc.), the aim of this paper is to apply a multi-objective optimization method within the design of this kind of technology. The case study is a student house in the University of Athens Campus, subject to a deep energy renovation towards nZEB, under the frame of H2020 European project Pro-GET-onE (G.A No 723747). Starting from the numerical model of the building, developed in EnergyPlus, the multi-objective optimization based on a genetic algorithm is implemented. The variables used are various light shelves configurations by differing materials and geometry, as well as different window types and interior context scenarios. Finally, illuminance studies of the pre- and post-retrofit building are also provided through Revit illuminance rendering.