Thierry Bigault

Dr. Thierry Bigault

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2012 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
CHCarina Höglund
Carina Höglund
JBJens Birch
Jens Birch
KAKen Andersen
Ken Andersen
TBThierry Bigault
Thierry Bigault
JBJean-Claude Buffet
Jean-Claude Buffet
LHLars Hultman
Lars Hultman
Due to the very limited availability of 3He, new kinds of neutron detectors, not based on 3He, are urgently needed. Here, we present a method to produce thin films of 10B4C, with maximized detection efficiency, intended to be part of a new generation of large area neutron detectors. B4C thin films have been deposited onto Al-blade and Si wafer substrates by dc magnetron sputtering from natB4C and 10B4C targets in an Ar discharge, using an industrial deposition system. The films were characterized with scanning electron microscopy, elastic recoil detection analysis, x-ray reflectivity, and neutron radiography. We show that the film-substrate adhesion and film purity are improved by increased substrate temperature and deposition rate. A deposition rate of 3.8 Å/s and substrate temperature of 400 °C result in films with a density close to bulk values and good adhesion to film thickness above 3 μm. Boron-10 contents of almost 80 at. % are obtained in 6.3 m2 of 1 μm thick 10B4C thin films coated on Al-blades. Initial neutron absorption measurements agree with Monte Carlo simulations and show that the layer thickness, number of layers, neutron wavelength, and amount of impurities are determining factors. The study also shows the importance of having uniform layer thicknesses over large areas, which for a full-scale detector could be in total ∼1000 m2 of two-side coated Al-blades with ∼1 μm thick 10B4C films.

1 August 2013 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
KAK. Andersen
K. Andersen
TBThierry Bigault
Thierry Bigault
JBJ. Birch
J. Birch
JBJ.C. Buffet
J.C. Buffet
JCJ. Correa
J. Correa
CVC. Vettier
C. Vettier

6 November 2012 in Neutron News
Verified
Journal Article
Closed access
TBThierry Bigault
Thierry Bigault
JBJ. Birch
J. Birch
JBJ. C. Buffet
J. C. Buffet
JCJ. Correa
J. Correa
RHR. Hall-Wilton
R. Hall-Wilton
PEP. Van Esch
P. Van Esch
(2012). 10B multi-grid proportional gas counters for large area thermal neutron detectors. Neutron News: Vol. 23, No. 4, pp. 20-25.

10 September 2001 in Physical Review B
Verified
Journal Article
Closed access
PDF file
TBThierry Bigault
Thierry Bigault
FBF. Bocquet
F. Bocquet
SLS. Labat
S. Labat
Olivier ThomasOlivier Thomas
Olivier Thomas
HRH. Renevier
H. Renevier
We have investigated the structure of buried interfaces in (111) Au:Ni multilayers. Conventional x-ray diffraction at constant energy as well as anomalous x-ray scattering across the Ni absorption K edge have been used. Whereas the fitting of the spectra at a single energy leads to two different possible interfacial structures, the anomalous diffracted intensity variation unambiguously favors a model with an interfacial concentration gradient at one interface. The multilayer presents an intermixed region extending on six atomic planes around the Ni/Au interface, whereas the Au/Ni interface is chemically abrupt. This structure can explain the unusual stress-strain relation previously reported on this system.

25 July 2005 in Physical Review B
Verified
Journal Article
Closed access
PDF file
LPLuca Peverini
Luca Peverini
EZEric Ziegler
Eric Ziegler
TBThierry Bigault
Thierry Bigault
IKIgor Kozhevnikov
Igor Kozhevnikov
The spatial and temporal evolution of the surface of a tungsten film deposited by magnetron sputtering is investigated in situ and in real time by an x-ray scattering technique. The evolution of roughness is described in terms of its power spectral density and derived from scattering measurements performed using synchrotron x-rays at the energy of 17.5keV. The data are analyzed in the frame of the first-order perturbation theory, which does not require any model of film growth and correlation function. The approach allows extracting quantitatively both the degree of conformity and the evolution of the in-plane characteristic length of the replication as a function of the growing film thickness.

1 December 2016 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
CKChristine Klauser
Christine Klauser
TBThierry Bigault
Thierry Bigault
PBPeter Böni
Peter Böni
PCPierre Courtois
Pierre Courtois
ADAnton Devishvili
Anton Devishvili
TSTorsten Soldner
Torsten Soldner