Ken Holst Andersen

Ken Holst Andersen

Auto-generated profile, based on publicly available information

Ken Holst Andersen

Institut Laue–Langevin, 6 rue Jules Horowitz, BP 156, 38042 Grenoble Cedex 9, France

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2002 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
ISI. Sosnowska
I. Sosnowska
WSW. Schäfer
W. Schäfer
WKWinfried Kockelmann
Winfried Kockelmann
KAK.H. Andersen
K.H. Andersen
ITI.O. Troyanchuk
I.O. Troyanchuk

15 May 2012 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
CHCarina Höglund
Carina Höglund
JBJens Birch
Jens Birch
KAKen Andersen
Ken Andersen
TBThierry Bigault
Thierry Bigault
JBJean-Claude Buffet
Jean-Claude Buffet
LHLars Hultman
Lars Hultman
Due to the very limited availability of 3He, new kinds of neutron detectors, not based on 3He, are urgently needed. Here, we present a method to produce thin films of 10B4C, with maximized detection efficiency, intended to be part of a new generation of large area neutron detectors. B4C thin films have been deposited onto Al-blade and Si wafer substrates by dc magnetron sputtering from natB4C and 10B4C targets in an Ar discharge, using an industrial deposition system. The films were characterized with scanning electron microscopy, elastic recoil detection analysis, x-ray reflectivity, and neutron radiography. We show that the film-substrate adhesion and film purity are improved by increased substrate temperature and deposition rate. A deposition rate of 3.8 Å/s and substrate temperature of 400 °C result in films with a density close to bulk values and good adhesion to film thickness above 3 μm. Boron-10 contents of almost 80 at. % are obtained in 6.3 m2 of 1 μm thick 10B4C thin films coated on Al-blades. Initial neutron absorption measurements agree with Monte Carlo simulations and show that the layer thickness, number of layers, neutron wavelength, and amount of impurities are determining factors. The study also shows the importance of having uniform layer thicknesses over large areas, which for a full-scale detector could be in total ∼1000 m2 of two-side coated Al-blades with ∼1 μm thick 10B4C films.

13 December 2008 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
JSJ. R. Stewart
J. R. Stewart
PDP. P. Deen
P. P. Deen
KAK. H. Andersen
K. H. Andersen
HSH. Schober
H. Schober
JBJ.-F. Barthélémy
J.-F. Barthélémy
BLB. Lindenau
B. Lindenau

1 March 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
KAK.H. Andersen
K.H. Andersen
DAD.N Argyriou
D.N Argyriou
AJAndrew Jackson
Andrew Jackson
JHJ. Houston
J. Houston
PHP.F. Henry
P.F. Henry
ASA. Schreyer
A. Schreyer

16 April 2001 in Physical Review B
Verified
Journal Article
Closed access
PDF file
PRP. G. Radaelli
P. G. Radaelli
RIR. M. Ibberson
R. M. Ibberson
DAD. N. Argyriou
D. N. Argyriou
HCH. Casalta
H. Casalta
KAK. H. Andersen
K. H. Andersen
JMJ. F. Mitchell
J. F. Mitchell
Mesoscopic (500–2000 Å) and microscopic (5–20 Å) phase segregation with temperature and magnetic field was studied in the model manganite Pr0.7Ca0.3MnO3 by high-resolution neutron diffraction and inelastic neutron scattering. Intragranular strain-driven mesoscopic segregation between two insulating phases, one of which is charge ordered (CO), sets in below the CO temperature in zero field. The CO phase orders antiferromagnetically, while the other insulating phase shows spin-glass behavior. After field-induced metallization, the CO phase coexists with a ferromagnetic metallic phase.

10 January 2005 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
MTMark. T. F. Telling
Mark. T. F. Telling
KAKen. H. Andersen
Ken. H. Andersen
The OSIRIS neutron instrument on the ISIS pulsed source now affords the option of high-resolution quasi-elastic and inelastic neutron spectroscopy. In this paper, the performance of OSIRIS is presented, with the spectroscopic characteristics of the instrument being discussed in terms of energy resolution, signal to background ratio and neutron count rate. Recent improvements to the spectrometer are described, in particular the effect of cooling the crystal analysers close to liquid helium temperature to enhance the sensitivity of the instrument. The performance of OSIRIS is also likened to back-scattering, crystal analyser spectrometers at other neutron sources.