View All Publications
1 January 2019 in Advances in Civil Engineering Materials
Verified
Journal Article
Closed access
SSSikandar Sajid
Sikandar Sajid
LCLuc Chouinard
Luc Chouinard
NCNicholas Carino
Nicholas Carino
The resonant frequency test (RFT) of molded concrete specimens is a nondestructive test (NDT) method for indirect strength estimation based on the fundamental mode characteristic resonance frequency. In this article, experimental, numerical, and analytical studies were performed to assess the sensitivity of test results to various factors involved in RFT. These factors included vibration modes of the specimen, sensor attachment techniques, contact time of the hammer impact, location of the sensor on the specimen, length to diameter ratio (L/D), and cross-sectional shape of the specimen. Experimental study included concrete specimen preparation in the lab and real-time RFT measurements for robustness of some of the aforementioned factors. Computation models developed using numerical simulations were verified by laboratory test and analytical results. The finite element method–based code, ABAQUS, was employed for computational modeling. Statistical analyses of the experimental results and parametric studies of the computational modeling were used to quantify the effect of the aforementioned factors on uncertainties of strength estimates using RFT measurements. The contact time of the hammer impact and the L/D of the specimen were found to have considerable effect on test results and hence on the concrete strength estimates.

15 June 2022 in Transportation Research Record: Journal of the Transportation Research Board
Verified
Journal Article
Open access
SSSikandar Sajid
Sikandar Sajid
LCLuc Chouinard
Luc Chouinard
FLFrederic Legeron
Frederic Legeron
TUTodd Ude
Todd Ude
EHEddie He
Eddie He
JAJack Ajrab
Jack Ajrab
Autonomous truck platoon (ATP) deployment on road networks has recently attracted significant interest for its potential economic and environmental benefits. However, the impact of platooning on bridges is a concern because of the differences in their live load characteristics compared with those in the existing bridge design specifications. One of the primary aspects in the safe deployment of ATP is to evaluate the reliability of bridge designed using the existing provisions for live loads from potential configurations of ATP. An analysis procedure is proposed and demonstrated for a simple span steel composite bridge designed according to the existing design provisions. Given that many characteristics of the live load distribution such as the bias factor, coefficient of variation (CoV), and the dynamic amplification factor are presently not known for ATP, a parametric approach is used. The bias factor, dynamic amplification, and CoV are parametrized to calculate the live load distribution and quantify its impact on the reliability index. A two-truck platoon with different headway spacings constituted by different trucks in a single lane scenario is considered. The results indicate that the two single lane bridges designed according to existing design specifications are generally reliable (i.e., achieved the target reliability for which the bridge was initially designed) for the range of ATP live loads investigated when the CoV is less than 0.07, bias close to one and headway distances are above 17 ft. Future studies are suggested to include bridges with multiple spans, other bridge types, and a larger number of trucks in the platoons. The main contribution of this paper is to quantify the reliability indices of selected steel composite bridges designed using the existing specifications but subjected to various configurations of ATP loads and the influence of different components of the live load model attributed to the latter.

31 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Salman SaeedSalman Saeed
Salman Saeed
SSSikandar Sajid
Sikandar Sajid
LCLuc Chouinard
Luc Chouinard
Output-only modal analysis using ambient vibration testing is ubiquitous for the monitoring of structural systems, especially for civil engineering structures such as buildings and bridges. Nonetheless, the instrumented nodes for large-scale structural systems need to cover a significant portion of the spatial volume of the test structure to obtain accurate global modal information. This requires considerable time and resources, which can be challenging in large-scale projects, such as the seismic vulnerability assessment over a large number of facilities. In many instances, a simple center-line (stairwell case) topology is generally used due to time, logistical, and economic constraints. The latter, though a fast technique, cannot provide complete modal information, especially for torsional modes. In this research, corner-line instrumented nodes layouts using only a reference and a roving sensor are proposed, which overcome this issue and can provide maximum modal information similar to that from 3D topologies for medium-rise buildings. Parametric studies are performed to identify the most appropriate locations for sensor placement at each floor of a medium-rise building. The results indicate that corner locations at each floor are optimal. The proposed procedure is validated through field experiments on two medium-rise buildings.

12 January 2023 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Closed access
PDF file
SSSikandar Sajid
Sikandar Sajid
LCLuc Chouinard
Luc Chouinard

15 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Salman SaeedSalman Saeed
Salman Saeed
LCLuc Chouinard
Luc Chouinard
SSSikandar Sajid
Sikandar Sajid
The output-only modal analysis is ubiquitously used for structural health monitoring of civil engineering systems. The measurements for such applications require the use of multiple data acquisition systems (DAS) to avoid complicated meshes of cables in high-rise buildings, avoid traffic constriction on a bridge during measurements, or to avoid having limited channels in a single DAS. Nevertheless, such requirements introduce time synchronization problems which potentially lead to erroneous structural dynamic characterization and hence misleading or inconclusive structural health monitoring results. This research aims at proposing a system-identification-based time synchronization algorithm for output-only modal analysis using multiple DAS. A new procedure based on the compensation of the phase angle shifts is proposed to identify and address the time synchronization issue in ambient vibration data measured through multiple DAS. To increase the robustness of the proposed algorithm to the inherent inconsistencies in these datasets, the kernel density function is applied to rank multiple time-shift estimates that are sometimes detected by the algorithm when inaccuracies exist in the data arising from low signal-to-noise ratio and/or presence of colored noise in the ambient excitations. First, the synchronized ambient vibration dataset of a full-scale bridge is artificially de-synchronized and used to present a proof of concept for the proposed algorithm. Next, the algorithm is applied to ambient vibration data of a 30-story, reinforced concrete building, where the synchronization of the data could not be achieved using two DAS despite best efforts. The application of the proposed time synchronization algorithm is shown to both detect and correct the time synchronization discrepancies in the output-only modal analysis.