Transformers play an essential role in power networks, ensuring that generated power gets to consumers at the safest voltage level. However, they are prone to insulation failure from ageing, which has fatal and economic consequences if left undetected or unattended. Traditional detection methods are based on scheduled maintenance practices that often involve taking samples from in situ transformers and analysing them in laboratories using several techniques. This conventional method exposes the engineer performing the test to hazards, requires specialised training, and does not guarantee reliable results because samples can be contaminated during collection and transportation. This paper reviews the transformer oil types and some traditional ageing detection methods, including breakdown voltage (BDV), spectroscopy, dissolved gas analysis, total acid number, interfacial tension, and corresponding regulating standards. In addition, a review of sensors, technologies to improve the reliability of online ageing detection, and related online transformer ageing systems is covered in this work. A non-destructive online ageing detection method for in situ transformer oil is a better alternative to the traditional offline detection method. Moreover, when combined with the Internet of Things (IoT) and artificial intelligence, a prescriptive maintenance solution emerges, offering more advantages and robustness than offline preventive maintenance approaches.
The arrival of virtual power plants (VPPs) marks important progress in the energy sector, providing optimistic solutions to the increasing need for energy flexibility, resilience, and improved energy systems’ integration. VPPs harness several characteristics to bring together distributed energy resources (DERs), resulting in economic gains and improved power grid reliability. Nevertheless, VPPs encounter major challenges when it comes to engaging in energy markets, mainly because there is no all-encompassing policy and regulatory framework specifically designed to accommodate their unique characteristics. This underscores the necessity for research endeavours to develop more advanced methods and structures for the long-term viability of VPPs. To address this concern, the study advocates for the implementation of a multi-aspect framework (MAF) as a systematic approach to thoroughly examine each aspect of virtual power plants (VPPs). A STEEP (social, technological, environmental, economic, and political) analytical tool is utilized to evaluate the challenges, opportunities, and benefits of a VPP in the existing energy markets. The proposed approach highlights important factors and actions that need to be taken to tackle the challenges related to VPP’ entry into energy markets. This study suggests that further support is required to promote the fast and widespread adoption of long-term VPP implementations. For this reason, a more favourable policy and regulatory framework based on social, technological, economic, environmental, and policy considerations is necessary to realize the genuine contributions of VPPs.
Silicone rubber insulators are replacing the conventional ceramic and porcelain insulators rapidly in power transmission and distribution industry. Very limited field knowledge is available about the performance of silicone rubber insulators in polluted and contaminated environments and therefore need further investigation. A comprehensive analysis of silicone rubber sheets (intended for coating outdoor insulators) was carried out in this paper based on experimental results. The main performance parameters analyzed were arc inception voltage and flashover voltage. Dependence of these parameters on equivalent salt deposit density (ESDD), non-soluble salt deposit density (NSDD), relative humidity, ambient temperature, fog rate, dry band formation, dry band location and number of dry bands were investigated extensively. Insulator orientation and its effect on performance were also studied. The authors believe that this paper will provide a comprehensive knowledge about the flashover characteristics of silicone rubber insulators under humid, contaminated and dry band conditions. These results could be used in the selection and design of silicone rubber insulators for polluted environments.
There is a vital need to understand the flashover process of polymeric insulators for safe and reliable power system operation. This paper provides a rigorous investigation of forecasting the flashover parameters of High Temperature Vulcanized (HTV) silicone rubber based on environmental and polluted conditions using machine learning. The modified solid layer method based on the IEC 60507 standard was utilised to prepare samples in the laboratory. The effect of various factors including Equivalent Salt Deposit Density (ESDD), Non-soluble Salt Deposit Density (NSDD), relative humidity and ambient temperature, were investigated on arc inception voltage, flashover voltage and surface resistance. The experimental results were utilised to engineer a machine learning based intelligent system for predicting the aforementioned flashover parameters. A number of machine learning algorithms such as Artificial Neural Network (ANN), Polynomial Support Vector Machine (PSVM), Gaussian SVM (GSVM), Decision Tree (DT) and Least-Squares Boosting Ensemble (LSBE) were explored in forecasting of the flashover parameters. The prediction accuracy of the model was validated with a number of error cost functions, such as Root Mean Squared Error (RMSE), Normalized RMSE (NRMSE), Mean Absolute Percentage Error (MAPE) and R. For improved prediction accuracy, bootstrapping was used to increase the sample space. The proposed PSVM technique demonstrated the best performance accuracy compared to other machine learning models. The presented machine learning model provides promising results and demonstrates highly accurate prediction of the arc inception voltage, flashover voltage and surface resistance of silicone rubber insulators in various contaminated and humid conditions.
Dry band formation on the surface of outdoor insulators is one of the main reasons leading to flashover and power outages. In this paper, a dynamic arc model is proposed for single and multiple dry bands configuration to predict the critical flashover voltage for silicone rubber outdoor insulators. An arc is modelled as a time dependent impedance consisting of a Resistor Inductor Capacitor (RLC) circuit. The effect of dry band location and existence of multiple dry bands on critical flashover voltage is investigated. To validate the proposed model, experiments were conducted in a climate chamber under controlled environmental conditions on rectangular silicone rubber sheets polluted using improved solid layer method based on IEC 60,507. Tests were conducted at different dry band configurations and pollution severity levels. A good correlation was found between experimental results and simulation results. This model can provide a good foundation for the development of mathematical models for station post insulators having multiple dry and clean bands and can be used in the design and selection of outdoor insulators for polluted conditions.
In this work, the extent of natural cleansing effect of rainfall, wind and fog or a combination of these on an insulator string were investigated. Results showed that pollution losses progress with time with a considerable fraction of losses occurring within 15 minutes of testing. While wind alone played little or no role in surface cleansing, it increases the extent of cleansing by rainfall. The topsides of insulators were found to be more affected by natural cleansing compared to the underside. Equivalent Salt Deposit Density (ESDD) and Non-Soluble Deposit Density (NSDD) measurements were carried out. ESDD was found to be higher in the lower disc irrespective of the weather condition the insulator string has been subjected to. NSDD measurements established no pattern on how natural cleansing was impacted by disc position on a string, demonstrating the random nature of pollution-cleansing cycle of outdoor insulators. Insulator performance was assessed by high voltage AC tests and monitoring of partial discharge events using Radio Frequency antennas and a High Frequency Current Transformer (HFCT). Measured output by the HFCT showed that leakage current decreases uniformly with time, and the speed at which this occurs is an indication of the intensity of natural cleansing activity.