The blade pitch system is a critical subsystem of variable-speed variable-pitch wind turbines that is characterized by a high failure rate. This paper addresses the fault detection and isolation (FDI) of a blade pitch system with hydraulic actuators. Focus is placed on incipient multiplicative faults, namely hydraulic oil contamination with water and air, bearing damage resulting in increased friction, and drop of the supply pressure of the hydraulic pump. An active model-based FDI approach is considered, where changes in the operating conditions (i.e., mean wind speed and turbulence intensity) are accounted through the identification of a linear parameter-varying model for the pitch actuators. Frequency-domain estimators are used to identify continuous-time models in a user-defined frequency band, which facilitates the design of the FDI algorithm. Besides, robustness with respect to noise in measurements and stochastic nonlinear distortions is ensured by estimating confidence bounds on the parameters used for FDI. The approach is thoroughly validated on a wind turbine simulator based on the FAST software that includes a detailed physical model of the hydraulic pitch system. This paper presents the design methodology and validation results for the proposed FDI approach. We show that an appropriate design of the excitation signal used for active fault detection allows an early fault diagnosis (except for oil contamination with water) while ensuring a short experiment duration and an acceptable impact on the wind turbine operation.
Corrosion is the leading cause of failure for Offshore Wind Turbine (OWT) structures and it is characterized by a low probability of detection. With focus on uniform corrosion, we propose a corrosion detection and prognosis system coupled with a Decision Support Tool (DST) and a Graphical User Interface (GUI). By considering wall thickness measurements at different critical points along the wind turbine tower, the proposed corrosion detection and prognosis system—based on Kalman filtering, empirical corrosion models and reliability theory—estimates the Remaining Useful Life of the structure with regard to uniform corrosion. The DST provides a systematic approach for evaluating the results of the prognosis module together with economical information, to assess the different possible actions and their optimal timing. Focus is placed on the optimization of the decommissioning time of OWTs. The case of decommissioning is relevant as corrosion—especially in the splash zone of the tower—makes maintenance difficult and very costly, and corrosion inevitably leads to the end of life of the OWT structure. The proposed algorithms are illustrated with examples. The custom GUI facilitates the interpretation of results of the prognosis module and the economical optimization, and the interaction with the user for setting the different parameters and costs involved.