Antonio Mutti

Prof. Antonio Mutti

La Medicina del Lavoro, Parma, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2005 in Respiratory Research
Verified
Journal Article
Open access
PDF file
DPDiana Poli
Diana Poli
PCPaolo Carbognani
Paolo Carbognani
Massimo CorradiMassimo Corradi
Massimo Corradi
Matteo GoldoniMatteo Goldoni
Matteo Goldoni
OAOlga Acampa
Olga Acampa
AMAntonio Mutti
Antonio Mutti
Background: Non-invasive diagnostic strategies aimed at identifying biomarkers of lung cancer are of great interest for early cancer detection. The aim of this study was to set up a new method for identifying and quantifying volatile organic compounds (VOCs) in exhaled air of patients with non-small cells lung cancer (NSCLC), by comparing the levels with those obtained from healthy smokers and non-smokers, and patients with chronic obstructive pulmonary disease. The VOC collection and analyses were repeated three weeks after the NSCLC patients underwent lung surgery. Methods: The subjects' breath was collected in a Teflon® bulb that traps the last portion of single slow vital capacity. The 13 VOCs selected for this study were concentrated using a solid phase microextraction technique and subsequently analysed by means of gas cromatography/mass spectrometry. Results: The levels of the selected VOCs ranged from 10-12 M for styrene to 10-9 M for isoprene. None of VOCs alone discriminated the study groups, and so it was not possible to identify one single chemical compound as a specific lung cancer biomarker. However, multinomial logistic regression analysis showed that VOC profile can correctly classify about 80 % of cases. Only isoprene and decane levels significantly decreased after surgery. Conclusion: As the combination of the 13 VOCs allowed the correct classification of the cases into groups, together with conventional diagnostic approaches, VOC analysis could be used as a complementary test for the early diagnosis of lung cancer. Its possible use in the follow-up of operated patients cannot be recommended on the basis of the results of our short-term nested study.

30 June 2006 in Respiratory Research
Verified
Journal Article
Open access
Mario OlivieriMario Olivieri
Mario Olivieri
GTGiorgio Talamini
Giorgio Talamini
Massimo CorradiMassimo Corradi
Massimo Corradi
Luigi PerbelliniLuigi Perbellini
Luigi Perbellini
AMAntonio Mutti
Antonio Mutti
Mario MalerbaMario Malerba
Mario Malerba
Background: Despite the widespread use of fractional exhaled nitric oxide (FENO) as a biomarker of airways inflammation, there are no published papers describing normal FENO values in a large group of healthy adults. Objective: The aim of this study was to establish adult FENO reference values according to the international guidelines. Methods: FENO was measured in 204 healthy, non-smoking adults with normal spirometry values using the on-line single-breath technique, and the results were analysed chemiluminescently. Results: The main result of the study was the significant difference in FENO values between men and women, thus indicating that gender-based reference FENO values are necessary. The FENO levels obtained at expiratory flows of 50 ml/s ranged from 2.6 to 28.8 ppb in men, and from 1.6 to 21.5 ppb in women. Conclusion: We propose reference FENO values for healthy adult men and women that could be used for clinical and research purposes.

1 May 2006 in Chest
Verified
Journal Article
Closed access
AMAntonio Mutti
Antonio Mutti
Massimo CorradiMassimo Corradi
Massimo Corradi
Matteo GoldoniMatteo Goldoni
Matteo Goldoni
MVMaria Vittoria Vettori
Maria Vittoria Vettori
ABAlfred Bernard
Alfred Bernard
PAPietro Apostoli
Pietro Apostoli

1 December 2004 in European Respiratory Journal
Verified
Journal Article
Closed access
PDF file
Massimo CorradiMassimo Corradi
Massimo Corradi
PPP. Pignatti
P. Pignatti
PMP. Manini
P. Manini
RAR. Andreoli
R. Andreoli
Matteo GoldoniMatteo Goldoni
Matteo Goldoni
AMAntonio Mutti
Antonio Mutti
The aim of the present study was to compare aldehyde levels resulting from lipid peroxidation in exhaled breath condensate (EBC) and induced sputum (IS) supernatant of subjects with asthma and chronic obstructive pulmonary disease (COPD).Aldehydes (malondialdehyde (MDA), acrolein,n-hexanal (C6),n-heptanal (C7),n-nonanal (C9), 4-hydroxynonenal (HNE) and 4-hydroxyhexenal (HHE)) in both biological fluids were measured by liquid chromatography-tandem mass spectrometry.MDA concentrations in sputum were 132.5 nM (82.5–268.8) and 23.7 nM (9–53.7) in EBC. Similarly, C6, C7 and C9 concentrations in IS were 1.5–4.7-fold higher than in EBC. Acrolein levels were 131.1 nM (55.6–264.6) in IS and 45.3 nM (14.4–127.1) in EBC. The concentrations of HNE and HHE in IS were not significantly different from the levels in EBC. Aldehyde levels in EBC did not show any correlation with aldehyde levels in IS or with differential sputum cellular count. In COPD, MDA in EBC, but not its IS counterpart, was negatively correlated with the severity of disease.In conclusion, the data presented here show that aldehydes can be detected in both exhaled breath condensate and supernatant of induced sputum, but that their relative concentrations are different and not correlated with each other. Therefore, with regard to lipid peroxidation products, exhaled breath condensate and induced sputum must be considered as independent techniques.

1 April 2006 in Environmental Health Perspectives
Verified
Journal Article
Open access
ACAndrea Caglieri
Andrea Caglieri
Matteo GoldoniMatteo Goldoni
Matteo Goldoni
OAOlga Acampa
Olga Acampa
RARoberta Andreoli
Roberta Andreoli
MVMaria Vittoria Vettori
Maria Vittoria Vettori
AMAntonio Mutti
Antonio Mutti
Chromium is corrosive, cytotoxic, and carcinogenic for humans and can induce acute and chronic lung tissue toxicity. The aim of this study was to investigate Cr levels in exhaled breath condensate (EBC) of workers exposed to Cr(VI) and to assess their ...

9 December 2014 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
MSMonia Savi
Monia Savi
Rossi StefanoRossi Stefano
Rossi Stefano
LBLeonardo Bocchi
Leonardo Bocchi
LGLaura Gennaccaro
Laura Gennaccaro
FCFrancesca Cacciani
Francesca Cacciani
MZMassimiliano Zaniboni
Massimiliano Zaniboni
In light of recent developments in nanotechnologies, interest is growing to better comprehend the interaction of nanoparticles with body tissues, in particular within the cardiovascular system. Attention has recently focused on the link between environmental pollution and cardiovascular diseases. Nanoparticles <50 nm in size are known to pass the alveolar–pulmonary barrier, enter into bloodstream and induce inflammation, but the direct pathogenic mechanisms still need to be evaluated. We thus focused our attention on titanium dioxide (TiO2) nanoparticles, the most diffuse nanomaterial in polluted environments and one generally considered inert for the human body. We conducted functional studies on isolated adult rat cardiomyocytes exposed acutely in vitro to TiO2 and on healthy rats administered a single dose of 2 mg/Kg TiO2 NPs via the trachea. Transmission electron microscopy was used to verify the actual presence of TiO2 nanoparticles within cardiac tissue, toxicological assays were used to assess lipid peroxidation and DNA tissue damage, and an in silico method was used to model the effect on action potential. Ventricular myocytes exposed in vitro to TiO2 had significantly reduced action potential duration, impairment of sarcomere shortening and decreased stability of resting membrane potential. In vivo, a single intra-tracheal administration of saline solution containing TiO2 nanoparticles increased cardiac conduction velocity and tissue excitability, resulting in an enhanced propensity for inducible arrhythmias. Computational modeling of ventricular action potential indicated that a membrane leakage could account for the nanoparticle-induced effects measured on real cardiomyocytes. Acute exposure to TiO2 nanoparticles acutely alters cardiac excitability and increases the likelihood of arrhythmic events.