1 January 2024 in Thermal Science
Verified
Journal Article
Open access
PDF file
BABiljana Antunović
Biljana Antunović
AJAleksandar Jankovic
Aleksandar Jankovic
Darija GajićDarija Gajić
Darija Gajić
NANevenka Antovic
Nevenka Antovic
JRJelena Rasovic
Jelena Rasovic
MPMilan Popovic
Milan Popovic
The first experimental results of the indoor air quality in two kindergartens located in the Republic of Srpska are presented in this paper. Kindergarten representatives for the year of construction (old and new), building materials, and energy efficiency have been chosen. Indoor air quality measurements (air temperature, relative humidity, ventilation rate, CO2, and radon concentration) were performed during the winter of 2015/2016. Measured indoor air quality parameters are discussed and compared to the international standards BAS EN 16798-1, ASHRAE 62.1, and ISO 7730. The average measured radon concentrations for both buildings have not exceeded the level of 200 Bq/m3, but for reliable results, long-term measurement needs to be performed. The CO2 concentration in the old kindergarten fulfills the BAS EN 16798-1 requirement for Category I during 62.43% of total occupancy time, while for the new kindergarten, it is only 5.79% of full occupancy time. Results of CO2 concentration confirm that good sealing of the envelope of new buildings and user behavior (number of users and natural ventilation) does affect air quality. Furthermore, a high correlation between CO2 concentration and relative humidity in both buildings and a more considerable correlation for the new building have been observed.

12 June 2024
Verified
Conference Paper
Open access
PDF file
SPSlobodan Peulić
Slobodan Peulić
Darija GajićDarija Gajić
Darija Gajić
JKJelena Kljakić
Jelena Kljakić
BABiljana Antunović
Biljana Antunović
Prior to building retrofitting, thermal performance assessment of the building is essential. An adequate assessment can provide useful insights to heat-losses and envelope anomalies i.e. thermal bridges, mold, air infiltration etc. The most important physical quantity that needs to be defined is the thermal transmittance (U-value) which is the key factor in determining the transmission heat loss coefficient HT, as well as in determining the building's energy efficiency. In the absence of documentation, experimental methods are the only solution to identifying such parameter. This paper makes overview of experimental methods; and presents an example of non-destructive method by using Quantitative Infra-Red Thermography (QIRT) in service of calculating U-value of the opaque façade wall element.

30 December 2021 in AГГ+
Verified
Journal Article
Open access
PDF file
TĐTanja Đukanović
Tanja Đukanović
STSanja Tucikešić
Sanja Tucikešić
BABiljana Antunović
Biljana Antunović
This paper analyses how broadcast and precise ephemerides in alignment, using the least-squares method, affect the accuracy of coordinates of the newly included permanent stations. It has been shown that in practice, when аdjusting networks whose span between points exceeds 50 km, the adjustment procedure should be carried out using the adopted precise ephemerides for a specific observation period. Precise ephemerides are recommended for 30 to 50 km baseline lengths, while adjustments with broadcast ephemerides achieves satisfactory accuracy for shorter lengths. For baseline lengths of 30 to 50 km, the use of precise ephemerides is recommended, and for shorter lengths, adjustment with broadcast ephemerides achieves satisfactory accuracy. This paper analyses statistics and presents standard deviations of horizontal and vertical positions, when broadcast and precise ephemerides are applied.

1 December 2021
Verified
Conference Paper
Open access
PDF file
JKJelena Kljakic
Jelena Kljakic
BABiljana Antunović
Biljana Antunović
Radon is by far the largest contributor to population exposure because the dose received from radon and its progeny exceeds all other radiation sources. After smoking, it is the second most frequent cause of the lung cancer, therefore it is classified as Group 1 carcinogenic to humans. The soil under a building is the major source of indoor radon. An important contribution to indoor radon concentration comes from building materials whose composition includes volcano rocks as well as household water. The aim of this paper is to present a brief overview of indoor radon sources and prescribed permitted concentration levels in Bosnia and Herzegovina and the world. Finally, the hazardous effects on human health have been discussed.

1 January 2025
Verified
Book Chapter
Open access
Darija GajićDarija Gajić
Darija Gajić
LPLjubiša Preradović
Ljubiša Preradović
SPSlobodan Peulić
Slobodan Peulić
BABiljana Antunović
Biljana Antunović
MPMilan Pupčević
Milan Pupčević
SCSasa Cvoro
Sasa Cvoro

12 December 2019 in AГГ+
Verified
Journal Article
Open access
PDF file
MVMiroslav Vujasinović
Miroslav Vujasinović
JNJelena Nedić
Jelena Nedić
BABiljana Antunović
Biljana Antunović
MRMiodrag Regodić
Miodrag Regodić
With the advancement of technology in the last ten years and the cheaper development of microchips, new technologies are available for everyone. In addition to high-performance computers, relatively low-cost drones have been developed. This paper presents the possibility of using unmanned aerial vehicles in geodesy as well as flight planning, flight execution, processing of collected data, describes the basic components of the quadcopter, data collection procedure, processing methods as well as accuracy of the obtained results.