Danny Bluestein

Prof. Danny Bluestein

Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2007 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
YAYared Alemu
Yared Alemu
Danny BluesteinDanny Bluestein
Danny Bluestein

1 January 2008 in Journal of Biomechanics
Verified
Journal Article
Closed access
Danny BluesteinDanny Bluestein
Danny Bluestein
YAYared Alemu
Yared Alemu
IAIdit Avrahami
Idit Avrahami
MGMorteza Gharib
Morteza Gharib
KDKris Dumont
Kris Dumont
SEShmuel Einav
Shmuel Einav

22 January 2007 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
KDKris Dumont
Kris Dumont
JVJan Vierendeels
Jan Vierendeels
RKRado Kaminsky
Rado Kaminsky
GNGuido van Nooten
Guido van Nooten
PVPascal Verdonck
Pascal Verdonck
Danny BluesteinDanny Bluestein
Danny Bluestein
The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)—the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional model geometry of a straight conduit with sudden expansion distal the valves, including the valve housing and detailed hinge geometry. An aortic flow waveform (60 beats/min, cardiac output 4 l∕min) was applied at the inlet. The FSI formulation utilized a fully implicit coupling procedure using a separate solver for the fluid problem (FLUENT ) and for the structural problem. Valve leaflet excursion and pressure differences were calculated, as well as shear stress on the leaflets and accumulated shear stress on particles released during both forward and backward flow phases through the open and closed valve, respectively. In contrast to the SJM, the ATS valve opened to less than maximal opening angle. Nevertheless, maximal and mean pressure gradients and velocity patterns through the valve orifices were comparable. Platelet stress accumulation during forward flow indicated that no platelets experienced a stress accumulation higher than 35 dyne×s/cm2 , the threshold for platelet activation (Hellums criterion). However, during the regurgitation flow phase, 0.81% of the platelets in the SJM valve experienced a stress accumulation higher than 35 dyne×s/cm2 , compared with 0.63% for the ATS valve. The numerical results indicate that the designs of the ATS and SJM valves, which differ mostly in their hinge mechanism, lead to different potential for platelet activation, especially during the regurgitation phase. This numerical methodology can be used to assess the effects of design parameters on the flow induced thrombogenic potential of blood recirculating devices.

20 November 2018 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
MBMatteo Bianchi
Matteo Bianchi
GMGil Marom
Gil Marom
RGRam P. Ghosh
Ram P. Ghosh
OROren M. Rotman
Oren M. Rotman
PPPuja Parikh
Puja Parikh
Danny BluesteinDanny Bluestein
Danny Bluestein

31 December 2008 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
PRPeter Rissland
Peter Rissland
YAYared Alemu
Yared Alemu
SEShmuel Einav
Shmuel Einav
JRJohn Ricotta
John Ricotta
Danny BluesteinDanny Bluestein
Danny Bluestein
Abdominal aortic aneurysm (AAA) rupture represents a major cardiovascular risk, combining complex vascular mechanisms weakening the abdominal artery wall coupled with hemodynamic forces exerted on the arterial wall. At present, a reliable method to predict AAA rupture is not available. Recent studies have introduced fluid structure interaction (FSI) simulations using isotropic wall properties to map regions of stress concentrations developing in the aneurismal wall as a much better alternative to the current clinical criterion, which is based on the AAA diameter alone. A new anisotropic material model of AAA that closely matches observed biomechanical AAA material properties was applied to FSI simulations of patient-specific AAA geometries in order to develop a more reliable predictor for its risk of rupture. Each patient-specific geometry was studied with and without an intraluminal thrombus (ILT) using two material models—the more commonly used isotropic material model and an anisotropic material model—to delineate the ILT contribution and the dependence of stress distribution developing within the aneurismal wall on the material model employed. Our results clearly indicate larger stress values for the anisotropic material model and a broader range of stress values as compared to the isotropic material, indicating that the latter may underestimate the risk of rupture. While the locations of high and low stresses are consistent in both material models, the differences between the anisotropic and isotropic models become pronounced at large values of strain—a range that becomes critical when the AAA risk of rupture is imminent. As the anisotropic model more closely matches the biomechanical behavior of the AAA wall and resolves directional strength ambiguities, we conclude that it offers a more reliable predictor of AAA risk of rupture.

12 February 2013 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Jawaad SheriffJawaad Sheriff
Jawaad Sheriff
JSJoão Silva Soares
João Silva Soares
Michalis XenosMichalis Xenos
Michalis Xenos
JJJolyon Jesty
Jolyon Jesty
Danny BluesteinDanny Bluestein
Danny Bluestein