Jawaad Sheriff

Dr. Jawaad Sheriff

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2008 in ASAIO Journal
Verified
Journal Article
Closed access
MNMatteo Nobili
Matteo Nobili
Jawaad SheriffJawaad Sheriff
Jawaad Sheriff
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
ARAlberto Redaelli
Alberto Redaelli
DBDanny Bluestein
Danny Bluestein
The need to optimize the thrombogenic performance of blood recirculating cardiovascular devices, e.g., prosthetic heart valves (PHV) and ventricular assist devices (VAD), is accentuated by the fact that most of them require lifelong anticoagulation therapy that does not eliminate the risk of thromboembolic complications. The formation of thromboemboli in the flow field of these devices is potentiated by contact with foreign surfaces and regional flow phenomena that stimulate blood clotting, especially platelets. With the lack of appropriate methodology, device manufacturers do not specifically optimize for thrombogenic performance. Such optimization can be facilitated by formulating a robust numerical methodology with predictive capabilities of flow-induced platelet activation. In this study, a phenomenological model for platelet cumulative damage, identified by means of genetic algorithms (GAs), was correlated with in vitro experiments conducted in a Hemodynamic Shearing Device (HSD). Platelets were uniformly exposed to flow shear representing the lower end of the stress levels encountered in devices, and platelet activity state (PAS) was measured in response to six dynamic shear stress waveforms representing repeated passages through a device, and correlated to the predictions of the damage accumulation model. Experimental results demonstrated an increase in PAS with a decrease in “relaxation” time between pulses. The model predictions were in very good agreement with the experimental results.

5 February 2010 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Jawaad SheriffJawaad Sheriff
Jawaad Sheriff
DBDanny Bluestein
Danny Bluestein
GGGaurav Girdhar
Gaurav Girdhar
JJJolyon Jesty
Jolyon Jesty

12 February 2013 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Jawaad SheriffJawaad Sheriff
Jawaad Sheriff
JSJoão Silva Soares
João Silva Soares
Michalis XenosMichalis Xenos
Michalis Xenos
JJJolyon Jesty
Jolyon Jesty
Danny BluesteinDanny Bluestein
Danny Bluestein

29 January 2013 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
JSJoão S. Soares
João S. Soares
Jawaad SheriffJawaad Sheriff
Jawaad Sheriff
Danny BluesteinDanny Bluestein
Danny Bluestein

1 February 2013 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
TCThomas E. Claiborne
Thomas E. Claiborne
Jawaad SheriffJawaad Sheriff
Jawaad Sheriff
MKMaximilian Kuetting
Maximilian Kuetting
USUlrich Steinseifer
Ulrich Steinseifer
MSMarvin J. Slepian
Marvin J. Slepian
Danny BluesteinDanny Bluestein
Danny Bluestein
Calcific aortic valve disease is the most common and life threatening form of valvular heart disease, characterized by stenosis and regurgitation, which is currently treated at the symptomatic end-stages via open-heart surgical replacement of the diseased valve with, typically, either a xenograft tissue valve or a pyrolytic carbon mechanical heart valve. These options offer the clinician a choice between structural valve deterioration and chronic anticoagulant therapy, respectively, effectively replacing one disease with another. Polymeric prosthetic heart valves (PHV) offer the promise of reducing or eliminating these complications, and they may be better suited for the new transcatheter aortic valve replacement (TAVR) procedure, which currently utilizes tissue valves. New evidence indicates that the latter may incur damage during implantation. Polymer PHVs may also be incorporated into pulsatile circulatory support devices such as total artificial heart and ventricular assist devices that currently employ mechanical PHVs. Development of polymer PHVs, however, has been slow due to the lack of sufficiently durable and biocompatible polymers. We have designed a new trileaflet polymer PHV for surgical implantation employing a novel polymer—xSIBS—that offers superior bio-stability and durability. The design of this polymer PHV was optimized for reduced stresses, improved hemodynamic performance, and reduced thrombogenicity using our device thrombogenicity emulation (DTE) methodology, the results of which have been published separately. Here we present our new design, prototype fabrication methods, hydrodynamics performance testing, and platelet activation measurements performed in the optimized valve prototype and compare it to the performance of a gold standard tissue valve. The hydrodynamic performance of the two valves was comparable in all measures, with a certain advantage to our valve during regurgitation. There was no significant difference between the platelet activation rates of our polymer valve and the tissue valve, indicating that similar to the latter, its recipients may not require anticoagulation. This work proves the feasibility of our optimized polymer PHV design and brings polymeric valves closer to clinical viability.

27 March 2015 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
VMValerie M. Merkle
Valerie M. Merkle
DMDaniel Martin
Daniel Martin
MHMarcus Hutchinson
Marcus Hutchinson
PTPhat L. Tran
Phat L. Tran
ABAlana Behrens
Alana Behrens
Marvin SlepianMarvin Slepian
Marvin Slepian