This paper presents a mathematical model of carbon nanotubes-based mediatorless biosensor. The developed model is based on nonlinear non-stationary reaction-diffusion equations. The model involves four layers (compartments): a layer of enzyme solution entrapped on a terylene membrane, a layer of the single walled carbon nanotubes deposited on a perforated membrane, and an outer diffusion layer. The biosensor response and sensitivity are investigated by changing the model parameters with a special emphasis on the mediatorless transfer of the electrons in the layer of the enzyme-loaded carbon nanotubes. The numerical simulation at transient and steady state conditions was carried out using the finite difference technique. The mathematical model and the numerical solution were validated by experimental data. The obtained agreement between the simulation results and the experimental data was admissible at different concentrations of the substrate.
20 January 2009 in Nonlinear Analysis Modelling and Control
This paper presents one-dimensional (1-D) and two-dimensional (2-D) in-space mathematical models for amperometric biosensors with an outer perforated membrane. The biosensor action was modelled by reaction-diffusion equations with a nonlinear term representing the Michaelis-Menten kinetics of an enzymatic reaction. The conditions at which the 1-D model can be applied to simulate the biosensor response accurately were investigated numerically. The accuracy of the biosensor response simulated by using 1-D model was evaluated by the response simulated with the corresponding 2-D model. A procedure for a numerical evaluation of the effective diffusion coefficient to be used in 1-D model was proposed. The numerically calculated effective diffusion coefficient was compared with the corresponding coefficients derived analytically. The numerical simulation was carried out using the finite difference technique.
24 December 2010 in Journal of Mathematical Chemistry
We present a quaterthiophene and sexithiophene that can reversibly change their effective π‐conjugation length through photoexcitation. The reported compounds make use of light‐responsive molecular actuators consisting of an azobenzene attached to a bithiophene unit by both direct and linker‐assisted bonding. Upon exposure to 350 nm light, the azobenzene undergoes trans‐to‐cis isomerization, thus mechanically inducing the oligothiophene to assume a planar conformation (extended π‐conjugation). Exposure to 254 nm wavelength promotes azobenzene cis‐to‐trans isomerization, forcing the thiophenic backbones to twist out of planarity (confined π‐conjugation). Twisted conformations are also reached by cis‐to‐trans thermal relaxation at a rate that increases proportionally with the conjugation length of the oligothiophene moiety. The molecular conformations of quaterthiophene and sexithiophene were characterized by using steady‐state UV‐vis spectroscopy, X‐ray crystallography and quantum‐chemical modeling. Finally, we tested the proposed light‐responsive oligothiophenes in field‐effect transistors to probe the photo‐induced tuning of their electronic properties.
In this paper, an amperometric glucose biosensor is modeled numerically. The model is based on non-stationary reaction-diffusion type equations. The model consists of four layers. An enzyme layer lies directly on a working electrode surface. The enzyme layer is attached to an electrode by a polyvinyl alcohol (PVA) coated terylene membrane. This membrane is modeled as a PVA layer and a terylene layer, which have different diffusivities. The fourth layer of the model is the diffusion layer, which is modeled using the Nernst approach. The system of partial differential equations is solved numerically using the finite difference technique. The operation of the biosensor was analyzed computationally with special emphasis on the biosensor response sensitivity to oxygen when the experiment was carried out in aerobic conditions. Particularly, numerical experiments show that the overall biosensor response sensitivity to oxygen is insignificant. The simulation results qualitatively explain and confirm the experimentally observed biosensor behavior.
In this study, the nonlinear and non-monotonic behavior of amperometric bienzyme biosensors employing an enzymatic trigger reaction is investigated analytically and computationally using a two-compartment model comprising an enzymatic layer and an outer diffusion layer. The trigger enzymatic reaction is coupled with a cyclic electrochemical–enzymatic conversion (CEC) process. The model is formulated as a system of reaction–diffusion equations incorporating nonlinear Michaelis–Menten kinetics and interlayer partitioning effects. Exact steady-state analytical solutions for substrate and product concentrations, as well as for the output current, are obtained for specific cases of first- and zero-order reaction kinetics. At the transition conditions, biosensor performance is further analyzed numerically using the finite difference method. The CEC biosensor exhibits the highest signal gain when the first enzyme has low activity and the second enzyme has high activity; however, under these conditions, the response time is the longest. When the first enzyme possesses a higher substrate affinity (lower Michaelis constant) than the second, the biosensor demonstrates severalfold higher current and gain compared to the reverse configuration under identical diffusion limitations. Furthermore, increasing external mass transport resistance or interfacial partitioning can enhance the apparent signal gain.