Austenitic stainless steels that exhibit good corrosion resistance have recently found increasing applications in industry and transportation. This article addresses the influence of cold rolling and deformation on the pitting corrosion resistance of AISI 301LN and 316L stainless steels. The results indicate that the content of martensite increases as the cold rolling reduction also increases. The current work combined different techniques such as optical microscopy and scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS) analyses. Corrosion tests were carried out, in accordance with the ASTM standards. The results confirm that the 316L steel performed better than the 301LN, regarding pitting corrosion, even when deformed. This is due to the high molybdenum (Mo) content, which guarantees greater corrosion resistance. The conducted corrosion tests showed that the increase of cold deformation reduces the resistance to pitting and overall corrosion in both steels. It was found that the 301LN stainless steel has higher susceptibility to deformation-induced martensite and, despite the addition of nitrogen, it still has a lower performance relative to the 316L steel. The current work focused on evaluating the formation of pits and the dynamics of the microstructures of the AISI 301LN and 316L steels with their mechanical properties and corrosion resistance in a saline environment including chlorides.
17 April 2024 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Hydrogen is gaining prominence as a clean energy vector, yet its extreme flammability demands robust detection solutions for industrial safety. In this study, we present the development and experimental validation of a microwave hydrogen gas sensor based on a patch-type microstrip antenna with a silver sensing element. The device operates at 5.99 GHz and was tested under controlled environmental conditions (humidity: 20 ± 0.4%, temperature: 27 ± 0.2 °C). Hydrogen exposure induces measurable shifts in the antenna’s resonant frequency due to dielectric modulation of the silver layer. The sensor exhibited a linear sensitivity of 3 kHz/ppm in the 310–600 ppm concentration range, with a residual standard deviation of 31.1 kHz and a calculated limit of detection (LOD) of approximately 31 ppm. The reflection coefficient remained below −10 dB throughout, confirming that the antenna maintains functional RF performance during sensing. These results demonstrate the sensor’s dual functionality for gas detection and communication, offering a compact and scalable platform for hydrogen safety monitoring.
Uma empresa de embarque de cargas, situada em Maringá-PR, passou por uma auditoria externa, após a mesma observou-se a necessidade da elaboração de um plano de ação para reduzir os efeitos de não-conformidades da empresa com seus clientes. Para reduzir o número de notificações foi preciso analisar as principais “não-conformidades” mediante análise crítica da auditoria, voltado ao plano de ação preventivo e não corretivo. Assim, o presente trabalho relacionou a confecção de plano de ação visando a ação preventiva e posterior sugestão de uma matriz para diagnosticar os riscos perante a norma neozelandesa - AS NZS 4360-1999 Risk management e ABNT ISO 3100:2009. Desta forma foi possível criar um método inovador para a gestão de segurança da embarcadora de cargas, na qual se tem ciência das gravidades e consequências dos principais riscos que circundam as atividades da empresa, trazendo assim foco e concentração de estudos futuros para execução de serviços.