Implementation of environmental cleaning and disinfection has been shown to reduce the incidences of healthcare-associated infections. The effect of an enhanced strategy for terminal room disinfection, applying the pulsed xenon-based ultraviolet light no-touch disinfection systems (PX-UVC) after the current standard operating protocol (SOP) was evaluated. In a teaching hospital, the effectiveness in reducing the total bacterial count (TBC) and in eliminating high-concern microorganisms was assessed on five high-touch surfaces in different critical areas, immediately pre- and post-cleaning and disinfection procedures (345 sampling sites). PX-UVC showed only 18% (15/85) of positive samples after treatment compared to 63% (72/115) after SOP. The effectiveness of PX-UVC was also observed in the absence of manual cleaning and application of a chemical disinfectant. According to the hygienic standards proposed by the Italian Workers Compensation Authority, 9 of 80 (11%) surfaces in operating rooms showed TBC ≥15 CFU/24 cm2 after the SOP, while all samples were compliant applying the SOP plus PX-UVC disinfection. Clostridium difficile (CD) spores and Klebsiella pneumoniae (KPC) were isolated only after the SOP. The implementation of the standard cleaning and disinfection procedure with the integration of the PX-UVC treatment had effective results in both the reduction of hygiene failures and in control environmental contamination by high-concern microorganisms.
1 August 2013 in Antimicrobial Agents and Chemotherapy
Infections caused by carbapenem-resistant KPC-producing Klebsiella pneumoniae are responsible for high rates of mortality and represent a major therapeutic challenge, especially when the isolates are also resistant to colistin. We used the checkerboard method to evaluate the synergistic activity of 10 antibiotic combinations against 13 colistin-resistant KPC-producing K. pneumoniae isolates (colistin MIC range of 8 to 128 mg/liter). Colistin plus rifampin was the only combination that demonstrated consistent synergistic bacteriostatic activity against 13/13 strains tested, reducing the colistin MIC below the susceptibility breakpoint (MIC ≤ 2 mg/liter) in 7/13 strains at rifampin concentrations ranging from 4 to 16 mg/liter. Bactericidal synergistic activity was also documented for 8/13 tested strains. Other antimicrobial combinations with carbapenems, gentamicin, and tigecycline showed variously synergistic results. Colistin plus rifampin also exhibited bacteriostatic synergistic activity against 4/4 colistin-susceptible KPC-producing K. pneumoniae isolates (colistin MIC range of 0.5 to 2 mg/liter) and 4/4 ertapenem-resistant extended-spectrum beta-lactamase (ESBL)-producing K. pneumoniae isolates (ertapenem MIC range of 16 to 32 mg/liter). Collectively, our data suggest that colistin plus rifampin is the most consistently synergistic combination against KPC-producing K. pneumoniae isolates, including colistin-resistant strains. Colistin-rifampin combinations may have a role in the treatment of multidrug-resistant K. pneumoniae and may possibly slow the selection of heteroresistant subpopulations during colistin therapy.
The role of microplastics (MPs) in the spread of antibiotic resistance genes (ARGs) is increasingly attracting global research attention due to their unique ecological and environmental effects. The ubiquitous use of plastics and their release into the environment by anthropic/industrial activities are the main sources for MP contamination, especially of water bodies. Because of their physical and chemical characteristics, MPs represent an ideal substrate for microbial colonization and formation of biofilm, where horizontal gene transfer is facilitated. In addition, the widespread and often injudicious use of antibiotics in various human activities leads to their release into the environment, mainly through wastewater. For these reasons, wastewater treatment plants, in particular hospital plants, are considered hotspots for the selection of ARGs and their diffusion in the environment. As a result, the interaction of MPs with drug-resistant bacteria and ARGs make them vectors for the transport and spread of ARGs and harmful microorganisms. Microplastic-associated antimicrobial resistance is an emerging threat to the environment and consequently for human health. More studies are required to better understand the interaction of these pollutants with the environment as well as to identify effective management systems to reduce the related risk.
A carbapenem-sparing regimen of tigecycline plus gentamicin or colistin was effective for treating 24 of 26 (92%) Klebsiella pneumoniae carbapenemase–producing K. pneumoniae infectious episodes in 22 polytrauma intensive care unit patients without comorbidities. The 30-day crude mortality rate was 14%. Regimens were considered appropriate in 12% of episodes according to the Vitek 2 System and in 100% based on E-test.
1 March 2014 in Infection Control & Hospital Epidemiology
Objective and Design.: Legionellacontrol still remains a critical issue in healthcare settings where the preferred approach to health risk assessment and management is to develop a water safety plan. We report the experience of a university hospital, where a water safety plan has been applied since 2002, and the results obtained with the application of different methods for disinfecting hot water distribution systems in order to provide guidance for the management of water risk.Interventions.: The disinfection procedures included continuous chlorination with chlorine dioxide (0.4–0.6 mg/L in recirculation loops) reinforced by endpoint filtration in critical areas and a water treatment based on monochloramine (2-3 mg/L). Real-time polymerase chain reaction and a new immunoseparation and adenosine triphosphate bioluminescence analysis were applied in environmental monitoring.Results.: After 9 years, the integrated disinfection-filtration strategy significantly reduced positive sites by 55% and the mean count by 78% (P< .05); however, the high costs and the occurrence of a chlorine-tolerant clone belonging toLegionella pneumophilaST269 prompted us to test a new disinfectant. The shift to monochloramine allowed us to eliminate planktonicLegionellaand did not require additional endpoint filtration; however, nontuberculous mycobacteria were isolated more frequently as long as the monochloramine concentration was 2 mg/L; their cultivability was never regained by increasing the concentration up to 3 mg/L.Conclusions.: Any disinfection method needs to be adjusted/fine-tuned in individual hospitals in order to maintain satisfactory results over time, and only a locally adapted evidence-based approach allows assessment of the efficacy and disadvantages of the control measures.