Implementation of environmental cleaning and disinfection has been shown to reduce the incidences of healthcare-associated infections. The effect of an enhanced strategy for terminal room disinfection, applying the pulsed xenon-based ultraviolet light no-touch disinfection systems (PX-UVC) after the current standard operating protocol (SOP) was evaluated. In a teaching hospital, the effectiveness in reducing the total bacterial count (TBC) and in eliminating high-concern microorganisms was assessed on five high-touch surfaces in different critical areas, immediately pre- and post-cleaning and disinfection procedures (345 sampling sites). PX-UVC showed only 18% (15/85) of positive samples after treatment compared to 63% (72/115) after SOP. The effectiveness of PX-UVC was also observed in the absence of manual cleaning and application of a chemical disinfectant. According to the hygienic standards proposed by the Italian Workers Compensation Authority, 9 of 80 (11%) surfaces in operating rooms showed TBC ≥15 CFU/24 cm2 after the SOP, while all samples were compliant applying the SOP plus PX-UVC disinfection. Clostridium difficile (CD) spores and Klebsiella pneumoniae (KPC) were isolated only after the SOP. The implementation of the standard cleaning and disinfection procedure with the integration of the PX-UVC treatment had effective results in both the reduction of hygiene failures and in control environmental contamination by high-concern microorganisms.
Introduction: Dental Unit Waterlines (DUWLs) have shown to be a source of Legionella infection. We report the experience of different dental healthcare settings where a risk management plan was implemented. Materials and methods: In a Hospital Odontostomatology Clinic (HOC) and three Private Dental Clinics (PDCs) housing 13 and six dental units (DUs), respectively, an assessment checklist was applied to evaluate staff compliance with guideline recommendations. DUWLs microbial parameters were investigated before and after the application of corrective actions. Results: In the HOC a poor adherence to good practices was demonstrated, whereas protocols were carefully applied in PDCs. L. pneumophila sg 2–15 was isolated in 31% (4/13) and 33% (2/6) of DUs in HOC and PDCs, respectively, mainly from handpieces (32%, 6/19) with counts >102 colony-forming units per milliliter (CFU/L), often associated with P. aeruginosa (68%, 13/19). The shock disinfection with 3% v/v hydrogen peroxide (HP) showed a limited effect, with a recolonization period of about 4 weeks. Legionella was eradicated only after 6% v/v HP shock disinfection and filters-installation, whilst P. aeruginosa after the third shock disinfection with a solution of 4% v/v HP and biodegradable surfactants. Conclusions: Our data demonstrate the presence and persistence of microbial contamination within the DUWLs, which required strict adherence to control measures and the choice of effective disinfectants.
Studies conducted over the last 40 years have demonstrated that the water output from dental unit waterlines (DUWLs) is often contaminated with high densities of microorganisms. It has been monitored the microbiological quality of the water in 30 public dental facilities in northern Italy in order to assess the health risk for patients and dental staff. In each facility, samples of water both from taps and from DUWLs were analyzed in order to evaluate heterotrophic plate counts (HPCs) at 22 °C and 36 °C, and to detect coliform bacteria, Pseudomonas aeruginosa, Legionella pneumophila and amoebae. In 100% of the samples taken from the DUWLs, the concentration of HPCs was above the threshold as determined by the Ministère de la Santé et des Solidarités (2007). The concentration of P. aeruginosa was greater than the indicated threshold in 16.67% of the hand-pieces analyzed. A total of 78.33% of samples were contaminated by L. pneumophila, while in the samples taken from the DUWLs alone, this percentage rose to 86.67%. Amoebae were detected in 60% of the samples taken from hand-pieces; all belonging to the species V. vermiformis. This study documented the presence of various microorganisms, including Legionella spp., at considerably higher concentrations in water samples from DUWLs than in samples of tap water in the same facilities, confirming the role of the internal DUWLs in increasing microbial contamination, especially in the absence of proper management of waterborne health risks.
Objectives: To evaluate the effectiveness of hydrogen peroxide (HP) use as a disinfectant in the hospital water network for the control of Legionella spp. colonization. Methods: Following the detection of high levels of Legionella contamination in a 136-bed general hospital water network, an HP treatment of the hot water supply (25 mg/L) was adopted. During a period of 34 months, the effectiveness of HP on Legionella colonization was assessed. Legionella was isolated in accordance with ISO-11731 and identification was carried out by sequencing of the mip gene. Results: Before HP treatment, L. pneumophila sg 2–15 was isolated in all sites with a mean count of 9950 ± 8279 cfu/L. After one-month of HP treatment, we observed the disappearance of L. pneumophila 2–15, however other Legionella species previously not seen were found; Legionellapneumophila 1 was isolated in one out of four sampling sites (2000 cfu/L) and other non-pneumophila species were present in all sites (mean load 3000 ± 2887 cfu/L). Starting from September 2013, HP treatment was modified by adding food-grade polyphosphates, and in the following months, we observed a progressive reduction of the mean load of all species (p < 0.05), resulting in substantial disappearance of Legionella colonization. Conclusion: Hydrogen peroxide demonstrated good efficacy in controlling Legionella. Although in the initial phases of treatment it appeared unable to eliminate all Legionella species, by maintaining HP levels at 25 mg/L and adding food-grade polyphosphates, a progressive and complete control of colonization was obtained.
The emergence of multiresistant bacterial strains as agents of healthcare-related infection in hospitals has prompted a review of the control techniques, with an added emphasis on preventive measures, namely good clinical practices, antimicrobial stewardship, and appropriate environmental cleaning. The latter item is about the choice of an appropriate disinfectant as a critical role due to the difficulties often encountered in obtaining a complete eradication of environmental contaminations and reservoirs of pathogens. The present review is focused on the effectiveness of hydrogen peroxide vapor, among the new environmental disinfectants that have been adopted. The method is based on a critical review of the available literature on this topic
A viral spread occurrence such as the SARS-CoV-2 pandemic has prompted the evaluation of different disinfectants suitable for a wide range of environmental matrices. Chlorine dioxide (ClO2) represents one of the most-used virucidal agents in different settings effective against both enveloped and nonenveloped viruses. This narrative synthesis is focused on the effectiveness of ClO2 applied in healthcare and community settings in order to eliminate respiratory transmitted, enteric, and bloodborne viruses. Influenza viruses were reduced by 99.9% by 0.5–1.0 mg/L of ClO2 in less than 5 min. Higher concentration (20 mg/L) eliminated SARS-CoV-2 from sewage. ClO2 concentrations from 0.2 to 1.0 mg/L ensured at least a 99% viral reduction of AD40, HAV, Coxsackie B5 virus, and other enteric viruses in less than 30 min. Considering bloodborne viruses, 30 mg/L of ClO2 can eliminate them in 5 min. Bloodborne viruses (HIV-1, HCV, and HBV) may be completely eliminated from medical devices and human fluids after a treatment with 30 mg/L of ClO2 for 30 min. In conclusion, ClO2 is a versatile virucidal agent suitable for different environmental matrices.