OBJECTIVE: Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery. RESEARCH DESIGN AND METHODS: We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL). RESULTS: We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (<1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%. CONCLUSIONS: Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.
Aim: To compare clinical baseline data in individuals with Type 2 diabetes and normoalbuminuria, who are at high or low risk of diabetic kidney disease based on the urinary proteomics classifier CKD273.Methods: We conducted a prospective, randomized, double‐blind, placebo‐controlled international multicentre clinical trial and observational study in participants with Type 2 diabetes and normoalbuminuria, stratified into high‐ or low‐risk groups based on CKD273 score. Clinical baseline data for the whole cohort and stratified by risk groups are reported. The associations between CKD273 and traditional risk factors for diabetic kidney disease were evaluated using univariate and logistic regression analysis.Results: A total of 1777 participants from 15 centres were included, with 12.3% of these having a high‐risk proteomic pattern. Participants in the high‐risk group (n=218), were more likely to be men, were older, had longer diabetes duration, a lower estimated GFR and a higher urinary albumin:creatinine ratio than those in the low‐risk group (n=1559, P<0.02). Numerical differences were small and univariate regression analyses showed weak associations (R2 < 0.04) of CKD273 with each baseline variable. In a logistic regression model including clinical variables known to be associated with diabetic kidney disease, estimated GFR, gender, log urinary albumin:creatinine ratio and use of renin‐angiotensin system‐blocking agents remained significant determinants of the CKD273 high‐risk group: area under the curve 0.72 (95% CI 0.68–0.75; P<0.01).Conclusions: In this population of individuals with Type 2 diabetes and normoalbuminuria, traditional diabetic kidney disease risk factors differed slightly between participants at high risk and those at low risk of diabetic kidney disease, based on CKD273. These data suggest that CKD273 may provide additional prognostic information over and above the variables routinely available in the clinic. Testing the added value will be subject to our ongoing study. (European Union Clinical Trials Register: EudraCT 2012‐000452‐34 and Clinicaltrials.gov: NCT02040441).
Digital image analysis (DIA) is a new method in assessment of islet amount, which is expected to provide reliable and consistent results. We compared this method with conventional counting of small numbers of rat islets. Islets were isolated from 8 pancreases and counted in 24 samples in duplicate, first routinely by sizing according to estimated diameters under a calibrated reticule and then by processing of islets pictures taken by camera. As presumed, no significant difference was found in absolute numbers of islets per sample between DIA and conventional assessment. Volumes of islets per sample measured by DIA were on average more than 10% higher than amounts evaluated conventionally, which was statistically significant. DIA has been shown to be an important method to remove operator bias and provide consistent results. Evaluation of only two dimensions of three-dimensional objects still represents a certain limitation of this technique. With lowering of computer prices the system could become easily available for islet laboratories.
27 September 2019 in American Journal of Transplantation
The study was aimed to compare pancreas graft survival rates in 2 groups of pancreas and kidney transplant recipients prospectively randomized to treatment either with sirolimus or MMF. From 2002 to 2013, 238 type 1 diabetic recipients with end‐stage kidney disease were randomized 1:1 to sirolimus or MMF treatment. Non‐censored pancreas survival at 5 years was 76.4 and 71.6 % for Sirolimus and MMF groups, respectively (p > 0.05). Death censored pancreas survival was better in the Sirolimus group (p=0.037). After removal of early graft losses pancreas survival did not differ between groups (MMF 83.1% vs Sirolimus 91.6%, p=0.11). Non‐significantly more grafts were lost due to rejection in the MMF group (10 vs 5; p=0.19). Cumulative patient 5‐year survival was 96 % in the MMF group and 91 % in the Sirolimus group (p>0.05). Five year cumulative non‐censored kidney graft survival rates did not statistically differ (85.6% in Sirolimus group and 88.8% in MMF group) Recipients treated with MMF had significantly more episodes of gastrointestinal bleeding (7 vs 0, p=0.007). More recipients in the sirolimus group required corrective surgery due to incisional hernias (21 vs 12, p=0.019).
Infusing pancreatic islets into the portal vein currently represents the preferred approach for islet transplantation, despite considerable loss of islet mass almost immediately after implantation. Therefore, approaches that obviate direct intravascular placement are urgently needed. A promising candidate for extrahepatic placement is the omentum. We aimed to develop an extracellular matrix skeleton from the native pancreas that could provide a microenvironment for islet survival in an omental flap. To that end, we compared different decellularization approaches, including perfusion through the pancreatic duct, gastric artery, portal vein, and a novel method through the splenic vein. Decellularized skeletons were compared for size, residual DNA content, protein composition, histology, electron microscopy, and MR imaging after repopulation with isolated islets. Compared to the other approaches, pancreatic perfusion via the splenic vein provided smaller extracellular matrix skeletons, which facilitated transplantation into the omentum, without compromising other requirements, such as the complete depletion of cellular components and the preservation of pancreatic extracellular proteins. Repeated MR imaging of iron-oxide-labeled pancreatic islets showed that islets maintained their position in vivo for 49 days. Advanced environmental scanning electron microscopy demonstrated that islets remained integrated with the pancreatic skeleton. This novel approach represents a proof-of-concept for long-term transplantation experiments.