High penetration of renewable energy sources (RES) leads to new challenges for protection devices. Protection schemes are typically designed according to the dynamic behavior of rotating machines as generation sources, while the RES dynamic response, mainly governed by inverters, is not considered. Consequently, some relevant algorithms of transmission line protection are experiencing challenges because of the fact that magnitude and phase angle comparison, amount of negative-sequence, and short-circuit current level are affected by the RES. Therefore, an in-depth study of this issue is necessary, one which considers the main causes and new methodological criteria solutions. This work presents an extensive literature review of the evaluation of electrical protection performance and the effects of RES connected to a power grid through inverters. Bibliographic data on many representative publications related to this topic are obtained to show the current research lines and their proposed solutions. In addition, this work identifies the main protection functions affected and describes the new protection schemes that consider RES. Finally, an analysis and discussion of the selected bibliography are presented.
1 April 2023 in Protection and Control of Modern Power Systems
The ongoing transformation of electrical power systems highlights the weaknesses of the protection schemes of traditional devices because they are designed and configured according to traditional characteristics of the system. Therefore, this work proposes a new methodology to study the fault-generated high frequency transient signals in transmission lines through multiresolution analysis. The high frequency components are determined by a new digital filtering technique based on mathematical morphology theory and a spectral energy index. Consequently, wide spectra of signals in the time–frequency domain are obtained. The performance of this method is verified on an electrical power system modeled in ATP-Draw, where simulation and test signals are developed for different locations, fault resistances, inception angles, high frequency noises, sampling frequencies, types of faults, and shapes of the structuring element. The results show the characteristics of the fault such as the traveling wave frequency, location, and starting time.
12 January 2023 in Clean Technologies and Environmental Policy
The Ultra-high-speed and simplicity of protection schemes have been a subject of study in recent years. Therefore this document develop a differential protection method in transmission lines using voltage and current traveling waves signals, where the transmission lines are modeled through distributed parameters and expressed by telegraph's equations which is solved using Bergeron's equations, these equations depend on instantaneous signals and historical components. Using an error index that compares the voltage and current signals from the line ends, the fault is detected. Furthermore, signals with synchronized measurements with the same time stamp are considered. This method uses simple criteria and fast operation time, because it uses algebraic operations and a time window between 1 and 2 ms. A power system is modeled on ATPDraw and many faults cases are simulated; several conditions such as inception angle from voltage signal, fault resistance, fault distance and internal/external faults are considered. In the case of three-phase systems, the use of Clarke's modal decomposition is proposed. Good results in the operation are obtained and comparing with traditional algorithms this method presents low operating times.
Electrification of Peru's rural areas is an issue of vital importance for economic growth. However, these areas still have poor quality electricity service or operate in a stand-alone mode with high cost of energy. To address this problem, one of the most promising strategies proposes the use of renewable energy technologies through the implementation of microgrids. In this context, this research develops the analysis of 37 cases of rural villages throughout Peru in order to obtain the optimal microgrid design and the most feasible areas for its implementation, considering the associated costs, geographic location, and load characteristics. For this purpose, an optimization process is carried out using Homer Pro software with the aim of sizing the microgrid with the minimum net present cost and cost of energy. Then, an iterative process is developed in Matlab software to map cost values, renewable contribution, emissions, the energy charge and the annual savings in the utility bill. This analysis considers five scenarios base on a grid-connected microgrid (with sensitivity values of grid sellback price) and an off-grid microgrid system. The results show the geographic distribution of all the annual utility saving bill. For the grid-connected microgrid condition, it presents a profit in the range of $107.08 to $368.2 compared to loads connected to the grid; while, for the off-grid microgrid condition, it presents a profit in the range of $1269 to $4976 in comparison with loads connected to a diesel generator.
The growth of modern clean generation technologies brings with it significant benefits, but it also brings with it certain challenges, such as proper energy management. This has given rise to the emergence of microgrids whose basic design principle is an economical and efficient solution. In this sense, this work develops the model of a microgrid that includes a battery bank system and associated with a dynamic control scheme for proper energy management, this logic scheme is implemented and simulated in the Power Factory software for evaluation. The results obtained show an adequate behavior of the microgrid model for different scenarios of a real case study as an industrial demand located in a rural area, in the district of Navan, Lima, Peru, where a post-harvest processing of fruit trees is performed.