JOHN MORALES

Dr. JOHN MORALES


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2020 in IEEE Access
Verified
Journal Article
Open access
JMJOHN MORALES
JOHN MORALES
FQFlavio Quizhpi
Flavio Quizhpi
HVHector Villarroel-Gutierrez
Hector Villarroel-Gutierrez
EMEduardo Munoz
Eduardo Munoz
EOEduardo Orduna
Eduardo Orduna
EVErnesto Vasquez
Ernesto Vasquez
Impulse Response Coefficients (IRC) of digital filters is an imperative step in the development of transmission line protection relay algorithms. Traditionally, Fourier-based filters are used in real applications, where IRC are fixed values of sine and cosine functions with a data window of one or more cycles. Based on state-of-the-art, Mother Wavelet coefficients used in Multiresolution Analysis, and Structuring Element coefficients used in Mathematical Morphology are usually proposed to develop protection algorithms. However, the proper choice of these coefficients is based on empirical process of trial and error. This paper proposes a novel methodology for optimally determining coefficients that depend on the waveform structure analyzed, which is determined using variance as the metric. Assessment of methodology for three case studies considering requirements of relay manufactures (response time, design, harmonic attenuation and other) is presented. The first assessment is to extract coefficients useful for distinguishing among non-fault conditions, harmonics, and arcing faults. The second one is to extract coefficients to filter harmonic components. The assessment is carried out considering different data windows and sampling rates. Test results highlight the efficiency of the model to determine specific coefficients for each case study analyzed. Interestingly, results also showed that the discovered coefficients can be used in another filtering technique. Thus, the third case study involves developing two fault classifiers, which are developed using mathematical morphology where the structuring elements used correspond to the coefficient vectors determined through the proposed methodology. There is a notable paucity of scientific literature focusing on this topic. Therefore, there are several important areas where this study makes an original contribution regarding protection relays.


21 June 2021 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
JHJuan Carlos Quispe Huarcaya
Juan Carlos Quispe Huarcaya
JMJOHN MORALES
JOHN MORALES
EOEduardo Orduña
Eduardo Orduña
The Ultra-high-speed and simplicity of protection schemes have been a subject of study in recent years. Therefore this document develop a differential protection method in transmission lines using voltage and current traveling waves signals, where the transmission lines are modeled through distributed parameters and expressed by telegraph's equations which is solved using Bergeron's equations, these equations depend on instantaneous signals and historical components. Using an error index that compares the voltage and current signals from the line ends, the fault is detected. Furthermore, signals with synchronized measurements with the same time stamp are considered. This method uses simple criteria and fast operation time, because it uses algebraic operations and a time window between 1 and 2 ms. A power system is modeled on ATPDraw and many faults cases are simulated; several conditions such as inception angle from voltage signal, fault resistance, fault distance and internal/external faults are considered. In the case of three-phase systems, the use of Clarke's modal decomposition is proposed. Good results in the operation are obtained and comparing with traditional algorithms this method presents low operating times.

1 September 2026 in International Journal of Applied Power Engineering (IJAPE)
Verified
Journal Article
Open access
PDF file
AYAlvaro Yassif Marca Yucra
Alvaro Yassif Marca Yucra
GSGastón Orlando Suvire
Gastón Orlando Suvire
JMJOHN MORALES
JOHN MORALES
This article presents a multi-objective optimization methodology for the optimal tuning of passive power filters in steelmaking facilities that operate with electric arc furnaces (EAFs). These industrial loads are well-known for introducing severe harmonic distortion, voltage unbalance, and flicker into the electrical network, significantly degrading power quality and equipment performance. To address these challenges, a multi-objective optimization problem is solved using the non-dominated sorting genetic algorithm II (NSGA-II), which simultaneously minimizes three key power quality indices: total harmonic distortion (THD), total demand distortion (TDD), and voltage unbalance factor (VUF). In addition, a multi-criteria decision analysis (MCDA) technique is applied to rank and select the most balanced and robust solution in different EAF operating scenarios. Unlike conventional filter design methods that prioritize a single performance criterion or rely on static harmonic assumptions, the proposed approach accounts for the nonlinear and time-varying behavior of EAFs, ensuring robust performance under diverse operating conditions. A comprehensive case study based on a Bolivian steel plant illustrates the effectiveness of the optimization strategy. Results indicate reductions of 47.6% in THD, 33.5% in TDD, and 63.6% in VUF, clearly outperforming conventional design approaches and significantly improving overall power quality. This work highlights the potential of evolutionary multi-objective algorithms for enhancing passive filter performance in complex industrial environments with highly distorted and unbalanced power conditions.

15 April 2026 in Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL
Verified
Journal Article
Open access
PDF file
JBJosé Gerardo Moreno Bustos Moreno Bustos
José Gerardo Moreno Bustos Moreno Bustos
JMJOHN MORALES
JOHN MORALES
EOEduardo A. Orduña
Eduardo A. Orduña
Post-fault signal interpretation is a key responsibility of protection engineers and operations personnel, especially when the origin of a disturbance is not immediately evident. Traditionally, this task relies on the manual interpretation of COMTRADE-based oscillograms and phasor diagrams, which under complex or borderline conditions may be ambiguous and difficult to decode. A comprehensive review of the literature indicates that numerous approaches have been proposed for post-fault analysis, with particular emphasis on techniques based on the Fourier Transform and the Wavelet Transform. However, the effectiveness of these mathematical tools is highly sensitive to the choice of decomposition levels and basis functions, such as specific mother wavelets.This paper presents a novel visual methodology for offline post-event analysis, based on voltage incremental quantities and principal component analysis. It is specifically designed to assist human experts by projecting high-dimensional transient data into low-dimensional spaces where patterns become visually distinguishable. This dimensionality reduction allows engineers to identify and differentiate short-circuits from switching operation events, while also recognizing key fault characteristics such as fault resistance, inception angle, and involved phases.The methodology was validated using the Argentine Interconnection System at 500 kV simulated using the Alternative Tran-sients Program. Thus, a complementary diagnostic tool that enhances traditional methods by providing interpretable visual patterns is proposed. In doing so, it reduces the cognitive load on field engineers and enables faster, more informed decision-making.

15 April 2026 in Simposio Internacional sobre la Calidad de la Energía Eléctrica - SICEL
Verified
Journal Article
Open access
PDF file
AMAnthony Molina
Anthony Molina
RVRicardo Villacrés
Ricardo Villacrés
JMJOHN MORALES
JOHN MORALES
GSGastón Orlando Suvire
Gastón Orlando Suvire
The coordination of inverse-time overcurrent protection relays (51 relays) requires careful consideration to achieve an appropriate balance of selectivity, speed, and reliability when the system is subjected to faults. This study presents an evaluation of optimization algorithms using both linear and nonlinear programming methods available in Python’s SciPy library. The setting parameters considered are the Time Dial Setting (TDS), Pickup Setting (PS), and Time-Current Characteristic (TCC) curves, which must be efficiently configured. Several solvers were analyzed, including: highs, highs-ds, highs-ipm, simplex, revised simplex, interior-point, COBYLA, SLSQP, and trust-constr. Each was evaluated based on three criteria: relay operating time, sensitivity to fault current, and computational efficiency. The results indicate that the differences in total solver execution times are minimal, on the order of 1×10⁻⁷ seconds. However, highs-ipm and COBYLA demonstrated superior performance in terms of both speed and accuracy. Moreover, the inclusion of multiple setting parameters significantly enhances the overall effectiveness of the protection system. The study concludes that the optimal solver choice depends on the trade-off between computational time and solution accuracy. This research lays a strong foundation for future work involving the application of linear and nonlinear programming techniques in relay protection settings.