Rudi Penne

Prof. Rudi Penne

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SSSeppe Sels
Seppe Sels
BRBart Ribbens
Bart Ribbens
Steve VanlanduitSteve Vanlanduit
Steve Vanlanduit
Rudi PenneRudi Penne
Rudi Penne
In order to determine camera parameters, a calibration procedure involving the camera recordings of a checkerboard is usually performed. In this paper, we propose an alternative approach that uses Gray-code patterns displayed on an LCD screen. Gray-code patterns allow us to decode 3D location information of points of the LCD screen at every pixel in the camera image. This is in contrast to checkerboard patterns where the number of corresponding locations is limited to the number of checkerboard corners. We show that, for the case of a UEye CMOS camera, the precision of focal-length estimation is 1.5 times more precise than when using a standard calibration with a checkerboard pattern.

1 January 2020 in SoftwareX
Verified
Journal Article
Open access
BBBoris Bogaerts
Boris Bogaerts
SSSeppe Sels
Seppe Sels
Steve VanlanduitSteve Vanlanduit
Steve Vanlanduit
Rudi PenneRudi Penne
Rudi Penne

23 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Izaak Van CrombruggeIzaak Van Crombrugge
Izaak Van Crombrugge
SSSeppe Sels
Seppe Sels
BRBart Ribbens
Bart Ribbens
Gunther SteenackersGunther Steenackers
Gunther Steenackers
Rudi PenneRudi Penne
Rudi Penne
Steve VanlanduitSteve Vanlanduit
Steve Vanlanduit
To automatically evaluate the ergonomics of workers, 3D skeletons are needed. Most ergonomic assessment methods, like REBA, are based on the different 3D joint angles. Thanks to the huge amount of training data, 2D skeleton detectors have become very accurate. In this work, we test three methods to calculate 3D skeletons from 2D detections: using the depth from a single RealSense range camera, triangulating the joints using multiple cameras, and combining the triangulation of multiple camera pairs. We tested the methods using recordings of a person doing different assembly tasks. We compared the resulting joint angles to the ground truth of a VICON marker-based tracking system. The resulting RMS angle error for the triangulation methods is between 12° and 16°, showing that they are accurate enough to calculate a useful ergonomic score from.

16 April 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
BBBoris Bogaerts
Boris Bogaerts
SSSeppe Sels
Seppe Sels
Steve VanlanduitSteve Vanlanduit
Steve Vanlanduit
Rudi PenneRudi Penne
Rudi Penne
We develop a new gradient-based optimization strategy for robotic inspection planning. The algorithm starts from an initial measurement path and evolves this path to decrease path length while maintaining sensor coverage. The approach is powerful enough to handle inspection tasks of complex objects under articulated manipulator constraints. We show the effectiveness of the algorithm in two complex inspection tasks.

8 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SSSeppe Sels
Seppe Sels
BBBoris Bogaerts
Boris Bogaerts
Steve VanlanduitSteve Vanlanduit
Steve Vanlanduit
Rudi PenneRudi Penne
Rudi Penne
Currently, galvanometric scanning systems (like the one used in a scanning laser Doppler vibrometer) rely on a planar calibration procedure between a two-dimensional (2D) camera and the laser galvanometric scanning system to automatically aim a laser beam at a particular point on an object. In the case of nonplanar or moving objects, this calibration is not sufficiently accurate anymore. In this work, a three-dimensional (3D) calibration procedure that uses a 3D range sensor is proposed. The 3D calibration is valid for all types of objects and retains its accuracy when objects are moved between subsequent measurement campaigns. The proposed 3D calibration uses a Non-Perspective-n-Point (NPnP) problem solution. The 3D range sensor is used to calculate the position of the object under test relative to the laser galvanometric system. With this extrinsic calibration, the laser galvanometric scanning system can automatically aim a laser beam to this object. In experiments, the mean accuracy of aiming the laser beam on an object is below 10 mm for 95% of the measurements. This achieved accuracy is mainly determined by the accuracy and resolution of the 3D range sensor. The new calibration method is significantly better than the original 2D calibration method, which in our setup achieves errors below 68 mm for 95% of the measurements.

5 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Izaak Van CrombruggeIzaak Van Crombrugge
Izaak Van Crombrugge
Rudi PenneRudi Penne
Rudi Penne
Steve VanlanduitSteve Vanlanduit
Steve Vanlanduit
Knowledge of precise camera poses is vital for multi-camera setups. Camera intrinsics can be obtained for each camera separately in lab conditions. For fixed multi-camera setups, the extrinsic calibration can only be done in situ. Usually, some markers are used, like checkerboards, requiring some level of overlap between cameras. In this work, we propose a method for cases with little or no overlap. Laser lines are projected on a plane (e.g., floor or wall) using a laser line projector. The pose of the plane and cameras is then optimized using bundle adjustment to match the lines seen by the cameras. To find the extrinsic calibration, only a partial overlap between the laser lines and the field of view of the cameras is needed. Real-world experiments were conducted both with and without overlapping fields of view, resulting in rotation errors below 0.5°. We show that the accuracy is comparable to other state-of-the-art methods while offering a more practical procedure. The method can also be used in large-scale applications and can be fully automated.