Yongfang Li

Ms. Yongfang Li


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
WWWenjing Wang
Wenjing Wang
ZYZhijian Yi
Zhijian Yi
QLQiongxin Liang
Qiongxin Liang
JZJunjie Zhen
Junjie Zhen
RWRui Wang
Rui Wang
YLYongfang Li
Yongfang Li
In this study, a screen-printed carbon electrode (SPCE) based on in situ deposition modification was developed for the sensitive, rapid, easy and convenient determination of As(III) in water and tea by linear sweep anodic stripping voltammetry (LSASV). The screen-printed carbon electrodes were placed in a solution consisting of As(III) solution, chlorauric acid and L-cysteine. Under certain electrical potential, the chloroauric acid was reduced to gold nanoparticles (AuNPs) on the SPCE. L-cysteine was self-assembled onto AuNPs and promoted the enrichment of As(III), thus enhancing the determination specificity and sensitivity of As(III). The method achieved a limit of determination (LOD) of 0.91 ppb (µg L−1), a linear range of 1~200 µg L−1, an inter-assay coefficient of variation of 5.3% and good specificity. The developed method was successfully applied to the determination of As(III) in tap water and tea samples, with a recovery rate of 93.8%~105.4%, and further validated by inductively coupled plasma mass spectrometry (ICP-MS). The developed method is rapid, convenient and accurate, holding great promise in the on-site determination of As(III) in tap water and tea leaves, and it can be extended to the detection of other samples.

13 May 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
RWRui Wang
Rui Wang
YLYongfang Li
Yongfang Li
YPYanan Pang
Yanan Pang
Fang ZhangFang Zhang
Fang Zhang
FLFuyou Li
Fuyou Li
CQChunyan Qian
Chunyan Qian

4 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YLYongfang Li
Yongfang Li
XCXuan Chen
Xuan Chen
ZYZhiyong Yuan
Zhiyong Yuan
ZYZhijian Yi
Zhijian Yi
梓王梓骏 王
梓骏 王
RWRui Wang
Rui Wang
In this study, nanoporous gold (NPG) was deposited on a screen-printed carbon electrode (SPCE) by the dynamic hydrogen bubble template (DHBT) method to prepare an electrochemical sensor for the simultaneous determination of Pb2+ and Cu2+ by square wave anodic stripping voltammetry (SWASV). The electrodeposition potential and electrodeposition time for NPG/SPCE preparation were investigated thoroughly. Scanning electron microscopy (SEM) and energy-dispersive X-ray diffraction (EDX) analysis confirmed successful fabrication of the NPG-modified electrode. Electrochemical characterization exhibits its superior electron transfer ability compared with bare and nanogold-modified electrodes. After a comprehensive optimization, Pb2+ and Cu2+ were simultaneously determined with linear range of 1–100 μg/L for Pb2+ and 10–100 μg/L for Cu2+, respectively. The limits of detection were determined to be 0.4 μg/L and 5.4 μg/L for Pb2+ and Cu2+, respectively. This method offers a broad linear detection range, a low detection limit, and good reliability for heavy metal determination in drinking water. These results suggest that NPG/SPCE holds great promise in environmental and food applications.

27 September 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
RWRui Wang
Rui Wang
YLYing Liu
Ying Liu
SCShuaiwei Chen
Shuaiwei Chen
LBLinlin Bai
Linlin Bai
KGKaiming Guo
Kaiming Guo
YWYongming Wang
Yongming Wang
Bloodstream infection is a major health problem worldwide, with extremely high mortality. Detecting infection in the early stage is challenging due to the extremely low concentration of bacteria in the blood. Digital PCR provides unparalleled sensitivity and can achieve absolute quantification, but it is time-consuming. Moreover, the presence of unavoidable background signals in negative controls poses a significant challenge for single-molecule detection. Here, we propose a novel strategy called “Ultrafast flexible thin tube-based droplet digital PCR (utPCR)” that can shorten the digital PCR process from 2 h to only 5 min, with primer annealing/extension time reduced from minutes to only 5 s. Importantly, the ultrafast PCR eliminates nonspecific amplification and thus enables single-molecule detection. The utPCR enabled the sensitive detection and digital quantification of E. coli O157 in the high background of a 106-fold excess of E. coli K12 cells. Moreover, this method also displayed the potential to detect rare pathogens in blood samples, and the limit of detection (LOD) could be as low as 10 CFU per mL of blood without false positive results. Considered ultrafast (<5 min) and highly sensitive (single-molecule detection), the utPCR holds excellent prospects in the next generation of molecular diagnosis.

8 May 2026 in Food Microbiology
Verified
Journal Article
Closed access
ZYZhexun Yang
Zhexun Yang
SXSili Xiao
Sili Xiao
XCXuan Chen
Xuan Chen
YLYongfang Li
Yongfang Li
WBWeidong Bai
Weidong Bai
QLQiaoyu Liu
Qiaoyu Liu

6 September 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
RWRui Wang
Rui Wang
YLYing Liu
Ying Liu
SCShuaiwei Chen
Shuaiwei Chen
LBLinlin Bai
Linlin Bai
KGKaiming Guo
Kaiming Guo
YWYongming Wang
Yongming Wang
Bloodstream infection is a major health problem worldwide, with extremely high mortality. Detecting infection in the early stage is challenging due to the extremely low concentration of bacteria in the blood. Digital PCR provides unparalleled sensitivity and can achieve absolute quantification, but it is time-consuming. Moreover, the presence of unavoidable background signals in negative controls poses a significant challenge for single-molecule detection. Here, we propose a novel strategy called “Ultrafast flexible thin tube-based droplet digital PCR (utPCR)” that can shorten the digital PCR process from 2 hours to only 5 minutes, with primer annealing/extension time reduced from minutes to only 5 seconds. Importantly, the ultrafast PCR eliminates the nonspecific amplification and thus enables single-molecular detection. The utPCR enabled sensitive detection and digital quantification of E. coli O157 in the high background of 106-fold excess of E. coli K12 cells. Moreover, this method also displayed the potential to detect rare pathogens in blood samples, and the limit of detection (LOD) could be as low as 10 CFU per mL of blood without false positive results. Considering ultrafast (<5 min) and highly sensitive (single-molecule detection), the utPCR holds excellent prospects in the next generation of molecular diagnosis.