Zhijian Yi

Mr. Zhijian Yi


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
OMOmar Mukama
Omar Mukama
TYTing Yuan
Ting Yuan
ZHZhixu He
Zhixu He
ZLZhiyuan Li
Zhiyuan Li
JHJean de Dieu Habimana
Jean de Dieu Habimana
LZLingwen Zeng
Lingwen Zeng

26 December 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
ZYZhijian Yi
Zhijian Yi
JHJean de Dieu Habimana
Jean de Dieu Habimana
OMOmar Mukama
Omar Mukama
ZLZhiyuan Li
Zhiyuan Li
NONelson Odiwuor
Nelson Odiwuor
LZLingwen Zeng
Lingwen Zeng
Coronavirus disease 2019 (COVID-19) caused by the SARS-CoV-2 virus has led to a global pandemic with a high spread rate and pathogenicity. Thus, with limited testing solutions, it is imperative to develop early-stage diagnostics for rapid and accurate detection of SARS-CoV-2 to contain the rapid transmission of the ongoing COVID-19 pandemic. In this regard, there remains little knowledge about the integration of the CRISPR collateral cleavage mechanism in the lateral flow assay and fluorophotometer. In the current study, we demonstrate a CRISPR/Cas12a-based collateral cleavage method for COVID-19 diagnosis using the Cas12a/crRNA complex for target recognition, reverse transcription loop-mediated isothermal amplification (RT-LAMP) for sensitivity enhancement, and a novel DNA capture probe-based lateral flow strip (LFS) or real-time fluorescence detector as the parallel system readout facility, termed CRICOLAP. Our novel approach uses a customized reporter that hybridizes an optimized complementary capture probe fixed at the test line for naked-eye result readout. The CRICOLAP system achieved ultra-sensitivity of 1 copy/µL in ~32 min by portable real-time fluorescence detection and ~60 min by LFS. Furthermore, CRICOLAP validation using 60 clinical nasopharyngeal samples previously verified with a commercial RT-PCR kit showed 97.5% and 100% sensitivity for S and N genes, respectively, and 100% specificity for both genes of SARS-CoV-2. CRICOLAP advances the CRISPR/Cas12a collateral cleavage result readout in the lateral flow assay and fluorophotometer, and it can be an alternative method for the decentralized field-deployable diagnosis of COVID-19 in remote and limited-resource locations.

12 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
WWWenjing Wang
Wenjing Wang
ZYZhijian Yi
Zhijian Yi
QLQiongxin Liang
Qiongxin Liang
JZJunjie Zhen
Junjie Zhen
RWRui Wang
Rui Wang
YLYongfang Li
Yongfang Li
In this study, a screen-printed carbon electrode (SPCE) based on in situ deposition modification was developed for the sensitive, rapid, easy and convenient determination of As(III) in water and tea by linear sweep anodic stripping voltammetry (LSASV). The screen-printed carbon electrodes were placed in a solution consisting of As(III) solution, chlorauric acid and L-cysteine. Under certain electrical potential, the chloroauric acid was reduced to gold nanoparticles (AuNPs) on the SPCE. L-cysteine was self-assembled onto AuNPs and promoted the enrichment of As(III), thus enhancing the determination specificity and sensitivity of As(III). The method achieved a limit of determination (LOD) of 0.91 ppb (µg L−1), a linear range of 1~200 µg L−1, an inter-assay coefficient of variation of 5.3% and good specificity. The developed method was successfully applied to the determination of As(III) in tap water and tea samples, with a recovery rate of 93.8%~105.4%, and further validated by inductively coupled plasma mass spectrometry (ICP-MS). The developed method is rapid, convenient and accurate, holding great promise in the on-site determination of As(III) in tap water and tea leaves, and it can be extended to the detection of other samples.

12 March 2024 in International Journal of Electrochemical Science
Verified
Journal Article
Open access
XCXuan Chen
Xuan Chen
ZYZhijian Yi
Zhijian Yi
GPGuoxin Peng
Guoxin Peng
ZYZhiyong Yuan
Zhiyong Yuan
RWRui Wang
Rui Wang
YLYongfang Li
Yongfang Li

4 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YLYongfang Li
Yongfang Li
XCXuan Chen
Xuan Chen
ZYZhiyong Yuan
Zhiyong Yuan
ZYZhijian Yi
Zhijian Yi
梓王梓骏 王
梓骏 王
RWRui Wang
Rui Wang
In this study, nanoporous gold (NPG) was deposited on a screen-printed carbon electrode (SPCE) by the dynamic hydrogen bubble template (DHBT) method to prepare an electrochemical sensor for the simultaneous determination of Pb2+ and Cu2+ by square wave anodic stripping voltammetry (SWASV). The electrodeposition potential and electrodeposition time for NPG/SPCE preparation were investigated thoroughly. Scanning electron microscopy (SEM) and energy-dispersive X-ray diffraction (EDX) analysis confirmed successful fabrication of the NPG-modified electrode. Electrochemical characterization exhibits its superior electron transfer ability compared with bare and nanogold-modified electrodes. After a comprehensive optimization, Pb2+ and Cu2+ were simultaneously determined with linear range of 1–100 μg/L for Pb2+ and 10–100 μg/L for Cu2+, respectively. The limits of detection were determined to be 0.4 μg/L and 5.4 μg/L for Pb2+ and Cu2+, respectively. This method offers a broad linear detection range, a low detection limit, and good reliability for heavy metal determination in drinking water. These results suggest that NPG/SPCE holds great promise in environmental and food applications.