Hariharan Nhalil

Dr. Hariharan Nhalil


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2015 in Physical Review B
Verified
Journal Article
Open access
PDF file
HNHariharan Nhalil
Hariharan Nhalil
HNHarikrishnan S. Nair
Harikrishnan S. Nair
CKC. M. N. Kumar
C. M. N. Kumar
ASAndre Strydom
Andre Strydom
SESuja Elizabeth
Suja Elizabeth
The double perovskite Y2NiMnO6 displays ferromagnetic transition at Tc≈81 K. The ferromagnetic order at low temperature is confirmed by the saturation value of magnetization (Ms) and also validated by the refined ordered magnetic moment values extracted from neutron powder diffraction data at 10 K. This way, the dominant Mn4+ and Ni2+ cationic ordering is confirmed. The cation-ordered P21/n nuclear structure is revealed by neutron powder diffraction studies at 300 and 10 K. Analysis of the frequency-dependent dielectric constant and equivalent circuit analysis of impedance data take into account the bulk contribution to the total dielectric constant. This reveals an anomaly which coincides with the ferromagnetic transition temperature (Tc). Pyrocurrent measurements register a current flow with onset near Tc and a peak at 57 K that shifts with temperature ramp rate. The extrinsic nature of the observed pyrocurrent is established by employing a special protocol measurement. It is realized that the origin is due to reorientation of electric dipoles created by the free charge carriers and not by spontaneous electric polarization at variance with recently reported magnetism-driven ferroelectricity in this material.

19 November 2015 in ACS Nano
Verified
Journal Article
Closed access
SBSemonti Bhattacharyya
Semonti Bhattacharyya
MBMitali Banerjee
Mitali Banerjee
HNHariharan Nhalil
Hariharan Nhalil
SISaurav Islam
Saurav Islam
CDChandan Dasgupta
Chandan Dasgupta
AGArindam Ghosh
Arindam Ghosh

28 December 2020 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
HNHariharan Nhalil
Hariharan Nhalil
Proloy Taran DasProloy Taran Das
Proloy Taran Das
MSMoty Schultz
Moty Schultz
SAShai Amrusi
Shai Amrusi
AGAsaf Grosz
Asaf Grosz
LIOR KLEINLIOR KLEIN
LIOR KLEIN
We fabricate elliptical planar Hall effect magnetometers with Permalloy thickness ranging between 25 and 200 nm. We study the thickness dependence of their equivalent magnetic noise by examining the effect of the layer thickness on the signal and noise including Joule heating contributions. Sensors with a thickness of 50 nm achieve equivalent magnetic noise as low as ∼24 pT/ √ Hz at 50 Hz and ∼36 pT/ √ Hz at 10 Hz, which are the best reported values for any type of magnetic sensor of similar or smaller size. These results are achieved without the use of magnetic flux concentrators, which helps to reduce the sensor volume while improving its spatial resolution and reducing the complexity and time of its production and, hence, its potential cost. We discuss different routes for further resolution improvements.

1 May 2018 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
HNHariharan Nhalil
Hariharan Nhalil
DHDan Han
Dan Han
MDMao-Hua Du
Mao-Hua Du
SCShiyou Chen
Shiyou Chen
DADaniel Antonio
Daniel Antonio
BSBayrammurad Saparov
Bayrammurad Saparov

2 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
HNHariharan Nhalil
Hariharan Nhalil
Moty SchultzMoty Schultz
Moty Schultz
SAShai Amrusi
Shai Amrusi
AGAsaf Grosz
Asaf Grosz
LIOR KLEINLIOR KLEIN
LIOR KLEIN
We report a specially designed magnetic field gradiometer based on a single elliptical planar Hall effect (PHE) sensor, which allows measuring magnetic field at nine different positions in a 4 mm length scale. The gradiometer detects magnetic field gradients with equivalent gradient magnetic noises of ∼958, ∼192, ∼51, and ∼26 nT/m√ Hz (pT/mm√Hz) at 0.1, 1, 10, and 50 Hz, respectively. The performance of the gradiometer is tested in ambient conditions by measuring the field gradient induced by electric currents driven in a long straight wire. This gradiometer is expected to be highly useful for the measurement of magnetic field gradients in confined areas for its small footprint, low noise, scalability, simple design, and low costs.

22 May 2023 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
HNHariharan Nhalil
Hariharan Nhalil
Moty SchultzMoty Schultz
Moty Schultz
SAShai Amrusi
Shai Amrusi
AGAsaf Grosz
Asaf Grosz
LIOR KLEINLIOR KLEIN
LIOR KLEIN
We introduce a planar Hall effect magnetometer in the form of a parallel array of permalloy-based elliptical sensors. The number of ellipses in the array and other fabrication parameters are optimized with the support of numerical simulations. We obtain equivalent magnetic noise (EMN) of 16 pT/Hz at 100 Hz, 25 pT/Hz at 10 Hz, 98 pT/Hz at 1 Hz, and 470 pT/Hz at 0.1 Hz. The exceptional EMN without the use of magnetic flux concentrators highlights the advantages of the design. The presented magnetometer, characterized by its simplicity, affordability, and ability to operate at room temperature, is anticipated to be useful for applications requiring pT resolution.