Asaf Grosz

Dr. Asaf Grosz


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2019 in IEEE Sensors Letters
Verified
Journal Article
Closed access
HNHariharan Nhalil
Hariharan Nhalil
TGTzahi Givon
Tzahi Givon
Proloy Taran DasProloy Taran Das
Proloy Taran Das
NHNir Hasidim
Nir Hasidim
VMVladislav Mor
Vladislav Mor
AGAsaf Grosz
Asaf Grosz

28 December 2020 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
HNHariharan Nhalil
Hariharan Nhalil
Proloy Taran DasProloy Taran Das
Proloy Taran Das
MSMoty Schultz
Moty Schultz
SAShai Amrusi
Shai Amrusi
AGAsaf Grosz
Asaf Grosz
LIOR KLEINLIOR KLEIN
LIOR KLEIN
We fabricate elliptical planar Hall effect magnetometers with Permalloy thickness ranging between 25 and 200 nm. We study the thickness dependence of their equivalent magnetic noise by examining the effect of the layer thickness on the signal and noise including Joule heating contributions. Sensors with a thickness of 50 nm achieve equivalent magnetic noise as low as ∼24 pT/ √ Hz at 50 Hz and ∼36 pT/ √ Hz at 10 Hz, which are the best reported values for any type of magnetic sensor of similar or smaller size. These results are achieved without the use of magnetic flux concentrators, which helps to reduce the sensor volume while improving its spatial resolution and reducing the complexity and time of its production and, hence, its potential cost. We discuss different routes for further resolution improvements.

5 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DLDaniel Lahav
Daniel Lahav
Moty SchultzMoty Schultz
Moty Schultz
SAShai Amrusi
Shai Amrusi
AGAsaf Grosz
Asaf Grosz
LIOR KLEINLIOR KLEIN
LIOR KLEIN
The magnetic field range in which a magnetic sensor operates is an important consideration for many applications. Elliptical planar Hall effect (EPHE) sensors exhibit outstanding equivalent magnetic noise (EMN) on the order of pT/Hz, which makes them promising for many applications. Unfortunately, the current field range in which EPHE sensors with pT/Hz EMN can operate is sub-mT, which limits their potential use. Here, we fabricate EPHE sensors with an increased field range and measure their EMN. The larger field range is obtained by increasing the uniaxial shape-induced anisotropy parallel to the long axis of the ellipse. We present measurements of EPHE sensors with magnetic anisotropy which ranges between 12 Oe and 120 Oe and show that their EMN at 10 Hz changes from 800 pT/Hz to 56 nT/Hz. Furthermore, we show that the EPHE sensors behave effectively as single magnetic domains with negligible hysteresis. We discuss the potential use of EPHE sensors with extended field range and compare them with sensors that are widely used in such applications.

22 December 2020 in IEEE Sensors Letters
Verified
Journal Article
Closed access
Proloy Taran DasProloy Taran Das
Proloy Taran Das
HNHariharan Nhalil
Hariharan Nhalil
MSMoty Schultz
Moty Schultz
SAShai Amrusi
Shai Amrusi
AGAsaf Grosz
Asaf Grosz
LIOR KLEINLIOR KLEIN
LIOR KLEIN
Using planar Hall effect sensors with magnetic flux concentrators, we measure magnetic fields at frequencies below 100 Hz. We show that for a measurement time of up to 100 s, it is possible to detect fields of ∼700 fT and ∼1 pT at 10 Hz and 0.1 Hz, respectively. In addition, we measure the linearity and hysteresis of the sensor for fields ≤2.6 μ T. These features, combined with the sensor miniature size, low power consumption, and potential low cost, may pave the way for usage in a wide range of applications.

2 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
HNHariharan Nhalil
Hariharan Nhalil
Moty SchultzMoty Schultz
Moty Schultz
SAShai Amrusi
Shai Amrusi
AGAsaf Grosz
Asaf Grosz
LIOR KLEINLIOR KLEIN
LIOR KLEIN
We report a specially designed magnetic field gradiometer based on a single elliptical planar Hall effect (PHE) sensor, which allows measuring magnetic field at nine different positions in a 4 mm length scale. The gradiometer detects magnetic field gradients with equivalent gradient magnetic noises of ∼958, ∼192, ∼51, and ∼26 nT/m√ Hz (pT/mm√Hz) at 0.1, 1, 10, and 50 Hz, respectively. The performance of the gradiometer is tested in ambient conditions by measuring the field gradient induced by electric currents driven in a long straight wire. This gradiometer is expected to be highly useful for the measurement of magnetic field gradients in confined areas for its small footprint, low noise, scalability, simple design, and low costs.

21 September 2016
Verified
Book Chapter
Closed access
PDF file
VMVladislav Mor
Vladislav Mor
AGAsaf Grosz
Asaf Grosz
LKLior Klein
Lior Klein